Redirigiendo al acceso original de articulo en 16 segundos...
Inicio  /  Buildings  /  Vol: 13 Par: 3 (2023)  /  Artículo
ARTÍCULO
TITULO

Dynamic Response Modeling of Mountain Transmission Tower-Line Coupling System under Wind?Ice Load

Haoran Song and Yingna Li    

Resumen

Transmission lines have the characteristics of being tall tower structures with a large span distribution of transmission lines that are sensitive to external loads such as wind and ice, and belong to strong, nonlinear, complex, rigid-flexible coupling systems. The force process of the tower-line structure is a combination of instantaneous and continuously stressed, so it is not accurate to judge the safety of the transmission line based only on the operation status of the transmission tower or the conductor. In this paper, a finite element model of three towers and two lines with large span and large elevation differences is established by taking into account the tower-line coupling system. From the static point of view, the static axial force of a single tower and the contribution rate of wind and ice load are analyzed, and the ultimate bearing capacity of a tension-type electric tower is obtained by considering the bending effect and critical initial defects. From the perspective of transient dynamic response, the displacement of the tower-line coupling system under wind?ice load is calculated, and the force characteristics and force transmission process of the straight tower under wind?ice load are observed. Multiple comparison models are set up to compare and analyze the sway and tension under large span and large elevation differences, and the maximum icing thickness of each group model is obtained by repeated trials. The experimental results show that under the tower-line coupling system, the contribution of wind load to the axial force of the main material is 72.92%, and the contribution of wind?ice load to the axial force of main material is 27.6%." role="presentation" style="position: relative;">%.%. % . The maximum increase tension under transient ice-off effect is 59.58%, the ultimate force of the tension tower is 545.5 kN, and the maximum icing thickness of the transmission line under large span and large elevation differences is 28.7 cm, which is slightly larger than the design icing thickness. In conclusion, this paper can provide reference for the construction of mountain transmission towers, power safety inspection, and line health status assessment.

 Artículos similares

       
 
Maryam Badar and Marco Fisichella    
Fairness-aware mining of data streams is a challenging concern in the contemporary domain of machine learning. Many stream learning algorithms are used to replace humans in critical decision-making processes, e.g., hiring staff, assessing credit risk, et... ver más

 
Liliana Andrei and Oana Luca    
Integrating autonomous vehicles (AVs) into urban areas poses challenges for transportation, infrastructure, building, environment, society, and policy. This paper goes beyond the technical intricacies of AVs and takes a holistic, interdisciplinary approa... ver más

 
Yadong Zhu, Haifeng Jiao, Shihui Wang, Wenbo Zhu, Mengcheng Wang and Songshan Chen    
In order to study the pressure pulsation characteristics and structural dynamic response characteristics of a vertical shaft cross-flow pump, this study used a computational fluid dynamics (CFD) numerical simulation method to analyze the pressure pulsati... ver más
Revista: Water

 
Panagiota S. Katsimpini    
The aim of this study is to investigate the seismic behavior of concrete/steel mixed structures. In engineering praxis, many buildings consist of two parts: one made of reinforced concrete and the other made of steel. There are several difficulties in th... ver más
Revista: Buildings

 
Sipho G. Thango, Georgios A. Drosopoulos, Siphesihle M. Motsa and Georgios E. Stavroulakis    
A methodology to predict key aspects of the structural response of masonry walls under blast loading using artificial neural networks (ANN) is presented in this paper. The failure patterns of masonry walls due to in and out-of-plane loading are complex d... ver más
Revista: Infrastructures