Inicio  /  Applied Sciences  /  Vol: 14 Par: 1 (2024)  /  Artículo
ARTÍCULO
TITULO

Compact SOI Dual-Mode (De)multiplexer Based on the Level Set Method

Han Zheng    
Shanglin Yang    
Yue Yu and Lei Zhang    

Resumen

Mode (de)multiplexer is an essential device in integrated multimode photonic systems. Here, we present a dual-mode (de)multiplexer that separates two input modes, TE0 and TE1, into two output ports while converting TE1 to TE0 mode. Based on the adjoint and level set method, the device features a small footprint of 9.4 µm × 2.9 µm, and a minimum feature size over 200 nm is achieved, affirming stable and reliable fabrication. Through simulations, we observed insertion losses of less than 0.28 dB for TE0 mode and 0.35 dB for TE1 mode within the wavelength range of 1500?1600 nm, accompanied by crosstalk levels lower than -30 dB. In our experimental tests, we achieved insertion losses of less than 0.89 dB for TE0 mode and 0.44 dB for TE1 modes within the 1530 nm to 1570 nm range, with crosstalk maintained below -25 dB. Furthermore, we conducted an experimental verification of the differences between the standard device and the boundary dilation/erosion device, observing an insertion loss degradation by 0.61 dB within a deviation range of ±40 nm, which demonstrates the device?s robustness to the fabrication. The proposed devices exhibit exceptional performance and feature a compact structure, thus holding significant potential for the development of future multimode integrated photonic circuits.

 Artículos similares

       
 
Alessandro Antonelli, Francesco Bennardo, Ylenia Brancaccio, Selene Barone, Felice Femiano, Ludovica Nucci, Giuseppe Minervini, Leonzio Fortunato, Ferdinando Attanasio and Amerigo Giudice    
Background: This study aims to analyze bone compaction and osseodensification techniques and to investigate how cancellous bone compaction could influence primary implant stability (PS). Methods: Two different surgical protocols (bone compactors?BC; osse... ver más
Revista: Applied Sciences

 
Yehree Kim, Jeon Min Kang, Ho-Young Song, Woo Seok Kang, Jung-Hoon Park and Jong Woo Chung    
This study was conducted to investigate the efficacy of a self-expandable retainer (SER) for endoscopic visualization of the external auditory canal (EAC). Tympanomeatal flap (TMF) elevation was performed in six cadaveric heads. Two different types of SE... ver más
Revista: Applied Sciences

 
Linh Duc Tam Ho DOI: 10.26459/hueuni-jtt.v128i2B.5332    
We propose a new design of a 2x2 optical chip for switching optical modes based on silicon material. Input lights at fundamental mode of transverse electric (TE) polarization can be selected at the output by appropriately controlling a 180-degree butterf... ver más

 
Youssef El Halal, Crístofer H. Marques, Luiz A. O. Rocha, Liércio A. Isoldi, Rafael de L. Lemos, Cristiano Fragassa and Elizaldo D. dos Santos    
In the present work it is performed a numerical study for simulation of turbulent air and water flows in a nozzle based on the Coanda effect named H.O.M.E.R. (High-Speed Orienting Momentum with Enhanced Reversibility). The main purposes of this work are ... ver más

 
A. B. M. Saiful Islam     Pág. 354 - 363
Significantly growing construction in the earthquake vulnerable regions needs appropriate handling of seismic prone buildings. Insertion of high damping rubber bearing (HDRB) at the building base might be an attractive option for structural safety and ec... ver más