Redirigiendo al acceso original de articulo en 22 segundos...
Inicio  /  Applied Sciences  /  Vol: 12 Par: 2 (2022)  /  Artículo
ARTÍCULO
TITULO

A Fluid Inclusion and Critical/Rare Metal Study of Epithermal Quartz-Stibnite Veins Associated with the Gerakario Porphyry Deposit, Northern Greece

Christos L. Stergiou    
Vasilios Melfos    
Panagiotis Voudouris    
Lambrini Papadopoulou    
Paul G. Spry    
Irena Peytcheva    
Dimitrina Dimitrova and Elitsa Stefanova    

Resumen

The Gerakario Cu-Au porphyry deposit in the Kilkis ore district, northern Greece, contains epithermal quartz-stibnite veins on the eastern side of the deposit, which crosscut a two-mica gneiss. Metallic mineralization in these veins consists of stibnite + berthierite + native antimony + pyrite + arsenopyrite, and minor marcasite, pyrrhotite, chalcopyrite, löllingite, and native gold. Bulk geochemical analyses of the ore reveal an enrichment in critical and rare metals, including Ag, Au, Bi, Ce, Co, Ga, La, and Sb. Analysis of stibnite with LA-ICP-MS showed an enrichment in base metals (As, Cu, Pb), as well as weak to moderate contents of critical and rare metals (Ag, Bi, Ce, La, Re, Sm, Th, Ti, Tl). A statistical analysis of the trace elements show a positive correlation for the elemental pairs Ce-La, Ce-Sb, and La-Sb, and a negative correlation for the pair Bi-Sb. Fluid inclusions in the A-type veins of the porphyry-style mineralization show the presence of fluid boiling, resulting in a highly saline aqueous fluid phase (35.7 to 45.6 wt.% NaCl equiv.) and a moderately saline gas phase (14 to 22 wt.% NaCl equiv.) in the system H2O-NaCl-KCl at temperatures varying between 380° and 460 °C and pressures from 100 to 580 bar. Mixing of the moderate saline fluid with meteoric water produced less saline fluids (8 to 10 wt.% NaCl equiv.), which are associated with the epithermal quartz-stibnite vein mineralization. This process took place under hydrostatic pressures ranging from 65 to 116 bar at a depth between 600 and 1000 m, and at temperatures mainly from 280° to 320 °C.

 Artículos similares

       
 
Petr Vrchota, Ale? Prachar and Pavel Hospodár    
Inclusion of Active Flow Control (AFC) into Computational Fluid Dynamics (CFD) simulations is usually highly time-consuming and requires extensive computational resources and effort. In principle, the flow inside of the fluidic AFC actuators should be in... ver más
Revista: Aerospace

 
Frank Böhnke    
The ear is able to detect low-level acoustic signals by a highly specialized system including a parametric amplifier in the cochlea. This is verified by a numerical mechanical model of the cochlea, which reduces the three-dimensional (3D) system to a one... ver más
Revista: Acoustics

 
Marieli Azoia Lukiantchuki, Alessandra Prata Shimomura, Fernando Marques da Silva, Rosana Maria Caram (Author)     Pág. e37537
 Wind tunnel experiments and Computational Fluid Dynamics (CFD) simulations are used to analyze natural ventilation in a sawtooth roof building. A 1:10 scale model is tested in an atmospheric boundary layer wind tunnel. The CFD simulations are perfo... ver más