Inicio  /  Applied Sciences  /  Vol: 12 Par: 8 (2022)  /  Artículo
ARTÍCULO
TITULO

Optical Response of Expired EBT3 Film for Absorbed Dose Measurement in X-ray and Electron Beam Range

Maisarah Musa    
Hamad Yahia Abu Mhanna    
Ahmad Fairuz Omar    
Yasmin Md Radzi    
Hanan Fawaz Akhdar    
Nor Hafizah Ishak and Haytham Al Ewaidat    

Resumen

The purpose of this study was to investigate the optical response of an expired External Beam Therapy (EBT3) film, which expired in 2018, using X-rays and electron beam doses. The film?s optical responses were evaluated for its usability in measuring different radiation sources, energy, and absorbed doses ranging up to 5 Gy. Pieces of the expired EBT3 film were irradiated with 90 kVp, 6 MV X-ray photons, and 6 MeV electron beam. The analysis was performed using the Jaz visible spectrometer and EPSON Perfection V370 Photo scanner to obtain the absorbance and the net relative optical density (ROD) of the film samples respectively. The results showed that spectroscopic measurements of the exposed expired EBT3 films under these radiation sources were able to produce primary secondary peaks at ? = 633.52 nm and ? = 582.3 nm respectively. The best wavelength subsets that presented the best MLR regression fitting for all experiments were 541.48 nm, 561.11 nm, and 600.28 nm. While, for the 6 MV photon and the 6 MeV electron beam they were 600.28 nm, 650.79 nm and 654.10 nm. In case of the irradiation with the 6 MV photon and the 6 MeV electron beam, expired EBT3 film showed no significant differences, which made it suitable for dosimetry in various sources of radiation. The individual calibration of radiation dose produces very high measurement accuracy with coefficient of determination, R2 above 0.99 and root mean square of error, RMSE of 0.038 Gy, 0.113 Gy, and 0.115 Gy for films irradiated with 90 kVp X-rays, 6 MV photon beam, and 6 MeV electron beam respectively. Hence, from the results, the expired EBT3 film used in this study showed promising usability of expired EBT3 films beyond their prescribed expiry dates.

 Artículos similares

       
 
Alessandro Zanarini    
Spatially dense operative deflection shapes and receptances, acquired in broad frequency bands, increase the detail in the spatial and frequency domains of the responses of parts in actual dynamic loading, manufacturing and mounting conditions. This work... ver más
Revista: Acoustics

 
Min-Jen Tsai, Ya-Chu Lee and Te-Ming Chen    
QR codes (short for Quick Response codes) were originally developed for use in the automotive industry to track factory inventories and logistics, but their popularity has expanded significantly in the past few years due to the widespread applications of... ver más
Revista: Algorithms

 
Naveed Ur Rehman Junejo, Mariyam Sattar, Saifullah Adnan, Haixin Sun, Abuzar B. M. Adam, Ahmad Hassan and Hamada Esmaiel    
In the past decades, researchers/scientists have paid attention to the physical layer of underwater communications (UWCs) due to a variety of scientific, military, and civil tasks completed beneath water. This includes numerous activities critical for co... ver más

 
Francisco J. P. Rebelo, Joel R. M. Oliveira, Hugo M. R. D. Silva, Jorge Oliveira e Sá, Vânia Marecos and João Afonso    
The evolution of technological tools, namely affordable sensors for data collection, and the growing concerns about maintaining roads in adequate conditions have promoted the development of continuous pavement monitoring systems. This paper presents the ... ver más
Revista: Infrastructures

 
Ming Yang, Haoliang Chang, Jinhuan Chen and Xinyu Zhu    
A photodetector is a type of optoelectronic device with excellent photoelectric conversion abilities, which has especially important applications in many fields such as optical communication, image sensing, aerospace/environmental detection, and military... ver más
Revista: Coatings