Mitigation of Asymmetrical Grid Faults in Induction Generator-Based Wind Turbines Using Constant Power Load

Nadeem Jelani and Marta Molinas    

Resumen

Constant power loads (CPLs), interfaced through active rectifiers can be used for improving the stability of induction generator (IG)-based wind turbines under balanced grid voltage dips by providing the reactive power. Under asymmetrical grid faults, the negative sequence voltage produces additional generator torque oscillations and reduces the lifetime of the installed equipment. This article explores the possibility of using a CPL for mitigation of unbalanced voltage dips in an AC distribution system in addition to consuming a constant active power. Unbalanced fault mitigation as an ancillary service by the load itself could greatly increase the stability and performance of the overall power system. A CPL control structure, capable of controlling the positive and negative sequence of the grid voltage is suggested. The simulation results clearly indicate the effects of compensating the positive and negative sequence of the grid voltage on the performance of IG based wind turbines. The maximum Fault Ride Through (FRT) enhancement has been given priority and is done by the compensation of positive sequence voltage. The remaining CPL current capacity is used to compensate the negative sequence voltage in order to reduce the additional torque ripples in the IG.

 Artículos similares

       
 
Vicente León-Martínez and Joaquín Montañana-Romeu    
Operation of doubly fed induction generators subjected to transient unbalanced voltage dips is analyzed in this article to verify the fulfillment of the Spanish grid code. Akagi?s p-q theory is not used for this study, because control of the electronic c... ver más
Revista: Energies

 
Lin Chen, Qing Yang, Jing Wang, Wenxia Sima and Tao Yuan    
This paper proposes a simple and effective method for classification of fundamental ferroresonance, single phase-to-ground and wire breakage over-voltages. In isolated neutral networks, power frequency over-voltages due to ferroresonance, single phase-to... ver más
Revista: Energies

 
Jingyu Yan, Guoqing Xu, Huihuan Qian, Yangsheng Xu and Zhibin Song    
Battery fast charging is one of the most significant and difficult techniques affecting the commercialization of electric vehicles (EVs). In this paper, we propose a fast charge framework based on model predictive control, with the aim of simultaneously ... ver más
Revista: Energies

 
V. H. Sychenko,D. O. Bosyj     Pág. 82 - 87