Diagnosis of Noise Inside Neonatal Incubators under Free-Field Conditions

Francisco Fernández-Zacarías    
Juan Luis Beira-Jiménez    
Virginia Puyana-Romero and Ricardo Hernández-Molina    

Resumen

The study aims to diagnose the sound pressure levels inside incubators in a controlled environment under free-field conditions. The tests were carried out in a semi-anechoic room under the standard UNE-EN ISO 3745:2012/A1:2018 in three different operating states: off, on, and on with a temperature alarm triggered. Sound pressure levels were analyzed in three different models of incubators, both inside and outside. The main noise indices analyzed were the corrected equivalent continuous level (LKeq) and the equivalent continuous level (Leq) in third-octave bands. The results obtained under normal operating conditions showed variations among the different incubators, with overall values between 48.8 and 56.3 dBA. The influence of the alarm considerably worsened these data. The values obtained showed that premature newborns are exposed to noise levels above international recommendations. All incubators tested showed the presence of tonal components, both outside and inside the incubator cabin, and, in some cases, low-frequency components, but no impulsivity components were observed in any case.

 Artículos similares

       
 
Oksana Kharchenko, Zlatinka Kovacheva and Velin Andonov    
Ensuring noise immunity is one of the main tasks of radio engineering and telecommunication. The main task of signal receiving comes down to the best recovery of useful information from a signal that is destructed during propagation and received together... ver más
Revista: Applied Sciences

 
Chan-Sol Park, Soo-Jin Ahn, Yeong-Bae Lee and Chang-Ki Kang    
In ultrasound diagnostics, acoustic absorbers block unwanted acoustic energy or prevent the reception of echo signals from structures outside the target area. Non-metallic absorbers provide a low-echoic signal that is suitable for observing the anatomy o... ver más
Revista: Applied Sciences

 
Ping-Chang Tsai, Yu-Min Hsueh, Chang-Kuo Chen and Cheng-Chien Kuo    
Partial discharge (PD) characteristics are very important for the diagnosis of damaged transformation equipment. If the power transmission and transformation equipment fails, it will cause large economic losses, and thus prevention is better than treatme... ver más
Revista: Applied Sciences

 
Seweryn Lipinski    
DSC-MRI examination is one of the best methods of diagnosis for brain diseases. For this purpose, the so-called perfusion parameters are defined, of which the most used are CBF, CBV, and MTT. There are many approaches to determining these parameters, but... ver más
Revista: Computation

 
Eduardo Morales-Vargas, Hayde Peregrina-Barreto, Rita Q. Fuentes-Aguilar, Juan Pablo Padilla-Martinez, Wendy Argelia Garcia-Suastegui and Julio C. Ramirez-San-Juan    
Microvasculature analysis is an important task in the medical field due to its various applications. It has been used for the diagnosis and threat of diseases in fields such as ophthalmology, dermatology, and neurology by measuring relative blood flow or... ver más
Revista: Information