Outdoor Air Quality and Antibiogram Characteristics of Bacterial Isolates of Akure City Abattoirs, Nigeria

Authors

  • Olubukola Olayemi Olusola-makinde Department of Microbiology, School of Sciences, Federal University of Technology, Akure

DOI:

https://doi.org/10.21467/ias.9.1.33-40

Abstract

Air sampling of Onyearugbulem and FUTA abattoirs was carried out to evaluate their quality. Air sampling was done using the open-settling method on general and selective agar media of the gutter, sleeping bench, slaughtering floor dumpsite, slaughtering table and roof of the abattoirs.  Using standard methods, Presumptive identification of the bacterial isolates was carried out. An array of ten (10) conventional antibiotics was used to assay the antibiotic susceptibility characteristics of the bacterial isolates. Multiple antibiotic sensitivity index (MARI) was determined for isolated bacteria. At Onyearugbulem abattoir, the total Escherichia coli count ranged from 3.6×10 cfu/ml from the gutter and slaughtering table to 6.5×10 cfu/ml from the slaughtering floor, while the total bacterial count ranged from 1.34×102 cfu/ml from dumpsite to 2.55×102 cfu/ml from the gutter, the total coliform count ranged from 2.8× 10 cfu/ml from slaughtering floor to 4.1×10 cfu/ml from sleeping bench. Several bacteria were presumptively isolated. These include: Micrococcus sp., Bacillus sp., Staphylococcus aureus, Escherichia coli, Proteus sp., Enterobacter aerogenes and Aeromonas sp. Ciprofloxacin (10 µg) had an inhibitory effect on all the Gram positive bacterial isolates with the highest inhibitory activity on S. aureus at 24.00 mm, and the Gram negative bacteria with the highest inhibitory activity on E. coli at 21.00 mm. Micrococcus sp. had the highest MARI of 0.8. These findings reveal the presence of multiple-antibiotic resistant bacteria in Onyearugbulem and FUTA abattoirs’ atmosphere. There is therefore need for routine environmental sanitation of the slaughterhouses.

Keywords:

abattoir, air quality, bacterial occurrence, conventional antibiotics, multiple antibiotic resistance

Downloads

Download data is not yet available.

References

Z. Andualem, Z, Gizaw, L. Bogale and H. Dagne, “Indoor bacterial load and its correlation to physical indoor air quality parameters in public primary schools,” Multidiscipl Resp Med, 14, 2, 1-7, January 2019.

H. M. Haynes, CRC Handbook of Chemistry and Physics, 97th edn. CRC Press, 2016–2017. ISBN-13: 978-1498754286

P. Srikanth, S. Sudharsanam and R. Steinberg. “Bio-Aerosols in Indoor Environment: Composition, Health Effects and Analysis,” Indian J Med Microbiol, 26, 4, 302-312, October 2008.

V. Patella, G. Florio, D. Magliacane, A. Giuliano, M. A. Crivellaro and D. Di Bartolomeo, “Urban air pollution and climate change: “the Decalogue: allergy safe tree” for allergic and respiratory diseases care.” Clin Mol Allergy, 16, 20, 1-12, September 2018.

J. M. Willey, L. M. Sherwood and C. J. Woolverton. Prescott, Harley, and Klein’s Microbiology, NY, McGraw Hill, 2008.

H. Neboh, O. Ilusanya, C. Ezekoye and F. Orji, “Assessment of Ijebu Igbo Abattoir effluent and its impact on the ecology of the receiving soil and river.” J Envtl Sci Tox Food Tech, 7, 5, 61-67, November 2013.

S. Cabo Verde, S. M. Almeida, J Matos, D. Guerreiro, M. Meneses, T. Faria, D. Botelho, M. Santos and C. Viegas, “Microbiological assessment of indoor air quality at different hospital sites.” Res. Microbiol, 166, 557-563, September 2015.

F. O. Omoya, J. O. Obameso and T. A. Olukibiti, “Evaluation of Bacterial Composition of the Aerosol of Selected Abattoirs in Akure, South Western Nigeria,” Intl J Bioengr L Sci, 8(4), 356-358, March 2014.

Y. Titilawo, L. Obi and A. Okoh, “Antimicrobial resistance determinants of Escherichia coli isolates recovered from some rivers in Osun State, South-Western Nigeria: Implications for public health,” Sci of the Total Envt, 523, 82–94, April 2015.

B. C. Iweriebor, S. Gaqavu, L. C. Obi, U. U. Nwodo and A. I. Okoh, “Antibiotic Susceptibilities of Enterococcus Species Isolated from Hospital and Domestic Wastewater Effluents in Alice, Eastern Cape Province of South Africa.” Intl J Envtl Res Pub Health, 12, 4231-4246, April 2015.

J. F. Lindahl and D. Grace, The consequences of human actions on risks for infectious diseases: a review, Inf ecol epi, 5, 30048-30058, November 2015.

P. O. Olutiola, O. Famurewa and H. G. Sonntag, “Introduction to General Microbiology: A practical approach.” 2nd edn, Bolabay Publication. 2000.

G. Cheesbrough, Principles of sanitation. 3rd edn. Chapman and Hall, London. 2006.

J. G. Cappuccino and N. Sherman, Microbiology: A Laboratory Manual, 8th edn Pearson, USA. 2008.

Clinical Laboratory Standard (CLSI), Performance Standards for Antimicrobial Susceptibility Testing: Twenty-Fourth Informational Supplement, CLSI document M100-S24. Wayne, PA: Clinical and Laboratory Standards Institute, 2014.

M. M. Mahroop Raja and S. John. “Multidrug Resistance Profile of Urinary Tract Infected Gram Positive Pathogenic Bacterial Isolates,” Intl J Infect, 2, 1, 22774-22779, January 2015.

K. J. Ryan and C. G. Ray, 4th edn, Sherris Medical Microbiology. McGraw Hill. 2004.

O. O. Adekolurejo, G. T. Osho and A. Bakare, “Microbial Evaluation of Different Cleaning Techniques on Meat Contact Surfaces in an Abattoir in Akure, Nigeria,” Appl Trop Agric, 21, 3, 223-228, December 2016.

D. F. Maron, T. J. Smith and K. E. Nachman. Restrictions on antimicrobial use in food animal production: an international regulatory and economic survey. Glob Health, 9, 9-48, October 2013.

C. H. Kang, Y. Shin, W. Kim, Y. Kim, K. Song, E. G. Oh, S. Kim, H. Yu and J. S. So. Prevalence and antimicrobial susceptibility of Vibrio parahaemolyticus isolated from oysters in Korea, Envtl Sci Poll Res Intl, 23, 918–926, January 2016.

Downloads

Published

2019-11-16

Issue

Section

Research Article

How to Cite

[1]
O. O. Olusola-makinde, “Outdoor Air Quality and Antibiogram Characteristics of Bacterial Isolates of Akure City Abattoirs, Nigeria”, Int. Ann. Sci., vol. 9, no. 1, pp. 33–40, Nov. 2019.