Redirigiendo al acceso original de articulo en 24 segundos...
Inicio  /  Water  /  Vol: 8 Núm: 10 Par: 0 (2016)  /  Artículo
ARTÍCULO
TITULO

Domestic Wastewater Depuration Using a Horizontal Subsurface Flow Constructed Wetland and Theoretical Surface Optimization: A Case Study under Dry Mediterranean Climate

Pedro Andreo-Martínez    
Nuria García-Martínez    
Luis Almela    

Resumen

The wastewater generated by isolated houses without access to public sewers can cause environmental problems, like the contamination of aquifers with nitrates and phosphates, as occurs in southeastern Spain. The effectiveness of a previously built horizontal subsurface ?ow constructed wetland (HF-CW) was studied over two years as a possible solution. This HF-CW measured 27 m2; it was planted with Phragmites australis(Cav.) Trin. Ex Steuds sp. Altissima and the parameters studied were those required by European Union (EU) legislation and adopted by Spain. Average abatement ef?ciency rates, for the ?rst and the second year of study, were: biochemical oxygen demand over ?ve days (BOD5) (96.4%, 92.0%), chemical oxygen demand (COD) (84.6%, 77.7%), total suspended solids(TSS) (94.8%,89.9%),total nitrogen(TN)(79.5%,66.0%),ammonium nitrogen(NH4+-N)(98.8%, 86.6%) and total phosphorous (TP) (83.7%, 82.8%). Average abatement ef?ciency for nitrate nitrogen (NO3--N) (-1280.5%, -961.1%) and nitrite nitrogen (NO2--N) (-5.8%, -40.0%) were negative because its content in in?uent wastewater was very low and they appear mainly from in?uent NH4+-N, as a result of puri?cation processes carried out in the HF-CW bed. The abatement rates make the system suitable to produce discharges into the environment in accordance with Spanish law. It is noteworthy that the HF-CW patch suffered an episode of bed drying during the summer of 2013, whereby the causes were related to system oversizing and high evapotranspiration in the area. As a consequence, the decrease in the abatement of water pollutants during the second year can be attributed to the creation of preferential water ?ow paths and short circuits through the constructed wetland (CW) bed. As a result of the oversizing of the CW, a theoretical resizing based on BOD5, TSS, TN or TP is proposed. The calculated values for the redesign were: 5.22 m2 considering DBO5, 0.18 m2 considering TSS, 10.14 m2 considering TN and 23.83 m2 considering TP. Considering the area where the HF-CW was located and in accordance with Spanish law for non-sensitive areas (no TN or TP requirements for wastewater discharge), BOD5 is the most appropriate parameter for design; it is 5.2 times lower than the HF-CW initially built and without risk of bed drying.

 Artículos similares

       
 
Karolina Migdal, Krzysztof Józwiakowski, Wojciech Czekala, Paulina Sliz, Jorge Manuel Rodrigues Tavares and Adelaide Almeida    
The objective of this study was to model the operation of a vertical-flow constructed wetland (VF-CW) for domestic wastewater, using Monte-Carlo simulations and selected probability distributions of various random variables. The analysis was based on col... ver más
Revista: Water

 
Pengzhang Li, Yun Wang, Yue Liu, Shuying Wang and Yongzhen Peng    
Previous studies have highlighted the salinization caused by the use of seawater to flush toilets and industrial wastewater entering the urban wastewater systems in coastal areas. Thus, in this study, the effect of salinity on N2O emissions during the pa... ver más
Revista: Water

 
Tahira Aslam, Safdar A. Mirza, Aneeba Rashid, Muhammad Arshad Javed and Luiza C. Campos    
The increasing human population continues to exert pressure on the freshwater scarcity. The availability of freshwater for crop irrigation has become challenging. The present study aimed to use domestic wastewater (DWW) for the irrigation of two rice cul... ver más
Revista: Water

 
Cristina E. Almeida-Naranjo, Elvia Gallegos, Elizabeth Domínguez, Paola Gutiérrez, Vladimir Valle, Alex Darío Aguilar, Alexis Debut and Catalina Vasco    
Oil palm empty fruit bunch fibers (OPEFBF), in three size ranges (small: 250?450 µm, medium: 450?600 µm, large: 600?800 µm), were investigated as a filter-bed material in biofilters for the removal of organic matter and nutrients. After saturation, these... ver más
Revista: Water

 
Yulia Frank, Alijon Khusanov, Mansur Yuldashov, Egor Vorobiev, Svetlana Rakhmatullina, Alexey Rednikin, Sherzodbek Tashbaev, Sarvinoz Mamatkarimova, Kristina Ruchkina, Sirojiddin Namozov, Laziz Turaev, Jobir Sobirov, Akramjon Yuldashev and Danil Vorobiev    
The objective of the study was a pre-screening of the microplastic (MP) content in surface water and benthic sediments of Kara Darya and Chirchiq rivers, the first-order tributaries of the Syr Darya River (Uzbekistan). For the first time, surface water a... ver más
Revista: Water