Resumen

This paper presents experimental results from a typical school building in Athens, equipped partly with a green roof system (GRS). Environmental monitoring took place in six classrooms located both under the concrete roof and the GRS sectors as well as in the immediate external environment during the warm and cold periods of a school year. Daily measurements of pollutants CO2, TVOCs (Total Volatile Organic Compound), PM1, PM2.5, and PM10 were performed in selected classes. Moreover, indoor ambient temperature (T) and relative humidity (RH) measurements were implemented in order to estimate the absolute humidity (AH) and assess the indoor environmental conditions. The results highlight that during summer, the GRS reduces temperature in a classroom on the top floor by about 2.8 °C, in comparison with the respective classroom under the concrete roof and that AH remained relatively stable for both classrooms. Amid winter, a reverse behavior occurs only for temperature. Moreover, air exchange rates (AER) were calculated by using the CO2 decay method for all of the classrooms. The results demonstrated insufficient ventilation for all experimental sights. Finally, concentrations of PM1, PM2.5 and PM10, were found to be relatively decreased, with average values of 0.79, 3.39, and 27.80 µg m-3. Levels of CO2 and TVOCs were elevated during class hours ranging from 469 to 779 ppm and from 6.63 ppm to 13.33 ppm, respectively, but generally within the respective limits of exposure. The examination of the indoor/outdoor (I/O) ratio of air pollutants, demonstrated that the outdoor meteorology affects only PM1 and PM2.5, as PM10 and TVOCs are strongly affected by internal sources and the activities of pupils.

 Artículos similares

       
 
ABDEL FATTAH A. QARAMAN, MAHER ELBAYOUMI, KHALID J. KHADOURA     Pág. Page:37 - 48Abstract
The indoor environmental quality (IEQ) in university buildings highly affect the health of students which they may experience a series of non-specific symptoms from being in that building. This paper aims to estimate the prevalence of sick building syndr... ver más

 
Sungroul Kim, Jungeun Lee, Sujung Park, Guillaume Rudasingwa, Sangwoon Lee, Sol Yu and Dae Hyun Lim    
Various studies have indicated that particulate matter <2.5 µm (PM2.5) could cause adverse health effects on pulmonary functions in susceptible groups, especially asthmatic children. Although the impact of ambient PM2.5 on children?s lower respiratory he... ver más

 
Nicholas Clements, Patricia Keady, Joanne B. Emerson, Noah Fierer and Shelly L. Miller    
Aerosol measurements were collected at fifteen homes over the course of one year in Colorado (USA) to understand the temporal variability of indoor air particulate matter and bacterial concentrations and their relationship with home characteristics, inha... ver más
Revista: Atmosphere

 
Ewa Bragoszewska, Anna Mainka, Józef S. Pastuszka, Katarzyna Lizonczyk and Yitages Getachew Desta    
The issue of healthy educational buildings is a global concern because children are particularly at risk of lung damage and infection caused by poor indoor air quality (IAQ). This article presents the results of a preliminary study of the concentration a... ver más
Revista: Atmosphere

 
Nuno Canha, Joana Lage, Catarina Galinha, Susana Coentro, Célia Alves and Susana Marta Almeida    
This study evaluated the emissions of specific indoor sources usually present in Portuguese dwellings in order to understand their impact on the indoor air quality. With this aim, three typical activities were studied including home heating using two typ... ver más