Thomas Wüest, Philipp Schuetz and Andreas Luible    
The experimental setup implements a simplified PASSYS test cell construction, which is combined with a detailed simulation to reduce measurement effort. To analyze the cell?s dynamic behavior, the test cell was closely monitored with thermal sensors, and... ver más
Revista: Buildings    Formato: Electrónico

 
en línea
Samuel Stamp, Hector Altamirano-Medina and Robert Lowe    
Revista: Buildings    Formato: Electrónico

 
en línea
Ludovico Danza, Benedetta Barozzi, Lorenzo Belussi, Italo Meroni and Francesco Salamone    
The aim of the article is to describe the results of an experimental campaign based on the assessment of a heat recovery unit coupled with a dynamic window. Two fully monitored and calibrated outdoor test cells are used, in order to evaluate the energy p... ver más