Inicio  /  Buildings  /  Vol: 5 Par: 2 (2015)  /  Artículo
ARTÍCULO
TITULO

Assessment of the Potential to Achieve very Low Energy Use in Public Buildings in China with Advanced Window and Shading Systems

Eleanor S. Lee    
Xiufeng Pang    
Andrew McNeil    
Sabine Hoffmann    
Anothai Thanachareonkit    
Zhengrong Li and Yong Ding    

Resumen

As rapid growth in the construction industry continues to occur in China, the increased demand for a higher standard living is driving significant growth in energy use and demand across the country. Building codes and standards have been implemented to head off this trend, tightening prescriptive requirements for fenestration component measures using methods similar to the U.S. model energy code American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) 90.1. The objective of this study is to (a) provide an overview of applicable code requirements and current efforts within China to enable characterization and comparison of window and shading products, and (b) quantify the load reduction and energy savings potential of several key advanced window and shading systems, given the divergent views on how space conditioning requirements will be met in the future. System-level heating and cooling loads and energy use performance were evaluated for a code-compliant large office building using the EnergyPlus building energy simulation program. Commercially-available, highly-insulating, low-emittance windows were found to produce 24%?66% lower perimeter zone HVAC electricity use compared to the mandated energy-efficiency standard in force (GB 50189-2005) in cold climates like Beijing. Low-e windows with operable exterior shading produced up to 30%?80% reductions in perimeter zone HVAC electricity use in Beijing and 18%?38% reductions in Shanghai compared to the standard. The economic context of China is unique since the cost of labor and materials for the building industry is so low. Broad deployment of these commercially available technologies with the proper supporting infrastructure for design, specification, and verification in the field would enable significant reductions in energy use and greenhouse gas emissions in the near term.

Palabras claves

 Artículos similares

       
 
Bojana Petrovic, Ola Eriksson, Xingxing Zhang and Marita Wallhagen    
Previous research has shown a lack of studies with comparisons between primary (virgin) and secondary (re-used) building materials, and their embodied emissions. The creation of different scenarios comparing the environmental impact of virgin vs. re-used... ver más
Revista: Buildings

 
Vanessa Gonçalves, Antonio Albuquerque, Pedro Gabriel Almeida, Luís Ferreira Gomes and Victor Cavaleiro    
The risk of aquifer contamination is determined by the interaction between the pollutant load and the vulnerability of an aquifer. Owing to the decomposition of bodies and degradation of artefacts, cemeteries may have a negative impact on groundwater qua... ver más
Revista: Water

 
Xiaorong Wang, Boyue Liu, Shaolin He, Hongying Yuan, Dongli Ji, Ruolin Li, Yang Song, Wei Xu, Bo Liu and Yingjun Xu    
To clarify the risk posed to groundwater in oil shale in situ mining areas, we examine five leached pollutants: Fe, Mn, Cr, sulfate, and ammonia nitrogen. Potential groundwater contents of these five pollutants were evaluated using an improved Nemero com... ver más
Revista: Water

 
Filippo Dolente, Rosario Giuseppe Garroppo and Michele Pagano    
The paper presents an experimental security assessment within two widely used open-source 5G projects, namely Open5GS and OAI (Open-Air Interface). The examination concentrates on two network functions (NFs) that are externally exposed within the core ne... ver más
Revista: Future Internet

 
Jhon B. Valencia, Vladimir V. Guryanov, Jeison Mesa-Diez, Nilton Diaz, Daniel Escobar-Carbonari and Artyom V. Gusarov    
This paper presents a hydrological assessment of the 113,981 km2 Meta River basin in Colombia using 13 global climate models to predict water yield for 2050 under two CMIP6 scenarios, SSP 4.5 and SSP 8.5. Despite mixed performance across subbasins, the m... ver más
Revista: Hydrology