Redirigiendo al acceso original de articulo en 19 segundos...
ARTÍCULO
TITULO

Performance analysis of a vapour compression-absorption cascaded refrigeration system with undersized evaporator and condenser

Vaibhav Jain    
Gulshan Sachdeva Sachdeva    
Surendra S Kachhwaha    

Resumen

In a present study, the performance of a vapour compression?absorption cascaded refrigeration system (CRS) under fouled conditions was analysed. The main effect of fouling is to decrease the effectiveness of the heat exchanger. Thus, the overall conductance (UA) of the heat exchanger is decreased. Hence, another interpretation of fouling is to reduce the effective size of the heat exchanger. In the present work, the percentage decrease in the overall conductance value (UA) of evaporator and condenser due to their fouling is varied from 0 to 50% and its consequences on various aspects of CRS are generated to ascertain any possible patterns. The detailed first law analysis reveals that for a clean evaporator and condenser, the electricity consumption is 67.5% less than vapour compression system (VCS) for the same cooling capacity. CRS is able to save only 61.3% of electrical energy when evaporator and condenser conductance is reduced by 50% due to fouling. Evaporator and condenser fouling decreased the COP and rational efficiency of the system by 4.7% and 10.5% respectively. It is also important to note that irreversibility in the evaporator and condenser is increased by 42.4% and 62.1% respectively, when their individual performance is degraded by 50% due to fouling.

 Artículos similares

       
 
Eduardo Roberto Gutiérrez Gualotuña,Juan Carlos Almeida Mera,José Arzola Ruiz     Pág. 212 - 222
En el trabajo se presentan resultados investigativos obtenidos por los autores en el modelado de indicadores de desempeño de la operación de instalaciones de gasificación de la biomasa con ayuda de redes neuronales artificiales, a partir de la clasificac... ver más

 
José Andrés Pico Gordón,Jorge André Soria Amancha,Eduardo Roberto Gutierrez Gualotuña,José Arzola Ruiz     Pág. 138 - 147
En el trabajo se presentan resultados investigativos obtenidos por los autores en el modelado de indicadores de desempeño de la operación de instalaciones de gasificación de la biomasa con ayuda de las técnicas de regresión no lineal, a partir de la clas... ver más

 
Faisal Ansori,Edi Widodo     Pág. 79 - 86
The pump is a tool to provide the mechanical energy to the liquid in the pump constant fluid density and large. In terms of mechanism, the pump is divided into three types, namely, rotary pumps, pump the shaft/piston and centrifugal pumps. The use of the... ver más

 
Ana Gracia Amillo, Lucky Ntsangwane, Thomas Huld, Jörg Trentmann    
This study compares the performance of two satellite-based solar radiation methodologies for estimating the solar resource available in South Africa. Data from thirteen stations distributed in six climatic regions were considered. More than one year of h... ver más

 
Boris Alba Valle,Orestes Hernández Areu     Pág. 65 - 75
Los pararrayos de óxido de zinc (MOSA) son dispositivos utilizados en la protección contra sobretensiones.Actualmente se han desarrollado modelos matemáticos como herramientas de simulación para un mejor análisis delcomportamiento de los MOSA en estudios... ver más