Inicio  /  Energies  /  Vol: 9 Núm: 7 Par: July (2016)  /  Artículo
ARTÍCULO
TITULO

Thermal Hydraulic Performance in a Solar Air Heater Channel with Multi V-Type Perforated Baffles

Anil Kumar and Man-Hoe Kim    

Resumen

This article presents heat transfer and fluid flow characteristics in a solar air heater (SAH) channel with multi V-type perforated baffles. The flow passage has an aspect ratio of 10. The relative baffle height, relative pitch, relative baffle hole position, flow attack angle, and baffle open area ratio are 0.6, 8.0, 0.42, 60°, and 12%, respectively. The Reynolds numbers considered in the study was in the range of 3000?10,000. The re-normalization group (RNG) k-e turbulence model has been used for numerical analysis, and the optimum relative baffle width has been investigated considering relative baffle widths of 1.0?7.0.The numerical results are in good agreement with the experimental data for the range considered in the study. Multi V-type perforated baffles are shown to have better thermal performance as compared to other baffle shapes in a rectangular passage. The overall thermal hydraulic performance shows the maximum value at the relative baffle width of 5.0.

 Artículos similares

       
 
Enhanced heat transfer surfaces allow more energy-efficient, compact and lightweight heat exchangers. Within this study, a method for comparing different types of enhancement and different geometries with multiple objectives is developed in order to eval... ver más
Revista: Energies

 
Zhongchao Zhao, Yimeng Zhou, Xiaolong Ma, Xudong Chen, Shilin Li and Shan Yang    
Revista: Energies

 
Haonan Tian, Zhongbao Wei, Sriram Vaisambhayana, Madasamy Thevar, Anshuman Tripathi and Philip Kjær    
Medium-frequency (MF) transformer has gained much popularity in power conversion systems. Temperature control is a paramount concern, as the unexpected high temperature declines the safety and life expectancy of transformer. The scrutiny of losses and th... ver más
Revista: Energies

 
The thermal energy storage (TES) system stores the district heating (DH) water when the heating load is low. Since a TES system stores heat at atmospheric pressure, the DH water temperature of 115 °C has to be lowered to less than 100 °C. Therefo... ver más
Revista: Energies

 
End fittings are essential components in marine flexible pipe systems, performing the two main functions of connecting and sealing. To investigate the sealing principle and the influence of the temperature on the sealing performance, a hydraulic-thermal ... ver más
Revista: Energies