Inicio  /  Instruments  /  Vol: 4 Par: 2 (2020)  /  Artículo
ARTÍCULO
TITULO

Functional Imaging of the Ocular Fundus Using an 8-Band Retinal Multispectral Imaging System

Emanuel R. de Carvalho    
Richelle J. M. Hoveling    
Cornelis J. F. van Noorden    
Reinier O. Schlingemann and Maurice C. G. Aalders    

Resumen

Application of functional imaging in ophthalmology requires efficient imaging techniques that can detect and quantify chromophores to visualise processes in vivo. The aim of the present study was to develop and evaluate a fast and affordable imaging system. We describe an eight-band retinal multispectral imaging (MSI) system and compare it with a hyperspectral imaging (HSI) device. Determination of blood oxygen saturation was studied as proof of principle. Reflectance of incident light is measured as 1/absorbance at different wavelengths between 440 nm and 580 nm. Both devices have incorporated optical bandpass filters in a mydriatic fundus camera. The MSI system scans the retina at eight pre-defined wavelengths specific for the spectrum of haemoglobin. The HSI system acquires a full scan from 480 to 720 nm in 5 nm steps. A simple assessment of the ratio between the absorbance peaks of oxygenated haemoglobin (HbO2) and reduced haemoglobin (HbR) was not suitable for generating validated oxygenation maps of the retina. However, a correction algorithm that compares the measured reflectance with reflectance spectra of fully oxygenated and fully deoxygenated blood allowed our MSI setup to estimate relative oxygen saturation at higher levels, but underestimated relative oxygen saturation at lower levels. The MSI device generated better quality images than the HSI device. It allows customisation with filter sets optimised for other chromophores of interest, and augmented with extrinsic contrast imaging agents, it has the potential for a wider range of ophthalmic molecular imaging applications.

 Artículos similares

       
 
Tong Zhang, Rui Guo, Haolin Zhang, Hongyu Zhou, Yeyu Cao, Maokun Li, Fan Yang and Shenheng Xu    
The change of acoustic velocity in the human thorax reflects the functional status of the respiratory system. Imaging the thorax?s acoustic velocity distribution can be used to monitor the respiratory system. In this paper, the feasibility of imaging the... ver más
Revista: Applied Sciences

 
Jin Xie, Zhiyong Huo, Xianru Liu and Zhishun Wang    
For attention deficit hyperactivity disorder (ADHD), a common neurological disease, accurate identification is the basis for treatment. In this paper, a novel end-to-end representation learning framework for ADHD classification of functional magnetic res... ver más
Revista: Applied Sciences

 
Mohammed Isam Al-Hiyali, Norashikin Yahya, Ibrahima Faye, Maged S. Al-Quraishi and Abdulhakim Al-Ezzi    
The study of functional connectivity (FC) of the brain using resting-state functional magnetic resonance imaging (rs-fMRI) has gained traction for uncovering FC patterns related to autism spectrum disorder (ASD). It is believed that the neurodynamic comp... ver más
Revista: Applied Sciences

 
Jéssica Monteiro, João Castelhano, Duarte Pignatelli, Armando Tartaro and Nicoletta Cera    
Background: Several functional magnetic resonance imaging (fMRI) studies investigated the brain correlates of psychogenic erectile dysfunction (PED) and premature ejaculation (PE), representing the most common sexual dysfunctions in men. These studies al... ver más
Revista: Applied Sciences

 
Genwang Wang, Ye Ding, Haotian Long, Yanchao Guan, Xiwen Lu, Yang Wang and Lijun Yang    
Nano-manipulation technology, as a kind of ?bottom-up? tool, has exhibited an excellent capacity in the field of measurement and fabrication on the nanoscale. Although variety manipulation methods based on probes and microscopes were proposed and widely ... ver más
Revista: Applied Sciences