ARTÍCULO
TITULO

Seismic performance of frames with passive energy dissipation steel slit plates

Juan Pimiento    
Andrés Salas    
Daniel Ruiz    

Resumen

This paper evaluates two types of hysteretic passive energy dissipation devices (steel slit plates). These devices are low-cost and easy to build and install. The seismic performance of three structural models were studied with shake table tests: a frame without energy dissipation device and two frames with two types of steel slit plates. The models were instrumented with accelerometers, strain gages and LVDTs, and were subjected to two types of earthquakes signals: a regional earthquake and a near-field ground motion. The results of laboratory tests suggest that the frame with steel slit plates have up to 90% less seismic drift than the frame without rehabilitation. This is because steel slit plates dissipated a large portion of the input energy supplied by earthquakes and the damage to the parent structure was minimized.Rev. ing. constr. [online]. 2014, vol.29, n.3, pp. 283-298. ISSN 0718-5073.  http://dx.doi.org/10.4067/S0718-50732014000300005

 Artículos similares

       
 
Runqi Guo, Haiying Zhang, Kezheng Chen, Yang Song, Hongxia Li, Lin Ding and Yanjie Liu    
In order to improve the seismic performance of reinforced concrete (RC) columns, a reinforcement technology using prestressed steel wire ropes embedded in polyurethane cement composite material is proposed. Four concrete columns reinforced with different... ver más
Revista: Buildings

 
Jian Yang, Ming Sun, Guohuang Yao, Haizhu Guo and Rumian Zhong    
This study explores an advanced prefabricated composite structure, namely ECC/RC composite shear walls with enhanced seismic performance. This performance enhancement is attributed to the strategic use of engineered cementitious composites (ECC) known fo... ver más
Revista: Buildings

 
Dimitrios Noitsis, Georgia A. Beletsioti, Anastasios Valkanis, Konstantinos Kantelis, Georgios Papadimitriou and Petros Nicopolitidis    
Traffic on backbone communication networks is growing significantly every year. This results in an increase in both energy consumption and the carbon footprint they leave on the environment. As a response, research efforts are focused on reducing energy ... ver más
Revista: Applied Sciences

 
Niki Balkamou and George Papagiannopoulos    
Steel Plate Shear Walls (SPSW) provide significant lateral load capacity and can be utilized in the seismic retrofit and upgrade of existing reinforced concrete (r/c) buildings. In this study, the application of SPSW to retrofit a r/c building designed a... ver más
Revista: Applied Sciences

 
Sajjad E. Rasheed, Duaa Al-Jeznawi, Musab Aied Qissab Al-Janabi and Luís Filipe Almeida Bernardo    
The structural stability of pipe pile foundations under seismic loading stands as a critical concern, demanding an accurate assessment of the maximum settlement. Traditionally, this task has been addressed through complex numerical modeling, accounting f... ver más