Inicio  /  ChemEngineering  /  Vol: 4 Par: 1 (2020)  /  Artículo
ARTÍCULO
TITULO

Column Separation of Am(III) and Eu(III) by a-Zirconium Phosphate Ion Exchanger in Nitric Acid

Elmo W. Wiikinkoski    
Iiro Rautsola    
Junhua Xu and Risto Koivula    

Resumen

The trivalent lanthanide-actinide separations are a major challenge in reprocessing of nuclear fuels. To achieve this, commonly organic extractants and solvents are utilized in elaborate processes. Here we report a simple new method that can perform a supportive or alternative role. A nanocrystalline a-zirconium phosphate ion exchanger was utilized for Eu(III)/Am(III) column separation. Comprehensive preliminary studies were done using batch experiments to optimize the final separation conditions. The distribution coefficients for Eu were determined as a function of pH (from 0 to 3) and salinity (Na, Sr). The distribution coefficients for Am were determined as a function of pH, and Eu concentration, from 1:40 to 10,000:1 Eu:Am molar ratio. The exchanger always preferred Eu over Am in our experimental conditions. Separation factors (Eu:Am) of up to 400 were achieved in binary Eu-Am solution in pH 1. The breakthrough capacity was determined in dynamic column conditions using Eu: 0.3 meq·g-1, which is approximately 4% of the theoretical maximum capacity. Two types of hot column separation tests were conducted: (i) binary load (selective Am elution), and (ii) continuous equimolar binary feed. In both cases separation was achieved. In (i), the majority (82% of the recovered 93%) of Am could be purified from Eu with extremely high 99.999% molar purity, while alternatively even more (95% of the recovered 93%) at a lower purity of 99.7 mol %. In (ii), up to 330 L·kg-1 of the equimolar solution per mass of the exchanger could be treated with Am purity above 99.5 mol % in the total eluate. Alternatively, up to 630 L·kg-1 above 95 mol %, or up to 800 L·kg-1 above 90 mol % purities.

 Artículos similares

       
 
Botond Szilágyi, Do Thi Huyen Trang, Dániel Fózer, Asmaa Selim, Eniko Haáz, András József Tóth     Pág. 364 - 370
The study is motivated by the industrial problem from pharmaceutical industry, which is ethanol and methanol removal from process wastewater. To complete this goal hybrid method is investigated and optimized. Two distillation columns are sufficient for s... ver más

 
Chang-Seob Seo and Hyeun-Kyoo Shin    
Sogunjung-tang (SGJT) is a traditional herbal prescription that has been used in Korea for the treatment of abdominal pain since ancient times. In this study, an analytical method for the simultaneous quantification of 12 marker analytes (gallic acid (GA... ver más
Revista: Applied Sciences

 
Asghar Rezaei, Hugo Giambini, Alan L. Miller II, Xifeng Liu, Benjamin D. Elder, Michael J. Yaszemski and Lichun Lu    
The spinal column is the most common site for bone metastasis. Vertebral metastases with instability have historically been treated with corpectomy of the affected vertebral body and adjacent intervertebral discs, and have more recently been treated with... ver más
Revista: Applied Sciences

 
Anna Somogyi, Mária Berinkeiné Donkó, Farkas Sarnyai, Gergely Becskereki, Miklós Csala, Blanka Tóth     Pág. 421 - 429
A sensitive, reproducible reverse-phased high performance liquid chromatography electrospray tandem mass spectrometry (HPLC-ESI-MS/MS) method with simple sample preparation was developed for the simultaneous determination of a wide range of ceramides, di... ver más

 
Guanghua He, Zhigang Zhang, Wei Wang, Zhengke Wang and Penglin Jing    
The near-trapping phenomenon, which can lead to high wave elevations and large wave drift forces, is investigated by a floating four-column structure. To solve this wave-structure interaction problem, a numerical model is established by combining the wav... ver más