Evaluation of the coefficient of performance of an air source heat pump unit and an air to water heat pump

S. Tangwe    
K. Kusakana    

Resumen

Air source heat pump (ASHP) water heaters are efficient devices for sanitary hot water heating. The coefficient of performance (COP) of the air to water heat pump (AWHP) is constantly lower than that of the corresponding ASHP unit. The study focused on determining the COP of both the ASHP unit and the AWHP. This was achieved by the implementation of both experimental and simulation methods, with the help of a data acquisition system and the REFPROP software. The system comprised of a 1.2 kW split type ASHP unit and a 150 L high pressure geyser. A power meter, flow meters, temperature sensors, pressure sensors, ambient temperature and relative humidity sensor were installed at precise locations on the split type AWHP. Controlled volumes of 150, 50 and 100 L were drawn off from the AWHP during the morning, afternoon and evening for a year. The average COP for the summer and winter, in terms of the input electrical and output thermal energies of the AWHP were 3.02 and 2.30. The COPs of the ASHP unit, in terms of the change in the enthalpies of the refrigerant at the inlet and the outlet of the condenser and the evaporator, were 3.52 and 2.65 respectively. The study showed that the difference between the COP of the ASHP unit and that of the AWHP could be ascribed to the electrical energy consumed by the fan and the water circulation pump during the vapour compression refrigeration cycles. The work provides an energy optimisation opportunity to the manufacturers of this technology, helping to enhance the efficiency and COP of ASHP water heaters.HighlightsThe COPt of the ASHP unit was higher than the COPe of the AWHP.The COPe of the AWHP was the ratio of the input electrical energy consumed and the output thermal energy gained by the stored water.The COPt of the ASHP unit was enthalpies-dependent and a function of inlet and outlet enthalpies of the evaporator and condenser.The inlet and outlet refrigerant temperatures profiles of the condenser confirmed thermal energy dissipation.

 Artículos similares

       
 
José Antonio Romero Paguay,Tania Carbonell Morales     Pág. 143 - 152
Un estudio comparativo de un sistema de refrigeración solar simple efecto LiBr por absorción y un sistema de enfriamiento conrueda desecante usando energía solar es presentado. El estudio se realiza mediante la simulación dinámica de estos sistemas enun ... ver más

 
Denis Okello, Ole J Nydal, Karidewa Nyeinga, Eldad J K Banda    
Solar energy is available in an intermittent way, and integrating an energy storage system with solar energy collection devices may promote uninterrupted supply of energy in the absence of the availability of solar energy. It has been shown that heat can... ver más

 
Edmund C. Okoroigwe, Evidence C. Ndu, Florence C. Okoroigwe    
A solar biomass hybrid dryer intially designed with a front pass flat plate solar air heater and a biomass heating stove was redesigned, reconstructed in order to minimize the excessive convective heat losses and its performance re-evaluated. Due to poor... ver más

 
Stephen Tangwe, Michael Simon, Edson L. Meyer, Sampson Mwampheli, Golden makaka    
In South Africa, there is an ongoing constraint on the electricity supply at the national grid to meet the demand. Eskom is implementing various measures such as the Integrated Demand Management and the promotion and encouragement of the use of energy ef... ver más

 
Michel Errasti Cabrera,Antonio Werner de Dios Ortega,Andy Amaury Sánchez Rodríguez,Carlos Fernández-Aballí Altamirano     Pág. 50 - 60
El presente trabajo tiene como objetivo realizar el diseño de un horno que permitirá la combustión controlada de la cáscara de arroz para obtener una ceniza con propiedades puzolánicas; el cual es un producto demandado para la elaboración de materiales r... ver más