Redirigiendo al acceso original de articulo en 16 segundos...
Inicio  /  Information  /  Vol: 14 Par: 2 (2023)  /  Artículo
ARTÍCULO
TITULO

Multi-Morphological Pulse Signal Feature Point Recognition Based on One-Dimensional Deep Convolutional Neural Network

Guotai Wang    
Xingguang Geng    
Lin Huang    
Xiaoxiao Kang    
Jun Zhang    
Yitao Zhang and Haiying Zhang    

Resumen

Radial pulse signals are produced by the periodic ejection of blood from the heart, and physiological and pathological information of the human body can be analyzed by extracting the time-domain characteristics of pulse waves. However, since pulse signals are weak physiological signals on the body surface and complex, the acquisition of pulse characteristics using the traditional curvature method will produce a large error, which cannot meet the needs of pulse wave analysis in current clinical practice. To solve this problem, a multi-morphological pulse signal feature recognition algorithm based on the one-dimensional deep convolutional neural network (1D-DCNN) model is proposed. We used the multi-channel pulse diagnosis instrument independently developed by the team to collect radial pulse signals under continuous pressure of the test subjects and collected 115 subjects and extracted a total of 1300 single-cycle pulse signals and then divided these pulse signals into 6 different forms. Five types of pulse signal time-domain feature points were labeled, and five independent feature point datasets were labeled and formed five customized neural network models that were generated to train and identify the pulse feature point datasets independently. The results show that the correction coefficient (Radjusted2" role="presentation">??2????????????????Radjusted2 R a d j u s t e d 2 ) of the multi-class pulse signal processing algorithm proposed in this paper for each type of feature point recognition reaches more than 0.92. The performance is significantly better than that of the traditional curvature method, which shows the accuracy and superiority of the proposed method. Therefore, the multi-class pulse signal characteristic parameter recognition model based on the 1D-DCNN model proposed in this paper can efficiently and accurately identify pulse time-domain characteristic parameters, which can be applied to discriminate time-domain pulse information in clinical practice and assist doctors in diagnosis.

 Artículos similares

       
 
Yongjiang Mao, Wenjuan Ren, Xipeng Li, Zhanpeng Yang and Wei Cao    
With the progress of signal processing technology and the emergence of new system radars, the space electromagnetic environment becomes more and more complex, which puts forward higher requirements for the deinterleaving method of radar signals. Traditio... ver más
Revista: Applied Sciences

 
Michal Tu?er, Marek Brabec, Helge Balk, Vladislav Dra?tík, Jan Kubecka and Jaroslava Frouzová    
Fish body orientation significantly influences the size obtained with hydroacoustic signals, and thus the estimate of fish size and biomass. For this reason, each characteristic of a target?s echo can be advantageous for developing algorithms to refine a... ver más
Revista: Water

 
Brian G. Sanderson, Richard H. Karsten and Daniel J. Hasselman    
An area has been designated for demonstrating the utility of marine hydrokinetic turbines in Minas Passage, Bay of Fundy. Marine renewable energy may be useful for the transition from carbon-based energy sources, but there is concern for the safety of fi... ver más

 
Hong Je-Gal, Seung-Jin Lee, Jeong-Hyun Yoon, Hyun-Suk Lee, Jung-Hee Yang and Sewon Kim    
Ensuring operational reliability in machinery requires accurate fault detection. While time-domain vibration pulsation signals are intuitive for pattern recognition and feature extraction, downsampling can reduce analytical complexity, but may result in ... ver más

 
Yuan Liu, Jian Tang, Chen Feng, Chen Zhang, Yuwei Xue, Lei Zhang, Shuxi Xu, Jian Wang, Fang Dai and Ning Wang    
Based on equal precision frequency measurement and pulse counting technique, a multi-period synchronous frequency measurement method is proposed in this paper. A programmed cymometer is designed with a full frequency band with equal precision measurement... ver más
Revista: Applied Sciences