Inicio  /  Applied Sciences  /  Vol: 13 Par: 14 (2023)  /  Artículo
ARTÍCULO
TITULO

Test?Retest Reliability and Minimal Detectable Change in Chester Step Test and 1-Minute Sit-to-Stand Test in Long COVID Patients

Ana Isabel Sevillano-Castaño    
Renata Peroy-Badal    
Rodrigo Torres-Castro    
Ana María Cañuelo-Márquez    
Manuel Rozalén-Bustín    
Ángel Modrego-Navarro    
Luis De Sousa-De Sousa    
Juan José Ramos-Álvarez    
José Luis Maté-Muñoz and Pablo García-Fernández    

Resumen

The COVID-19 is a multiorgan disease that appeared in December 2019 in the Chinese province of Wuhan. It produces various clinical manifestations, although it mainly affects the respiratory system. Given these potentially detrimental long-term consequences of COVID-19, an appropriate assessment must be carried out to plan early rehabilitation interventions. To assess the persistent symptoms it produces, as well as exercise tolerance for a given exertion, stress testing is a feasible and cost-effective option. Therefore, the objective of this study was to provide test-retest reliability for the Chester Step Test and 1 minute Sit to Stand tests and to establish the minimum detectable change in Long-COVID patients. Method: This observational, descriptive, cross-sectional study was conducted following the STROBE guidelines. A total of 42 patients carried out, twice per partici-pant, the Chester Step and 1-Minute Sit-to-Stand (1min-STST) tests on two different days, with a five-day time lag between the initial measurement and the second measurement. Results: The Test-retest reliability for the Chester Step was excellent within session ICC (95% CI) 0.96 (0.93 to 0.98), being even better for the 1-STST, ICC (95% CI) 0.98 (0.96 to 0.99). Establishing a change of at least 16.96 steps (MDC90) or 20.15 steps (MDC95) and 1.89 stands (MDC90) or 2.71 stands (MDC95), respectively. Conclusions: The Chester Step and 1min-STST tests are reproducible and reliable tools to measure exercise tolerance in long COVID patients. The minimum detectable changes observed in the values recorded by the participants can be very useful for the evaluation of the effectiveness of interventions applied to these patients.

 Artículos similares

       
 
Jiayu Huang, Feng Diao, Shifeng Ding, Sen Han, Pentti Kujala and Li Zhou    
In previous studies of ship?ice interactions, most studies focused on ship?level ice interactions, overlooking potential rafted ice conditions in extreme ice conditions. The purpose of this study is to develop a numerical model for predicting ship resist... ver más
Revista: Water

 
Sajjad E. Rasheed, Duaa Al-Jeznawi, Musab Aied Qissab Al-Janabi and Luís Filipe Almeida Bernardo    
The structural stability of pipe pile foundations under seismic loading stands as a critical concern, demanding an accurate assessment of the maximum settlement. Traditionally, this task has been addressed through complex numerical modeling, accounting f... ver más

 
Murat Gulen and Havvanur Kilic    
In this study, full-scale laboratory tests were conducted on a 315 mm diameter HDPE pipe under shallow buried and localised surface loading conditions to investigate the effects of pipe deflection and arching on stress distribution and the lateral earth ... ver más
Revista: Applied Sciences

 
Radvan Bahbouh, Eva Hoschlova, Michal Huzva and Katerina Bernardova Sykorova    
(1) Background: Starting in 1993, the sociomapping method was used in the Czech Army to map communication. After initial pilot tests in military aviation, where we verified the reliability and validity of the basic subjective scales (for example, by corr... ver más
Revista: Aerospace

 
Yusong Wang, Chengxiang Zhu, Ke Xiong and Chunling Zhu    
Ice accumulation on airfoils and engines seriously endangers fight safety. The design of anti-icing/de-icing systems calls for an accurate measurement of the adhesion strength between ice and substrates. In this research, a test bench for adhesion streng... ver más
Revista: Aerospace