12   Artículos

 
en línea
Letizia Castelli, Chiara Iacovelli, Siria Ciccone, Valerio Geracitano, Claudia Loreti, Augusto Fusco, Lorenzo Biscotti, Luca Padua and Silvia Giovannini    
Osteoarthritis is a common chronic condition in the elderly population and, with falls, represents a major public health problem. Patients with hip or knee osteoarthritis often have poor balance, which is considered an important risk factor for falls. In... ver más
Revista: Applied Sciences    Formato: Electrónico

 
en línea
Stefano Marco Paolo Rossi, Fabio Mancino, Rudy Sangaletti, Loris Perticarini, Ludovico Lucenti and Francesco Benazzo    
The development of augmented reality (AR) and its application in total joint arthroplasty aims at improving the accuracy and precision in implant components? positioning, hopefully leading to increased outcomes and survivorship. However, this field is fa... ver más
Revista: Applied Sciences    Formato: Electrónico

 
en línea
Maeruan Kebbach, Christian Schulze, Christian Meyenburg, Daniel Kluess, Mevluet Sungu, Albrecht Hartmann, Klaus-Peter Günther and Rainer Bader    
The calculation of range of motion (ROM) is a key factor during preoperative planning of total hip replacements (THR), to reduce the risk of impingement and dislocation of the artificial hip joint. To support the preoperative assessment of THR, a magneti... ver más
Revista: Applied Sciences    Formato: Electrónico

 
en línea
Vicente Cortes, Carlos A. Rodriguez Betancourth, Javier A. Ortega and Hasina Huq    
One of the main causes of hip prostheses failure is the premature wear of their components. Multi-directional motion or ?cross-shear? motion has been identified as one of the most significant factors affecting the wear rate of UHMWPE in total hip joint r... ver más
Revista: Instruments    Formato: Electrónico

 
en línea
Toufik Bousnane, Smail Benbarek, Abderahmen Sahli, Boualem Serier, Bel Abbes Bachir Bouiadjra     Pág. 173 - 178
In orthopedic surgery and particularly in total hip arthroplasty, fixation of femoral implant is generally made by the surgical cement. Bone?cement interface has long been implicated in failure of cemented total hip replacement (THA), it is actually a cr... ver más
Revista: Periodica Polytechnica: Mechanical Engineering    Formato: Electrónico

 
en línea
Georgios I. Tagarakis, Costas Dikeos, Nikolaos Tsilimingas, Charalampos Tsairidis, Fani Tsolaki, Marios Daskalopoulos, Nikolaos Polyzos     Pág. 2986 - 2987
Aim. To evaluate the Greek Diagnosis Related Groups(DRG's)system in regard to the procedure of total hip arthroplasty.Methods. In a tertiary university orthopedics department implementing clinical protocols we recruited 75 consecutive patients planned to... ver más

 
en línea
Mohammed Elnedhir Belgherras, Boualem Serier, Ali Benouis, Lalia Hachemi     Pág. 204 - 212
In orthopedic surgery and particularly in total hip arthroplasty, The fixation of the implant is generally made by the surgical cement, constituted essentially by polymer (PMMA), It is necessary to know the strengths applied to the prosthetic articulatio... ver más
Revista: Periodica Polytechnica: Mechanical Engineering    Formato: Electrónico