Inicio  /  Water Research  /  Vol: 117 Par: 0 (2017)  /  Artículo
ARTÍCULO
TITULO

Microbial fuel cells for inexpensive continuous in-situ monitoring of groundwater quality

S.B. Velasquez-Orta    
D. Werner    
J.C. Varia    
S. Mgana    

Resumen

Online monitoring of groundwater quality in shallow wells to detect faecal or organic pollution could dramatically improve understanding of health risks in unplanned peri-urban settlements. Microbial fuel cells (MFC) are devices able to generate electricity from the organic matter content in faecal pollution making them suitable as biosensors. In this work, we evaluate the suitability of four microbial fuel cell systems placed in different regions of a groundwater well for the low-cost monitoring of a faecal pollution event. Concepts created include the use of a sediment/bulk liquid MFC (SED/BL), a sediment/sediment MFC (SED/SED), a bulk liquid/air MFC (BL/Air), and a bulk liquid/bulk liquid MFC (BL/BL). MFC electrodes assembly aimed to use inexpensive, durable, materials, which would produce a signal after a contamination event without external energy or chemical inputs. All MFC configurations were responsive to a contamination event, however SED/SED and BL/Air MFC concepts failed to deliver a reproducible output within the tested period of time. BL/BL MFC and SED/BL MFCs presented an increase in the average current after contamination from -0.75 ± 0.35 µA to -0.66 ± 0.41 µA, and 0.07 ± 0.2 mA to 0.11 ± 0.03 mA, respectively. Currents produced by the SED/BL MFC (SMFC) were considerably higher than for the BL/BL MFCs, making them more responsive, readable and graphically visible. A factorial design of experiments (DOE) was applied to evaluate which environmental and design factors had the greatest effect on current response in a contamination event. Within the ranges of variables tested, salinity, temperature and external resistance, only temperature presented a statistically significant effect (p = 0.045). This showed that the biosensor response would be sensitive to fluctuations in temperature but not to changes in salinity, or external resistances produced from placing electrodes at different distances within a groundwater well.

 Artículos similares

       
 
Yu Kong, Jing Hu, Xiwu Lu and Changgen Cheng    
The tail wastewater from sewage treatment facilities usually lacks carbon sources, and its subsequent treatment for deep nitrogen removal is difficult in natural conditions. In this study, the constructed wetland (CW) was integrated with microbial fuel c... ver más
Revista: Water

 
Haikun Zhang, Manman Cheng, Yan Li and Wenhao Chen    
In recent years, quinoid redox mediators (QRMs) have attracted increasing attention because of their key role in wastewater biotreatment. Previous studies have shown that the anaerobic respiration of many bacteria could be coupled to the reduction and re... ver más
Revista: Water

 
Ge Qin, Hongyu Feng, Rendong Yu, Fuchao Zheng, Xufei Jiang, Lu Xia and Shuqing An    
Pharmaceuticals and Personal Care Products (PPCPs) constitute a group of compounds that are challenging to break down and potentially pose risks to both ecosystems and human health when they accumulate in water bodies. This study established and operated... ver más
Revista: Water

 
Yucui Shi, Gang Tang, Shaohong You and Pingping Jiang    
Revista: Applied Sciences

 
Yuyang Wang, Guangxu Hu, Dayu Zheng, Jing Dong and Jing Wang    
Microbial fuel cell (MFC) technology can potentially recover bioelectricity from wastewater. However, its practical applications have been limited because of its low power density and since the energy generated from an MFC cannot be stored. In this study... ver más
Revista: Coatings