Inicio  /  Buildings  /  Vol: 13 Par: 11 (2023)  /  Artículo
ARTÍCULO
TITULO

Direct Tensile Capacity of Steel-Tube Connections in a Precast Concrete Double-Wall System

Didar Meiramov    
Yujae Seo    
Hyunjin Ju and Hae-Chang Cho    

Resumen

This study introduces a new precast concrete (PC) double-wall system designed to simplify the complex fabrication process of existing PC double-wall systems and eliminate laitance and other defects that can occur during the manufacture of concrete panels. An experiment and finite element analysis were conducted on 11 specimens to determine the tensile resistance performance of rectangular steel tubes that maintain spacing to avoid damage to the PC panels during transportation or on-site installation. Specimens varied in terms of the end details of the rectangular steel tubes, such as the presence of welded steel plates or embedded concrete and total length in terms of whether longer or shorter specimens were used. As a result, the specimens showed a 20?30% increase in maximum tensile strength compared to the control specimen according to the end details, except for the case where side steel plates were cut and bent inward. The control specimen filled with concrete was the most suitable for connections when constructing PC double-wall systems. It has significant tensile resistance according to the experiment and finite element analysis and does not require additional construction steps or costs.

 Artículos similares

       
 
Fakhri Mansour, Vanaei Vahid     Pág. 506 - 512
It may be stated that the main reason for the failure of asphalt pavement, especially early damage, is due to destruction and loss of adhesion properties of bitumen in the asphalt mix. Stripping is the weakening or the loss of adhesion between the aggreg... ver más

 
Tereza Valentová, Jan Altman, Jan Valentin     Pág. 768 - 777
Bitumen-aggregate adhesion is one of the crucial characteristics related to an asphalt mix. It affects the mix durability mainly in terms of its moisture susceptibility. Wide range of adhesion promoters is available to the market and can be used in regul... ver más

 
I.N. Paes, E. Bauer, H. Carasek, E. Pavón     Pág. Page 175 - 186
In the present study was performed an evaluation of the water transport in the mortar/block system, with the objective of linking the behavior of the bond strength by perpendicular tensile stress, and with water movement and porosity of mortar. This was ... ver más

 
Sergio Carmona Malatesta, Antonio Aguado de Cea, Climent Molins Borrell, Manuel Cabrera Contreras     Pág. Page 119 - 140
Traditionally, flexural testing of prismatic beams is used to characterize the strength and behavior in post - cracking regime of fiber - reinforced concretes (FRC). These tests exhibit a high dispersion in their results, and therefore invalidate the use... ver más