Inicio  /  Buildings  /  Vol: 13 Par: 8 (2023)  /  Artículo
ARTÍCULO
TITULO

Study on the Performance of a New Ultra-Low Temperature Air Source Heat Pump (ASHP) Unit in Cold Regions

Yanqiang Di    
Chen Zhao    
Xueli Lian    
Xiaolong Li    
Daorina Bao and Jinxing Liu    

Resumen

Low air temperature and frosting have been reported as the critical factors that greatly attenuate the efficiency and performance of the ASHP in cold regions. In order to ensure the potential prevalence of the ASHP in cold regions of China, a new ultra-low temperature ASHP unit was developed, and the field measurement was carried out in an office building where these ASHP units were installed in Shanxi Province. Results showed that a coefficient of performance (COP) of 1.83 was obtained at the ultra-low environmental temperature of -25 °C. Meanwhile, measured results indicated significant frosting suppression and improved heating performance under three typical frosting conditions. In addition, long-term measurement results revealed that the mean COP and COPsys reached up to 3.34 and 2.63, respectively, indicating a higher performance in the cold regions of China. Consequently, the corresponding CO2 emission reached 11.3 kg per year and per square meter, and the annual total cost on the unit reduced by 15.8% compared with the conventional ASHP, which meant that the total investment could be covered in the second year. The reduced CO2 emission and the annual cost implied that the ASHP unit could produce better environmental and economic benefits. Findings of this study revealed that this ultra-low temperature ASHP unit had a better performance under cold environment, which offered a possibility for the prevailing of the ASHP in cold or extremely cold regions, as well as could contribute to the carbon peaking and neutralization.

 Artículos similares

       
 
Rick Jaeger, Carolyn Jacobs, Katharina Tondera and Neil Tindale    
This study investigated different approaches to optimize flows in misaligned culverts. Structures aligned with the natural stream are always preferred, as misalignments cause a change of direction at the culvert inlet associated with lower performance an... ver más
Revista: Water

 
Margarita Garcia-Vila, Rodrigo Morillo-Velarde and Elias Fereres    
Process-based crop models such as AquaCrop are useful for a variety of applications but must be accurately calibrated and validated. Sugar beet is an important crop that is grown in regions under water scarcity. The discrepancies and uncertainty in past ... ver más
Revista: Water

 
Zuhang Wu, Yun Zhang, Lifeng Zhang, Xiaolong Hao, Hengchi Lei and Hepeng Zheng    
In this study, we evaluated the performance of rain-retrieval algorithms for the Version 6 Global Precipitation Measurement Dual-frequency Precipitation Radar (GPM DPR) products, against disdrometer observations and improved their retrieval algorithms by... ver más
Revista: Water

 
Peter Jarvis, Olivier Autin, Emma H. Goslan and Francis Hassard    
Ultraviolet light-emitting diodes (UV-LEDs) have recently emerged as a viable technology for water disinfection. However, the performance of the technology in full-scale drinking-water treatment systems remains poorly characterised. Furthermore, current ... ver más
Revista: Water

 
Bingjian Cui and Shengxian Liang    
Wastewater reuse for agricultural irrigation in many developing countries is an increasingly common practice. Regular monitoring of indicators can help to identify potential health risks; therefore, there is an urgent need to understand the presence and ... ver más
Revista: Water