In situ measurement can enable accurate evaluation of a building?s as-built performance. However, when measuring whole house performance, party walls introduce measurement uncertainty. Subsequently, it is common to ?adjust? measurements to isolate heat transfer through party walls. This study explores the behaviour and impact of party walls in QUB and coheating measurements of a semi-detached house, presenting empirical evidence on the validity of these measurements where a party wall is present. Two different party wall heat transfer behaviours were observed through heat flux density measurements. Thermal charging is apparent in QUB tests and the initial stages of coheating. After 48 h of coheating, the party wall has become heat saturated and exhibits stable heat transfer. Consequently, using heat flux density measurements to isolate party wall heat transfer in QUB tests, where thermal saturation has not been achieved, can result in misleading inferences. The coheating and QUB measurements without party wall adjustment are in close agreement, irrespective of differing heating patterns in the neighbouring property. The generalisation of these findings is problematic since they describe the impact of the case study-specific built form and the test conditions. Future work to explore the impact of built form and test conditions is needed.