Inicio  /  Infrastructures  /  Vol: 8 Par: 9 (2023)  /  Artículo
ARTÍCULO
TITULO

Assessment of Liquefaction Hazard for Sites in Romania Using Empirical Models

Florin Pavel and Robert Vladut    

Resumen

This paper is focused on the evaluation of the liquefaction hazard for different sites in Romania. To this aim, a database of 139 ground motions recorded during Vrancea intermediate-depth earthquakes having moment magnitudes MW = 6.0 is employed for the evaluation of the equivalent number of cycles for this seismic source. Several functional forms for the empirical evaluation of the equivalent number of cycles considering various seismological or engineering parameters are tested and evaluated. The regression analysis shows smaller uncertainties for the empirical models based on ground motion engineering parameters. Considering the lack of information in terms of engineering parameters, a simpler empirical model which accounts for the earthquake magnitude, source?site distance and soil conditions is selected for the liquefaction hazard analysis. Based on the proposed empirical model, specific magnitude scaling factors for Vrancea intermediate-depth earthquakes are proposed for the first time as well. The liquefaction hazard analysis is performed for sites whose seismic hazard is generated by either the Vrancea intermediate-depth seismic source or by local shallow crustal seismic sources. In the case of some of the selected sites, liquefaction phenomena were observed during past large-magnitude earthquakes. Unlike previous studies dealing with liquefaction analyses for sites in Romania, in this research, the hazard assessment is performed for various ground motion levels evaluated based on probabilistic seismic hazard assessment. Liquefaction hazard curves are constructed for each analyzed site. The results of the liquefaction hazard analysis show that this phenomenon is more likely to occur in the areas exposed to Vrancea intermediate-depth earthquakes, compared to the areas affected by local shallow earthquakes. In the case of the analyzed soil profiles from Bucharest, Craiova and Ianca, the minimum liquefaction safety factors less than one even for seismic hazard levels having mean return periods of 100 years and less.

 Artículos similares

       
 
Leiye Wu, Wei Cheng and Zhehao Zhu    
Seabed soil may experience a reduction in strength or even liquefaction when subjected to cyclic loadings exerted by offshore structures and environmental loadings such as ocean waves and earthquakes. A reasonable and robust constitutive soil model is in... ver más

 
Gareth Griffiths, Abul Kalam Hossain, Vikas Sharma and Ganesh Duraisamy    
A number of technological challenges need to be overcome if algae are to be utilized for commercial fuel production. Current economic assessment is largely based on laboratory scale up or commercial systems geared to the production of high value products... ver más

 
Silvia Palacios,Gabriela Lara,Laura Perucca     Pág. 333 - 349
. The earthquakes of 1894, 1944, 1952 and 1977 occurred in the province of San Juan in central-wesern Argentina caused numerous processes of soils and sediment liquefaction, including those in the Ullum-Zonda valley. Historical records showed cracks, san... ver más
Revista: Andean Geology

 
Bambang Setiawan,Mark Jaksa     Pág. 162 - 168
Due to its continuous data recording capability, excellent repeatability and accuracy, relatively low cost and simplicity of operation, the cone penetration test (CPT) offers enhanced liquefaction assessment over its predecessor the standard penetration ... ver más

 
K. Pitilakis, S. Argyroudis, K. Kakderi, J. Selva     Pág. 1335 - 1344
Transportation infrastructures are complex systems of various connected components like bridges, roads, tunnels, embankments, retaining walls in case of a highway system or wharfs, cranes, buildings, utility systems in case of port facilities. Due to the... ver más