A simulated case study of a library in Brazil to improve energy efficiency

  • Melanie Gissel Urdangarín Gamarra Universidade Estadual do Oeste do Paraná
  • Jair Antonio Cruz Siqueira Universidade Estadual do Oeste do Paraná
  • Fabyo Luiz Pereira Universidade Federal de Integração da América Latina
Keywords: building simulation; energy-saving; mini-split air-conditioner; vrf; solar control films; feasibility analysis.

Abstract

The aim of this study is to quantify the energy savings of a library in the city of Foz do Iguaçu/Brazil, through simulations in EnergyPlus. Due to the great participation of air conditioning in the electric consumption of the building under study, the following proposals were studied: the exchange of the current split air conditioning units by a Variable Refrigerant Flow (VRF) system; the application of solar control films on the glasses; and both options together. The methodology followed these steps: firstly, it was simulated the current electricity consumption and the results were validated with real measures; secondly, the retrofitting measures were sized and implemented in the program and the energy savings were quantified; finally, an economic analysis was performed in order to determine the feasibility of the proposals. As a result, the VRF system showed an annual saving in air-conditioning of 42.08% related to the mini-split system. The annual electricity savings were 32.01, 2.14 and 32.80% for the VRF, solar control films, and both options together, respectively. The feasibility analysis of the VRF, considering financing and for a scenario consistent with the historical average growth of the electricity prices and inflation rate, showed that the use of a VRF instead of the splits units recovers the initial investment in 14 years. The application of solar control films proved to be economically unfeasible.

Downloads

Download data is not yet available.

Author Biography

Jair Antonio Cruz Siqueira, Universidade Estadual do Oeste do Paraná

The aim of this study is to quantify the energy savings of a library in the city of Foz do Iguaçu/Brazil, through simulations in EnergyPlus. Due to the great participation of air conditioning in the electric consumption of the building under study, the following proposals were studied: the exchange of the current split air conditioning units by a Variable Refrigerant Flow (VRF) system; the application of solar control films on the glasses; and both options together. The methodology followed these steps: firstly, it was simulated the current electricity consumption and the results were validated with real measures; secondly, the retrofitting measures were sized and implemented in the program and the energy savings were quantified; finally, an economic analysis was performed in order to determine the feasibility of the proposals. As a result, the VRF system showed an annual saving in air-conditioning of 42.08% related to the mini-split system. The annual electricity savings were 32.01, 2.14 and 32.80% for the VRF, solar control films, and both options together, respectively. The feasibility analysis of the VRF, considering financing and for a scenario consistent with the historical average growth of the electricity prices and inflation rate, showed that the use of a VRF instead of the splits units recovers the initial investment in 14 years. The application of solar control films proved to be economically unfeasible.

Published
2020-02-28
How to Cite
Gamarra, M. G. U., Siqueira, J. A. C., & Pereira, F. L. (2020). A simulated case study of a library in Brazil to improve energy efficiency. Acta Scientiarum. Technology, 42(1), e47262. https://doi.org/10.4025/actascitechnol.v42i1.47262
Section
Mechanical Engineering

 

0.8