Inicio  /  Water  /  Vol: 14 Par: 18 (2022)  /  Artículo
ARTÍCULO
TITULO

Modification of Disinfection Process at a Local Water Treatment Plant?Skawina (Poland)

Bogumila Winid    
Robert Muszanski and Jan Wilkosz    

Resumen

This paper summarizes studies undertaken at a water treatment plant in Skawina (WTP Skawina) where the disinfection process was modified by introducing a mobile ozonation system. The application of a small-size, fully-automated ozonation installation only slightly complicates the water treatment process, without the need to redesign the water treatment line, and with relatively low investment costs. The aim of this study was to analyze whether the change of the disinfection method affects the final water quality. The investigated water samples were treated in the mobile ozonation system using a disinfection process with only sodium hypochlorite. Treated water was of excellent quality, and seasonal variations in raw water parameters (variable organic matter contents) did not result in elevated trihalomethanes (THM) and bromate concentrations. Despite the trace amounts of bromides in the water prior to treatment, the water in the municipal drinking water system did not contain determinable amounts of bromates. The bromine concentrations in the treated water supplied to the water distribution system were higher than in raw water, which could be attributable to the presence of bromine as a contaminant in sodium hypochlorite (the disinfection agent). Water quality tests carried out by the water treatment plant (WTP) and by the State Sanitary Inspectorate after the modification of the process line confirmed the high quality of water in the distribution network after the change of disinfection method.

 Artículos similares

       
 
Alice Zaghini, Francesca Gagliardi, Valentina Marsili, Filippo Mazzoni, Lorenzo Tirello, Stefano Alvisi and Marco Franchini    
Providing water with adequate quality to users is one of the main concerns for water utilities. In most countries, this is ensured through the introduction of disinfectants, such as chlorine, which are subjected to decay over time, with consequent loss o... ver más
Revista: Water

 
Li Li, Gyumin Lee and Doosun Kang    
A model that computes the per-unit process energy consumption, energy intensity, CO2 emission, and CO2 intensity of water treatment plants is developed. This model is used to estimate the total energy consumption of six water treatment plants in Seoul Me... ver más
Revista: Water

 
Andjelka Simic, Mirjana V. Papic, Ana Nikitovic, Aleksandar Kocovic, Renata Petrovic, Irena Melih, Suzana Zivanovic, Milos Papic and Milica Popovic    
This study investigates the pH values and optical characteristics of Dual Rinse HEDP, either independently or combined with sodium hypochlorite (NaOCl), and compares them to other irrigants used in endodontics. The solutions used in this study were comme... ver más
Revista: Applied Sciences

 
Sajeeve Latif, Mohammad A. Alim, Ataur Rahman and Md Mahmudul Haque    
The supply of safe drinking water to rural communities has always been challenging, unlike in most large cities where government authorities have constructed central water supply systems. In many rural areas, primary water sources such as surface water a... ver más
Revista: Water

 
Sanam Bhatti, Tanveer A. Gadhi, Rasool Bux Mahar, Imran Ali, Najeebullah Channa, Junaid Ahmed Kori and Barbara Bonelli    
Biofilms in water distribution lines strongly affect water safety as they are the main carriers of pathogens. The current study investigated the biofilm formation and identification of selected pathogens in different distribution pipeline materials and t... ver más
Revista: Water