Inicio  /  Buildings  /  Vol: 13 Par: 8 (2023)  /  Artículo
ARTÍCULO
TITULO

Experimental Investigation of Shear Behavior in High-Strength Concrete Beams Reinforced with Hooked-End Steel Fibers and High-Strength Steel Rebars

Amirhassan Alizadeh    
Taleb Moradi Shaghaghi    
Masoud Pourbaba    
Seyed Saeed Mirrezaei and Yousef Zandi    

Resumen

Shear failure is an unfavorable phenomenon as it is a brittle type of failure; however, adding rebars and fibers to a concrete beam can minimize its detrimental effects. The objective of this study was to experimentally investigate the shear behavior of high-strength concrete (HC) beams reinforced with hooked-end (H) steel fibers and high-strength steel (HS) rebars under three-point bending tests. For this purpose, nine HC beams (300 × 250 × 1150 mm in dimension) were cast with 0%, 1%, and 2% H fibers by volume in three longitudinal rebar ratios (i.e., 1.5%, 2.0%, and 3.1%) and compared with beams without fibers. Furthermore, numerical analyses were performed to validate the experimental results and compare them with design codes. The results showed that, irrespective of the fiber content or longitudinal rebar ratio, the beams failed in shear. Increasing the rebar ratio and fiber content increased the shear capacity to as high as 100% (for the specimen with 3% rebar and 2% fiber compared to its counterpart with 1% rebar and 2% fiber). In addition, the research-based equations proposed in the literature either overestimated or underestimated the shear capacity of fibrous HC beams significantly. The level of overestimation or underestimation was closely related to the sensitivity of the proposed model to the shear span ratio and the fiber content. Rebars proved to be more beneficial in contributing to the shear capacity, but the rate of this positive contribution decreased as the fiber ratio increased. Finally, the inverse analysis approach adopted herein proved to be an efficient tool in estimating the shear response of fiber-reinforced beams failing in shear (margin of error: less than 10%).

 Artículos similares

       
 
Zhenhua Ren, Hui Wang, Lizheng Fang, Peng Ding and Xiantao Zeng    
Stainless steel has the characteristics of oxidation resistance, high temperature resistance, corrosion resistance, high strength, and high yield ratio. The use of stainless steel bars can extend the life of a structure, reduce later maintenance costs, a... ver más
Revista: Buildings

 
Zhi-Jian Zhang, Bai-Sen Chen, Rui Bai and Yao-Peng Liu    
The high strength and stiffness-to-weight ratios of structural steel often result in relatively slender members and systems, which are governed to a great extent by stability limit states. However, predicting the stability of slender structures is diffic... ver más
Revista: Buildings

 
Pengfei Du, Xi Zhao, Zhidong Zhang, Xiaoyan Sun and Gang Du    
Cold-formed steel (CFS) structures are widely used in construction and infrastructure due to their lightweight and high-strength properties. However, their thin-walled nature makes them geometrically sensitive to compressive loading. The Digital Twin (DT... ver más
Revista: Buildings

 
Lin Li, Dejun Mu, Yong Liu, Zhaowei Li, Qixiang Yin and Hongfei Chang    
With the development of blind bolts that can be installed from the outer side of a section, the application of steel pipe hollow sections in prefabricated structures has become possible. The novel one-side bolt with a flip-top collapsible washer (FTW-OSB... ver más
Revista: Buildings

 
Guiwen Liu, Jie Liu, Neng Wang, Xuanyi Xue and Youjia Tan    
Fire has significant effects on the residual resistance of steel structures. It is necessary to accurately clarify its effects on Q690 HSS plate girders, which have been widely used. In this paper, the ultimate resistance and effective service resistance... ver más
Revista: Buildings