Inicio  /  Energies  /  Vol: 9 Núm: 3 Par: March (2016)  /  Artículo
ARTÍCULO
TITULO

An Actuator Control Unit for Safety-Critical Mechatronic Applications with Embedded Energy Storage Backup

Sergio Saponara    

Resumen

This paper presents an actuator control unit (ACU) with a 450-J embedded energy storage backup to face safety critical mechatronic applications. The idea is to ensure full operation of electric actuators, even in the case of battery failure, by using supercapacitors as a local energy tank. Thanks to integrated switching converter circuitry, the supercapacitors provide the required voltage and current levels for the required time to guarantee actuator operation until the system enters into safety mode. Experimental results are presented for a target application related to the control of servomotors for a robotized prosthetic arm. Mechatronic devices for rehabilitation or assisted living of injured and/or elderly people are available today. In most cases, they are battery powered with lithium-based cells, providing high energy density and low weight, but at the expense of a reduced robustness compared to lead-acid- or nickel-based battery cells. The ACU of this work ensures full operation of the wearable robotized arm, controlled through acceleration and electromyography (EMG) sensor signals, even in the case of battery failure, thanks to the embedded energy backup unit. To prove the configurability and scalability of the proposed solution, experimental results related to the electric actuation of the car door latch and of a robotized gearbox in vehicles are also shown. The reliability of the energy backup device has been assessed in a wide temperature range, from -40 to 130 °C, and in a durability test campaign of more than 10,000 cycles. Achieved results prove the suitability of the proposed approach for ACUs requiring a burst of power of hundreds of watts for only a few seconds in safety-critical applications. Alternatively, the aging and temperature characterizations of energy backup units is limited to supercapacitors of thousands of farads for high power applications (e.g., electric/hybrid propulsion) and with a temperature range limited to 70 °C.

 Artículos similares

       
 
Kyoung Jin Joo, Gang Seok Lee, Hyun Seok Hong, Sung Hong Won and Ju Lee    
Since an existing 3-phase inner rotor torque actuator (TA) has severe torque ripples, it is not appropriate for a gimbal system that requires precise position control. Therefore, a coreless TA is considered to eliminate the core causing torque ripples. I... ver más
Revista: Energies

 
Mohamed Hechmi El Ouni, Mohamed Y. Laissy, Mohammed Ismaeil and Nabil Ben Kahla    
The study aims to assess the impact of shear walls on active vibration control of the buildings. It has evaluated the design of a smart 20-story building equipped with an Active Mass Damper to mitigate earthquakes. The design has combined shear walls wit... ver más

 
Valeria Castellucci, Johan Abrahamsson, Tobias Kamf and Rafael Waters    
The power production of the linear generator wave energy converter developed at Uppsala University is affected by variations of mean sea level. The reason is that these variations change the distance between the point absorber located on the surface and ... ver más
Revista: Energies

 
Seyed Mojtaba Tabatabaeipour, Peter F. Odgaard, Thomas Bak and Jakob Stoustrup    
In this paper a set-membership approach for fault detection of a benchmark wind turbine is proposed. The benchmark represents relevant fault scenarios in the control system, including sensor, actuator and system faults. In addition we also consider param... ver más
Revista: Energies

 
V. V. Malovichko,V. I. Gavryliuk     Pág. 5 - 8