Redirigiendo al acceso original de articulo en 21 segundos...
Inicio  /  Infrastructures  /  Vol: 7 Par: 3 (2022)  /  Artículo
ARTÍCULO
TITULO

Identification of Stop Criteria for Large-Scale Laboratory Slab Tests Using Digital Image Correlation and Acoustic Emission

Christian Overgaard Christensen    
Fengqiao Zhang    
Gabriela Zarate Garnica    
Eva Olivia Leontien Lantsoght    
Per Goltermann and Jacob Wittrup Schmidt    

Resumen

Advanced monitoring methods are required to identify stop criteria in proof-load tests. In this study, the combined methodology of two-dimensional digital image correlation and acoustic emission is investigated for its applicability for future implementation in field tests. The two monitoring systems are deemed to provide valuable insight with external measurements from digital image correlation and internal measurements from acoustic emission. Two overturned T-section reinforced concrete slabs (0.37 × 1.7 × 8.4 m) tested under laboratory conditions are used for the assessment. The first slab test served as a preliminary test to enable sensor placement and creation of a relevant loading protocol. The main scientific results lead to a proposal for a test procedure using the combined methodology based on results, observations, and experiences from an individual stop criteria assessment for the two methods. The results include full-field plots, an investigation of the time of crack detection and monitoring of crack widths with digital image correlation, and a qualitative assessment of activity vs. load followed by a quantitative evaluation of calm ratios using acoustic emission. The individual results show that both digital image correlation and acoustic emission can identify damage occurrence earlier than other secondary methods. At crack detection (415 kN), crack widths were measured at widths between 0.078 mm to 0.125 mm and can be monitored until reaching the stop criterion at 463 kN (Eurocode SLS threshold of wmax = 0.2 mm). The acoustic emission results were limited by the pre-defined loading protocol and thus, only indicated that damage occurred sometime between 300 kN and 500 kN (pre-defined load levels). Therefore, the proposal for test procedure involves a methodology, where the loading protocol may be updated during testing based on monitoring results and thus provide even more valuable data.

 Artículos similares

       
 
Andrei Tevyashev,Olga Matviyenko,Glib Nikitenko     Pág. 29 - 38
We have constructed a stochastic model of a water supply network with leaks, which, compared to the previously proposed models (excluding leaks), more adequately describes the processes of transportation and water distribution in water supply systems. Ma... ver más

 
Steffen Axer, Bernhard Friedrich     Pág. 1645 - 1661
The objective of this paper is the development of a staged methodology that allows the estimation of signal timing information like cycle length, green and red time intervals for time-dependent fixed-time controlled and actuated intersections based on fl... ver más

 
Ric Romero and Emmanouil Mourtzakis    
Cognitive radar (CRr) is a recent radar paradigm that can potentially help drive aerospace innovation forward. Two specific platforms of cognitive radar used for target identification are discussed. One uses sequential hypothesis testing (SHT) in the rec... ver más
Revista: Aerospace