Redirigiendo al acceso original de articulo en 15 segundos...
Inicio  /  Buildings  /  Vol: 13 Par: 11 (2023)  /  Artículo
ARTÍCULO
TITULO

Indoor Air Quality in Cob Buildings: In Situ Studies and Artificial Neural Network Modeling

Karim Touati    
Mohammed-Hichem Benzaama    
Yassine El Mendili    
Malo Le Guern    
François Streiff and Steve Goodhew    

Resumen

Knowledge of indoor air quality (IAQ) in cob buildings during the first few months following their delivery is of vital importance in preventing occupants? health problems. The present research focuses on evaluating IAQ in cob buildings through a prototype built in Normandy, France. To achieve this, the prototype was equipped with a set of sensors to monitor various parameters that determine indoor and outdoor air quality. These parameters include relative humidity (RH), carbon dioxide (CO2), nitrogen dioxide (NO2), ozone (O3), particulate matter (PM1 and PM10), and volatile organic compounds (VOCs). The obtained experimental results indicate that, overall, there is good indoor air quality in the prototype building. However, there are some noteworthy findings, including high indoor RH and occasional spikes in CO2, PM1, PM10, and VOCs concentrations. The high RH is believed to be a result of the ongoing drying process of the cob walls, while the peaks in pollutants are likely to be attributed to human presence and the earthen floor deterioration. To ensure consistent good air quality, this study recommends the use of a properly sized Controlled Mechanical Ventilation system. Additionally, this study explored IAQ in the cob building from a numerical perspective. A Long Short-Term Memory (LSTM) model was developed and trained to predict pollutant concentrations inside the building. A validation test was conducted on the CO2 concentration data collected on-site, and the results indicated that the LSTM model has accurately predicted the evolution of CO2 concentration within the prototype building over an extended period.

 Artículos similares

       
 
Yeng-Fong Shih, Chun-Wei Chang, Teng-Hsiang Hsu and Wei-Yi Dai    
Wood?plastic composites (WPCs), abbreviated as WPCs, are typically composite materials made by mixing wood flour and thermoplastic resins, and then shaped through processes such as extrusion or compression. They have emerged as a viable and advanced alte... ver más
Revista: Buildings

 
Yanpeng Wu, Meitong Jin and Tianhu Zhang    
Taking the high and large space of the University of Science and Technology Beijing Gymnasium as this research object, this paper analyzes the influence of different window positions, window-to-wall ratio (WWR), solar heat gain coefficient (SHGC), heat t... ver más
Revista: Buildings

 
Hamidi Saidin, Azli Abd Razak, Mohd Faizal Mohamad, Ahmad Zia Ul-Saufie, Sheikh Ahmad Zaki and Nor?azizi Othman    
IAQ is a crucial factor affecting the health, comfort, and productivity of workers, particularly those working in enclosed spaces like bank offices. This study aimed to evaluate the IAQ of a bank office?s operational area and vault by analyzing concentra... ver más
Revista: Buildings

 
Xiaozhou Wu, Hao Gao, Mingming Zhao, Jie Gao, Zhen Tian and Xiangli Li    
A ceiling cooling system integrated with a mechanical ventilation system has been widely used in modern buildings with large sensible cooling loads due to the high thermal comfort level and large energy efficiency. However, there is a lack of systematic ... ver más
Revista: Buildings

 
Seungwoog Jung, Seungwan Han and Hoon Choi    
The comprehensive and accurate assessment of the indoor air quality (IAQ) in large spaces, such as offices or multipurpose facilities, is essential for IAQ management. It is widely recognized that various IAQ factors affect the well-being, health, and pr... ver más