ARTÍCULO
TITULO

Performance Evaluation of Control Compatibility for an OTEC Pump Shutdown Condition

Seungtaek Lim    
Jiwon Yoon    
Hosaeng Lee and Hyeonju Kim    

Resumen

South Korea is currently in the preparatory stage of commercializing an ocean thermal energy conversion (OTEC) system, as the demonstration of a 1 MW scale OTEC system has been accomplished. However, the commercialization of OTEC requires the establishment of a control system for various environmental changes. Therefore, pre-emptive identification of the system?s risk factors and the process of analyzing the impact of the system, building control items, and optimizing control are necessary. This study aims to establish and analyze an optimized control system for MW-scale OTEC risk factors, such as the shutdown of seawater or refrigerant pumps. The selected OTEC system was designed for 1070 kW class facilities, with a 36.6% portion of total electricity usage by the seawater pump and refrigerant pump. As a result, an on/off control system was adopted in order to eliminate the risk factors. By adjusting this option, dry operation of the refrigerant pump, water hammering, and liquid inflow into the turbine were successfully prevented. To be more specific, the initial system was to be shut down due to a sharp decrease in power at the point where the deep seawater flow rate was 538 kg/s (35.7% of max flow rate) and the surface seawater flow rate was 715 kg/s (38.4% of max flow rate). This situation was improved by adopting parallel operation of seawater pumps and on/off control, thereby leading to a more stabilized operation by maintaining a flow rate of over 1864 kg/s for surface seawater and 1507 kg/s for deep seawater. Moreover, it was confirmed that the flow rate of the pump was reduced by 1.89 kg/s per second in the process of pump shutdown during a single operation mode of the refrigerant pump. Parallel operation made it possible to maintain 60.2% of the output by increasing the power of the second pump?s flow rate in the event of the first pump shutting down. The final seawater temperature differential power generation model derived from this study consists of two refrigerant pumps and two surface seawater and deep seawater pumps in order to prevent system shutdown caused by a single pump failure. The final design was reflected in the final delivery to Kiribati, which is located near the equator.

 Artículos similares

       
 
Gonçalo J. M. Rosa, João M. S. Afonso, Pedro D. Gaspar, Vasco N. G. J. Soares and João M. L. P. Caldeira    
Pedestrian crossings are an essential part of the urban landscape, providing safe passage for pedestrians to cross busy streets. While some are regulated by timed signals and are marked with signs and lights, others are simply marked on the road and do n... ver más
Revista: Information

 
Wonjae Yoon, Vikas Khandu Bhosale and Hosung Yoon    
The development of propulsion systems based on green propellants, as an alternative to hydrazines, has been gaining interest within the space community. The study of Ammonium Dinitramide (ADN)-based liquid monopropellant, which is low-toxic and can deliv... ver más
Revista: Aerospace

 
Long Bin Tan and Linus Yinn Leng Ang    
This study aims to tackle the challenge of high noise levels on balconies while preserving natural ventilation. Eight innovative balcony designs, incorporating elements like diffuser edges, undulating ceilings, Helmholtz resonators, grooves, or sound tra... ver más
Revista: Acoustics

 
Liming Li and Zeang Zhao    
To effectively enhance the adaptability of earthquake rescue robots in dynamic environments and complex tasks, there is an urgent need for an evaluation method that quantifies their performance and facilitates the selection of rescue robots with optimal ... ver más
Revista: Applied Sciences

 
Brian G. Roche, Michael A. Perez, Wesley N. Donald and Jarrell Blake Whitman    
Sediment barriers are used on construction sites to protect downstream waterbodies from the impacts of sediment-laden stormwater runoff. Although ubiquitous on construction sites, many sediment barrier practices lack performance-based testing to determin... ver más
Revista: Water