Redirigiendo al acceso original de articulo en 17 segundos...
ARTÍCULO
TITULO

Calculation of the composite timber­reinforced­concrete bending elements considering the nonlinear work of the joint

Svitlana Shekhorkina    
Mykola Savytskyi    
Tetiana Nikiforova    
Kostiantyn Shliakhov    
Anastasiia Myslytska    

Resumen

A method has been proposed to calculate the composite timber-concrete bending elements taking into consideration the non-linear work of a nail joint and the stretched reinforcement in a slab. An acting building code regulates the structure estimation based on the linear-elastic work while the pattern of the joint's deformation under loading demonstrates a pronounced non-linear character. Estimation formulae do not account for the presence of reinforcement in a concrete slab, which leads to the irrational use of the structure's load-bearing properties.A dependence has been proposed to determine the slip modulus. The determining coefficients are computed based on the rated characteristics given in the acting design standards.An algorithm for calculating the composite timber-concrete bending structures has been given, taking into consideration the deformation diagram of the joint and reinforcement in the stretched zone of a concrete element.It has been established that the normal stresses for the considered variants of timber-concrete beams, determined on the basis of the proposed procedure and the linear-elastic model, differ by 1?8 %. At loads corresponding to plastic deformations, those stresses that were estimated in line with the linear-elastic model prove to be understated. At loads exceeding 0.75 kN/m for the beam with a span of 3 m, and 0.5 kN/m for the beam with a span of 5 m, stresses in the stretched region of a concrete slab exceed the concrete stretching strength while the stresses in a timber beam do not reach the ultimate values. In fact, in this case, the structure's load-bearing capacity is underutilized because the stretching effort in the cross-section with a crack is accepted by the reinforcement.Based on the design features of timber-concrete floors (the thickness of a slab and protective layer), an analysis of the load-bearing capacity considering the reinforcement has been performed. It has been established that the load-bearing capacity of a slab ensures that an estimated bending momentum is tolerated up until the loads that cause the destruction of the timber beam. At the same time, the conditions for the rational operation of compressed concrete and stretched reinforcement are met

 Artículos similares

       
 
Ho-Jin Baek, Ju-Seong Jung, Kang-Seok Lee and Bok-Gi Lee    
This study proposes a concrete-filled tube composite strengthening system (CCSS), which is a new concept that can improve and supplement the vulnerability of existing CFT seismic strengthening methods. The CCSS seismic reinforcement method is easy to con... ver más
Revista: Applied Sciences

 
Jaewon Jang, Maydison, Yeonjun Kim, Zhiqiang Han and Daekyun Oh    
Defects such as voids in composite materials often degrade the mechanical properties of laminates. Even if these materials are manufactured based on the design requirements, there is a possibility of instability occurring in these composite structures. I... ver más

 
Yingna Liang, Cunyuan Wang, Wei Wang, Hao Xing, Zhepeng Zhang and Dianrong Gao    
The slipper pair is the crucial friction pair of the seawater axial piston pump. Taking seawater as the working medium will inevitably affect the bearing performance of the slipper pair. In this paper, a seawater axial piston pump slipper pair model with... ver más

 
Kangkang Shi, Dongsheng Li, Dongsen Hu, Qi Shen and Guoyong Jin    
The acoustic absorption characteristics of anechoic coatings attached to the surface of underwater vehicles are closely related to their acoustic stealth. Owing to the essential property of local resonance, the narrow sound-absorption band cannot meet th... ver más

 
Xiaojun Ke, Wannian Xiang, Xiuning Peng and Yu Dan    
Concrete-encased concrete-filled steel tube (CFST) composite columns provide high bearing capacity, good seismic performance and an easier connection with arbitrary angle beams, which are widely used in high-rise buildings. Considering the high frequency... ver más
Revista: Applied Sciences