Benjamin J. Brimacombe, James A. Scobie, Joseph M. Flynn, Carl M. Sangan and Oliver J. Pountney
This paper presents experimental measurements of adiabatic effectiveness for three transpiration cooling porosities (ϕ=" role="presentation">??=?=
?
=
0.3, 0.4, and 0.5) constructed from gyroid lattice structures. To the authors? knowledge, th...
ver más
|
|
|
|
|
|
|
Hui Tang, GeonHwan Cho, Mario Patinios, James A. Scobie, Carl M. Sangan, J. Michael Owen and Gary D. Lock
Ingress is the penetration of a hot mainstream gas in a turbine annulus through the rim seal into the wheel-space between the rotating turbine disc (the rotor) and the adjacent stationary casing (the stator). Purge flow is used to prevent or reduce ingre...
ver más
|
|
|
|
|
|
|
Marios Patinios, James A. Scobie, Carl M. Sangan and Gary D. Lock
This paper presents measurements of CO2 concentration and pressure in a new, highly instrumented and versatile, 1.5-stage gas turbine facility. The rig, which has been specifically designed for investigations related to hot gas ingestion, features interc...