Redirigiendo al acceso original de articulo en 17 segundos...
Inicio  /  Applied Sciences  /  Vol: 14 Par: 7 (2024)  /  Artículo
ARTÍCULO
TITULO

Acoustic Emission Monitoring in Prestressed Concrete: A Comparative Study of Signal Attenuation from Wire Breaks and Rebound Hammer Impulses

Max Käding and Steffen Marx    

Resumen

Acoustic emission monitoring (AEM) has emerged as an effective technique for detecting wire breaks resulting from, e.g., stress corrosion cracking, and its application on prestressed concrete bridges is increasing. The success of this monitoring measure depends crucially on a carefully designed sensor layout. For this, the attenuation of elastic waves within the structure?s material is ideally determined in situ through object-related measurements (ORMs) with a reproducible signal source, typically a rebound hammer. This assumes that the attenuation coefficients derived from rebound hammer tests are comparable to those from wire breaks, thus allowing their results to be directly applied to wire break detection without further adjustments. This study challenges this assumption by analysing attenuation behaviour through an extensive dataset. Employing time-domain and frequency analysis, the research generates attenuation profiles from laboratory experiments and in situ measurements across various girders and bridge structures, extracting the slope and residual standard deviation (RSD). While generally validating this approach, the findings highlight differences in attenuation behaviour from among wire break signals and rebound hammer impulses, whereby the latter potentially underestimates the relevant attenuation of wire breaks by approximately 20%. Consequently, a transfer factor is proposed to adjust ORM results obtained with the rebound hammer for wire break scenarios. It consists of a scaling factor of 1.2 to modify the average attenuation coefficient and a constant term of ±1.0 dB/m to cover a 95% confidence interval, and thus, account for sample scattering. Moreover, the anisotropic attenuation behaviour across different structures was studied, showing that transverse attenuation consistently exceeds the longitudinal, significantly influenced by structural features such as voids. In prefabricated concrete bridges with in situ-cast concrete slabs, transverse signal transmission remains unhindered across multiple elements. Finally, the results provide a valuable reference for the design of sensor layouts in bridge monitoring, particularly benefiting scenarios where direct in situ experiences are lacking.

 Artículos similares

       
 
Vivian Schiller, Sandra Klaus, Ali Bilen and Gisela Lanza    
The complexity of products increases considerably, and key functions can often only be realized by using high-precision components. Microgears have a particularly complex geometry and thus the manufacturing requirements often reach technological limits. ... ver más
Revista: Algorithms

 
Eugen Stockburger, Hendrik Wester and Bernd-Arno Behrens    
Advanced high-strength steels (AHHS) are widely used in many production lines of car components. For efficient design of the forming processes, numerical methods are frequently applied in the automotive industry. To model the forming processes realistica... ver más
Revista: Applied Sciences

 
Yujing Jiang, Xinpeng Li, Changsheng Wang, Hengjie Luan, Sunhao Zhang, Gang Wang and Pu Wang    
Understanding the asperity damage behaviors of joints during shearing is critical for evaluating the stability of deep underground engineering structures. In this paper, we prepared plaster joints and used them for direct shear tests under different norm... ver más
Revista: Applied Sciences

 
Ci-Rong Huang and Ming-Chyuan Lu    
In the development of a tool wear monitoring system in milling, the complex cutting path always brings challenges to the system?s reliability in the production line. The cutting path effect on the acoustic emission (AE) and vibration signals during the m... ver más
Revista: Applied Sciences

 
Zhushuai Wang, Yu Yang, Yu Xu, Changhao Xin, Pengfei Liang and Ning Guo    
This paper presents two experimental schemes, graded cyclic loading and unloading, and variable lower limit cyclic loading and unloading, to investigate the energy evolution and acoustic emission characteristics of rocks under different cyclic loading an... ver más
Revista: Applied Sciences