Inicio  /  Applied Sciences  /  Vol: 11 Par: 12 (2021)  /  Artículo
ARTÍCULO
TITULO

Study on the Combined Effect of Multiple Passive Energy-Saving Methods for Rural Houses with Cold Alleys

Xingbo Yao    
Shuo Han and Bart Julien Dewancker    

Resumen

China?s rural houses are mostly courtyard-style independent houses. Such houses have certain characteristics, e.g., small mutual influences between houses, strong transformation flexibility, and an easier approach to using the natural environment to develop passive energy-saving characteristics. Therefore, rural houses have large energy-saving potential. In this study, for the first time, the cold alleys between buildings were used as an energy source for passive cooling and ventilation. Traditional houses in Shuhe, China, were used as a case study. The cold alleys in the settlements were used to compensate for the natural conditions in summer, and the cold air in the cold alley was introduced into each room using hot-press ventilation and by employing an accumulation effect from a corresponding patio. The room was ventilated and cooled, and air ducts were used to connect the rooms on both sides of the patio to improve the cooling efficiency. The research variables included the existence or non-existence of wall heat radiation (WHR), and the importance and influence of the WHR on the indoor conditions were verified. The cold air trapped in the new system formed an air partition wall, effectively blocking the direct influence of solar radiation on the room, reducing the heat transfer rate of the residential wall, and consuming part of the heat. In winter, based on using air ducts as supporting members, a glass roof was added to the patio, which improved the heat storage capacity of the patio and turned it into a constant-temperature heater for heating the building interior. Based on calculations, in the new system without WHR, the annual cooling load reduction was 55,417.33 kWh. With WHR, the annual cooling load reduction was 28,537.57 kWh. The annual cooling load of the air insulation wall of the new system was reduced to 1133.7 kWh. In winter, using the glass roof to increase the heat storage capacity of the patio reduced the heating load to 54,537.78 kWh.

 Artículos similares

       
 
Gulsum Alicioglu and Bo Sun    
Deep learning (DL) models have achieved state-of-the-art performance in many domains. The interpretation of their working mechanisms and decision-making process is essential because of their complex structure and black-box nature, especially for sensitiv... ver más
Revista: AI

 
Yi Zhang, Hengchao Zhao, Zheng Zhang and Hongbo Wang    
Addressing the automatic berthing task for vessels, this study introduces the Flow Matching Double Section Bezier Berth Method (FM-DSB) for handling downstream and upstream berthing instructions. By considering the orientation relationship between the di... ver más

 
Bocheng Zhao, Mingying Huo, Ze Yu, Naiming Qi and Jianfeng Wang    
In this study, we propose an aerial rendezvous method to facilitate the recovery of unmanned aerial vehicles (UAVs) using carrier aircrafts, which is an important capability for the future use of UAVs. The main contribution of this study is the developme... ver más
Revista: Aerospace

 
Rong Wang, Xinyang Zhou, Yi Liu, Dongqi Liu, Yu Lu and Miao Su    
To ensure the safety and durability of concrete structures, timely detection and classification of concrete cracks using a low-cost and high-efficiency method is necessary. In this study, a concrete surface crack damage detection method based on the ResN... ver más
Revista: Applied Sciences

 
Andjelka Simic, Mirjana V. Papic, Ana Nikitovic, Aleksandar Kocovic, Renata Petrovic, Irena Melih, Suzana Zivanovic, Milos Papic and Milica Popovic    
This study investigates the pH values and optical characteristics of Dual Rinse HEDP, either independently or combined with sodium hypochlorite (NaOCl), and compares them to other irrigants used in endodontics. The solutions used in this study were comme... ver más
Revista: Applied Sciences