Inicio  /  Buildings  /  Vol: 12 Par: 9 (2022)  /  Artículo
ARTÍCULO
TITULO

Monitoring Axial Force Development in a Super-Long Pile during Construction Using BOFDA and Data Interpretation Approaches: A Case Study

Dongning Li    
Deshan Ma    
Dong Su    
Shaohua Rao    
Wenbin Wang and Chengyu Hong    

Resumen

Long-term monitoring data for super-long piles are scarce and valuable. This paper reports axial strain measurements of a cast-in-place large-diameter pile embedded 76.7 m into a ?weathered trench? of granite in Nanshan District, Shenzhen, China, using BOFDA monitoring technology. An approach based on the load-transfer method to interpret data is proposed, in which the axial load at the pile head and the shear behavior at the pile?soil interface can be analyzed. Results show that these data can well reflect the increase in axial strain as the number of floors built increases, although there is deviation related to fiber cable bending due to the installation and compaction of concrete, and the complex loading condition at the pile head. Sensitivity analysis of parameters disclosed that the friction angle between the soil and the pile was approximately 10° for the cast-in-place pile monitored in this study, which is approximately one third of the interface friction angle, considering the slurry cake effect. The average axial force exerted on the pile head induced by building one floor ranged from 116.00 kN to 297.43 kN; this increased with the number of floors built and the total loads of the superstructure. This implies that the raft carried a large portion of the structural load during the early construction stage; piles gradually carried a major portion of the increased load due to continuous construction. The overall mobilized percentage of skin friction was approximately 40.8% when 40 floors were built, and the pile had the potential to carry more axial load.

 Artículos similares

       
 
Marco Bonopera    
Stress state evaluation in axially loaded structural members is significant for sustaining and preserving the service life of buildings. While successful monitoring furnishes staunch information on the health, integrity, safety and serviceability of stru... ver más
Revista: Buildings

 
Lin Sun, Ke Mao, Zhengzhen Wang, Shuaihua Ye, Tiantao Su, Guoliang Dai, Guangxiang Xu and Jilong Sun    
With the continuous development of urbanization and the rapid development of science and technology, the requirements for foundation pit engineering are getting higher and higher. Foundation pit engineering is gradually developing in the direction of lar... ver más
Revista: Water

 
Hanzlah Akhlaq, Faheem Butt, Mamdooh Alwetaishi, Mamoon Riaz, Omrane Benjeddou and Enas E. Hussein    
This paper presents the operational modal analysis of a 90-m-high RC minaret of an iconic mosque considered as a landmark of the city. The minaret was monitored for three days with 11 tri-axial MEMS accelerometers. The purpose of the study was to observe... ver más
Revista: Buildings

 
Takashi Ando    
Mechanically robust turbine design with respect to blade vibration is challenging when dealing with nozzle-ring fouling and wear. Especially for engines operating with heavy fuel oil (HFO), the nozzle rings of the turbocharger turbines are prone to sever... ver más

 
Fan-Yun Pai, Tsu-Ming Yeh and Yung-Hsien Hung    
To consistently produce high quality products, a quality management system, such as the ISO9001, 2000 or TS 16949 must be practically implemented. One core instrument of the TS16949 MSA (Measurement System Analysis) is to rank the capability of a measure... ver más
Revista: Sustainability