Inicio  /  Water  /  Vol: 15 Par: 5 (2023)  /  Artículo
ARTÍCULO
TITULO

Numerical Simulation Study on the Influence of Construction Load on the Cutoff Wall in Reservoir Engineering

Yongshuai Sun    
Anping Lei    
Ke Yang and Guihe Wang    

Resumen

Relying on the Beijing-Shijiazhuang Expressway widening project near the impervious wall of a reservoir, this paper uses FLAC3D two-dimensional and three-dimensional numerical simulation methods to establish the whole process model of the impervious wall of the reservoir affected by the construction load of the high-way reconstruction section. The stress and strain state of the cut-off wall in the high-way reconstruction section and the nearby reservoir is simulated in detail, the overall deformation of the cut-off wall in the reservoir is directly reflected, and the interaction and differential deformation between the wall structures are reflected. The safety and stability of the cutoff wall of the reservoir affected by the construction load are evaluated so that various advanced mechanical behaviors of the cutoff wall can be predicted. Research results show that the horizontal displacement value of the wall gradually increases from bottom to top, and the maximum value appears at the top of the wall. The horizontal displacement value of the 1?3 walls is relatively large, with the maximum value of 22.368 mm, and the horizontal displacement value of the 4?10 walls shows little difference. This is on account of the gravity of the backfill, the strata in the whole project area having settled, and the settlement at the bottom of the cut-off wall being 2.542 mm. At the root of the rigid cut-off wall, the compressive stress concentration occurs, with the maximum value between 1.75 MPa and 2.15 MPa. Due to the size of the structure, the maximum tensile stress of 0.237 MPa appears in the local area near the guide wall of the rigid cut-off wall, which will not endanger the rigid cut-off wall because of its small value. The maximum stress in the rigid impervious wall and the plastic impervious wall are 1.90?2.15 MPa and 1.00?1.12 MPa, respectively. Apart from the small tensile stress at the connecting guide wall between the rigid cut-off wall and the plastic concrete cut-off wall, the cut-off wall is under pressure, especially the plastic cut-off wall. Combined with the analysis of the stress state of the wall, it can be determined that the anti-seepage wall (rigid cut-off wall and plastic concrete cut-off wall) is stable and safe during the construction period.

 Artículos similares

       
 
Tao Sun, Fakai Yang, Xinzhuang Cui, Zhaochao Huang, Xianzhou Lyu, Ruijin Ma, Yujun Chang, Shengmei Liu, Chen Wang, Zhiyuan Lin and Xiaoning Zhang    
To solve the problem of the high bearing capacity of structures in deep and weak soil layers, we invented a new type of pile group foundation in which the soil was continuously solidified between piles (hereinafter referred to as the SCS pile group found... ver más
Revista: Buildings

 
Zhe Wang, Weisheng Xu, Qing Xu, Yangming Wang and Yingna Zhu    
To investigate the mechanism of reinforcing soft soil with cement-mixing pile, based on ABAQUS secondary development, a numerical simulation study of the hydration reaction of cement-mixing piles was conducted. In this study, the influence of ground temp... ver más
Revista: Buildings

 
Ping Chen, Lufeng Nie, Jinrun Kang and Heng Liu    
With urban development and renewal, underground space is becoming more utilized. The design and use of open underground public space entrances and exits have become more and more frequent. As a pedestrian passage connecting indoors and outdoors, the wind... ver más
Revista: Buildings

 
Yonghai He, Songtao Lv, Nasi Xie, Huilin Meng, Wei Lei, Changyu Pu, Huabao Ma, Ziyang Wang, Guozhi Zheng and Xinghai Peng    
This study addressed the complex problems of selecting a constitutive model to objectively characterize asphalt mixtures and accurately determine their viscoelastic properties, which are influenced by numerous variables. Inaccuracies in model or paramete... ver más
Revista: Buildings

 
Yu Zheng, Chunfang Lu, Xiaomin Huang, Weibing Xu, Daxing Zhou, Jin Li, Jianxiang Li, Liqun Hou, Kuan Wang and Yulong Sun    
To study how varying the parameters of expansion joints and bearing supports (E-B parameters) affects the dynamic response of a coupled vehicle?bridge system for curved girder bridges, a dynamic response analysis method for the coupled vehicle?joint (bea... ver más
Revista: Buildings