ARTÍCULO
TITULO

Influence of Implant Number on Peri-Implant and Posterior Edentulous Area Strains in Mandibular Overdentures Retained by the New Ti?Zr (Roxolid®) Mini-Implants as Single-Units: In Vitro Study

Dario Puljic    
Asja Celebic    
Ines Kovacic and Nikola Petricevic    

Resumen

The new Ti?Zr (Roxolid®) mini-implants have not yet been fully researched. We analyzed peri-implant and posterior edentulous area microstrains during mandibular overdenture (OD) loading at different sites with different extents of forces when one-, two-, three-, or four- mini dental implants (MDIs) as single-units supported the respective ODs. The models were designed from cone beam computed tomography (CBCT) scans of an appropriate patient with narrow ridges. The mucosal thickness was 2 mm. Strain gauges were bonded on the vestibular and oral peri-implant sites, and in the distal edentulous area under the saddles. The loads were applied posteriorly bilaterally and unilaterally with 50, 100 and 150 N forces, and anteriorly with 50 and 100 N forces. Each loading was repeated 15 times. Statistical analysis included descriptive statistics, boxplots and the MANOVA. Higher forces induced higher peri-implant microstrains, as well as unilateral loadings, especially on the loaded side, in all models except the one-MDI model where anterior loads (100 N) elicited the highest peri-implant microstrain (1719.35 ± 76.0). The highest microstrains during unilateral posterior loading (right side) with 150 N force were registered from the right MDI in the two-MDI model (1836.64 ± 63.0). High microstrains were also recorded on the left side (1444.48 ± 54.6). By increasing the number of implants, peri-implant microstrains and those in the edentulous area decreased. In the three- and four-MDI models, higher microstrains were found in the posterior than in the anterior MDIs under posterior loadings. None of the recorded microstrains exceeded bone reparatory mechanisms, although precaution and additional research should be provided when only one or two MDIs support ODs.

 Artículos similares

       
 
Joseph Attias, Navid Shahnaz, Chamutal Efrat, Brian Westerberg, Jane Lea, Eytan David, Ofir Zavdy and Ohad Hilly    
Objectives?Cochlear implantation has been suggested to be associated with an air-bone gap, possibly secondary to increased middle- and inner-ear stiffness. To explore the effect of possible changes in mechanics due to cochlear implantation, we measured w... ver más
Revista: Applied Sciences

 
Jessica Hembus, Felix Ambellan, Stefan Zachow and Rainer Bader    
Currently, new materials for knee implants need to be extensively tested but such tests are expensive in a knee wear simulator in a realized design. However, using a rolling-sliding test bench, these materials can be examined under the same test conditio... ver más
Revista: Applied Sciences

 
María Bufalá Pérez, Miriam O?Connor Esteban, Álvaro Zubizarreta-Macho, Elena Riad Deglow, Sofía Hernández Montero, Francesc Abella Sans and Alberto Albaladejo Martínez    
To analyze the influence of the operator experience on the accuracy of orthodontic self-tapping micro-screws placement, a total of 60 orthodontic self-tapping micro-screws were randomly distributed into two study groups: Group A. Orthodontic micro-screws... ver más
Revista: Applied Sciences

 
Piotr Kosior, Piotr Kuropka, Maciej Janeczek, Marcin Mikulewicz, Wojciech Zakrzewski and Maciej Dobrzynski    
The purpose of this study was to present the level of bone tissue deformation after drilling under variable conditions in three different dental implant systems in a microscopic analysis. Straumann, Osstem, and S-Wide systems were used to drill boreholes... ver más
Revista: Applied Sciences

 
Woon-Man Kung, I-Shiang Tzeng and Muh-Shi Lin    
In patients suffering from severe traumatic brain injury and massive stroke (hemorrhagic or ischemic), decompressive craniectomy (DC) is a surgical strategy used to reduce intracranial pressure, and to prevent brainstem compromise from subsequent brain e... ver más
Revista: Applied Sciences