Inicio  /  Instruments  /  Vol: 4 Par: 2 (2020)  /  Artículo
ARTÍCULO
TITULO

TomoPress?In Situ Synchrotron-Based Microtomography under Axial Load

Alexander Rack    
Johannes Stroebel    
Tatjana Rack    
Yves Dabin    
Christine Knabe    
Michael Stiller    
Paola Coan and Pierre Bleuet    

Resumen

Computed tomography (CT) with hard X-rays is a mature technique that is in regular use to depict the interior of opaque specimens with spatial resolutions up to the micrometre range (microtomography or µCT). Short acquisition times and sophisticated contrast modes are accessible when synchrotron light sources are combined with microtomography?SR-µCT. Both features render SR-µCT as excellent probe to study delicate samples in situ, for example under mechanical load by deploying corresponding sample environments. The so-called TomoPress is such a device available within the public user programme of tomography beamline ID19 of the European Synchrotron Radiation Facility (ESRF). It allows one to study samples under high axial load (up to 500 N) with high spatial resolution up to the micrometer range. Different gauges are installed to allow online monitoring of the applied force. Constant humidity, temperature and wetting are routinely available as well. The article shall outline basic design principles of the press as well as parameters for its utilisation in a descriptive manner. Selected examples underline the potential of the device for such diverse fields as biomedical research, life sciences and materials research.

 Artículos similares

       
 
Choirul Anam, Ariij Naufal, Heri Sutanto, Kusworo Adi and Geoff Dougherty    
A bilateral filter is a non-linear denoising algorithm that can reduce noise while preserving the edges. This study explores the characteristics of a bilateral filter in changing the noise and texture within computed tomography (CT) images in an iterativ... ver más
Revista: Algorithms

 
Jinhuan Zhao, Changling Liu, Chengfeng Li, Yongchao Zhang, Qingtao Bu, Nengyou Wu, Yang Liu and Qiang Chen    
Characterizing the electrical property of hydrate-bearing sediments is essential for hydrate reservoir identification and saturation evaluation. As the major contributor to electrical conductivity, pore water is a key factor in characterizing the electri... ver más

 
Johannes Leidner, Fabrizio Murtas and Marco Silari    
The GEMPix is a small gaseous detector with a highly pixelated readout, consisting of a drift region, three Gas Electron Multipliers (GEMs) for signal amplification, and four Timepix ASICs with 55 µm pixel pitch and a total of 262,144 pixels. A continuou... ver más
Revista: Applied Sciences

 
Yin Chun Hung, Ho Shu Chou and Chih Ping Lin    
In the past decade, the 2D electrical resistivity tomography (ERT) has been extensively used in the investigation and monitoring of geotechnical engineering and environment engineering, but there are many uncertainties hidden behind its vivid color earth... ver más
Revista: Applied Sciences

 
Jan Sher Akmal, Mika Salmi, Björn Hemming, Linus Teir, Anni Suomalainen, Mika Kortesniemi, Jouni Partanen and Antti Lassila    
Accuracy of additively manufactured implants for clinical surgery.
Revista: Applied Sciences