Inicio  /  Applied Sciences  /  Vol: 12 Par: 12 (2022)  /  Artículo
ARTÍCULO
TITULO

Wear Analysis of Four Different Single-File Reciprocating Instruments before and after Four Uses in Simulated Root Canals

Alessio Zanza    
Rodolfo Reda    
Giuseppe Familiari    
Stefania Annarita Nottola    
Dario Di Nardo    
Luca Testarelli and Orlando Donfrancesco    

Resumen

The aim of this study is to assess the surface alterations of four reciprocating instruments before and after the shaping of four resin-simulated root canals. The following four different reciprocating instruments are selected: 10 Reciproc Blue (RB25), 10 WaveOne Gold (WOG), 10 EdgeOne Fire (EOF) and 10 recently introduced instruments OneRECI (OR), for a total of 40 new instruments. Before root canal shaping, each instrument is mounted on a stub in a standardized position and observed using a scanning electron microscope (SEM) to detect any surface alteration, such as microfractures, metal defects, deformations, blunt and disruption of cutting edges, debris, pitting and tip flattening. Micrographs are acquired at the level of the tip, 4 mm, 8 mm and 12 mm from it. After that, each instrument is used in four simulated resin root canals. SEM observation was repeated after the simulated clinical use to assess the wear resistance of the instruments. Surface alterations are registered before and after instrumentation and statistical analysis is performed using a Chi-Square test to verify homogeneity of defects distribution and GLM to evaluate the differences of RMS at baseline and after use for both groups (a level 0.05). Before simulated clinical uses, no alterations are found except for three cases of EOF with metal strips in correspondence to the tip, disruption of the cutting edge of WOG and oily spotting on two different OR. After simulated clinical use, EOF shows a statistically significant difference in terms of spiral distortion and flattening of the cutting edges. The OR shows the highest presence of debris despite the ultrasonic cleaning procedures. No instrument fractures are observed. EOF should be discarded after four clinical uses and carefully inspected after each insertion into root canals. Moreover, tough attention should be paid during disinfection and cleaning procedures after instrumentation considering the copious debris detected in each instrument, particularly in OR.

 Artículos similares

       
 
Zhimin Yang, Xiangzhao Yan, Yutong Tian, Zaohong Pu, Yihan Wang, Chunhui Li, Yujun Yi, Xuan Wang and Qiang Liu    
The issue of sudden water pollution resulting from accidents is a challenging environmental problem to address. The frequency of transport accidents involving hazardous materials over tributary bridges is steadily rising due to rapid industrialization an... ver más
Revista: Water

 
Sergio Alexandre Gehrke, Berenice Anina Dedavid, Germán Odella Colla, Piedad N. De Aza and Leticia Pérez-Díaz    
(1) Background: The present pilot in vitro study evaluated, physically and biologically, the effects produced by the wear of the titanium surface using different drill models. (2) Methods: Titanium disks were subjected to wear using four different burs a... ver más
Revista: Applied Sciences

 
Dongxu Yang, Yong You, Wanyu Zhao, Hai Huang, Hao Sun and Yang Liu    
Debris flow gullies have high potential energy and geomorphic characteristics including a steep longitudinal slope and abundant loose material sources. They often experience debris flow with a strong impact force and a large instantaneous flow. Drainage ... ver más
Revista: Water

 
Oleksii Klymenko     Pág. 43 - 52
This study analyzes the change in the calculated reduced emissions of pollutants by all major categories of road vehicles of European environmental classes from "Euro-0" to "Euro-6". It covers cars, light commercial vehicles, trucks, buses, and category ... ver más

 
Lixia Ying, Zhen Fu, Ke Wu, Chunxi Wu, Tengfei Zhu, Yue Xie and Guixiang Wang    
The aim of this paper is to obtain Cu–Sn composite coatings incorporated with PTFE and TiO2 particles, which have superior antiwear and friction reduction properties. Electrodeposition was carried out in a pyrophosphate electrolyte, and the electro... ver más
Revista: Coatings