Redirigiendo al acceso original de articulo en 23 segundos...
Inicio  /  Buildings  /  Vol: 13 Par: 7 (2023)  /  Artículo
ARTÍCULO
TITULO

Estimation of Durability of HC-550 Floor Slabs Based on Electrochemical Tests of Corrosion Rate of Reinforcement Strings in Concrete

Zofia Szweda and Dominik Czachura    

Resumen

The consequences of the loss of the load-bearing capacity due to the corrosion of prestressing steel can be much more dangerous than in the case of reinforced concrete structures, since failure can occur quite rapidly and without warning. A very important issue, therefore, is to determine the factors affecting the durability of prestressed structures exposed to aggressive agents, especially chloride ions. The aim of this study was to verify the protective properties of concrete of prefabricated HC-type prestressed concrete slabs in order to evaluate the possibility of their application in the ceilings of multilevel garages. In this paper, the corrosion rate of rebar steel in HC-550 floor slabs at a width of 1200 mm was estimated with nondestructive electrochemical methods: linear polarization and impedance spectroscopy. The general and mechanical properties of concrete prepared according to a formula in a laboratory and analogous concrete cut directly from the analyzed floor slabs were also studied. The porosity of concrete from these slabs was determined using X-ray-computed tomography for pore-related characterization. The values of the diffusion coefficient of chloride ions determined in previous works and the previously proposed model for the overexposure of the durability of floor slabs in chloride-containing environments were used to determine the durability of these slabs. Based on the empirical correlations adopted from the literature presenting the relationship of durability/adhesion over time and the corrosion parameters studied, a safe service life was determined at the nominal class of concrete equal to ?tcor.red = 30.48 years. In addition, in the case of discontinuities in the concrete structure, there may be a dangerous reduction in the time of corrosion initiation and a subsequent reduction in service life due to the loss of the adhesion of strut strands for up to 10.68 years of service life.

 Artículos similares

       
 
B. M. Tovt,E. M. Dzichkovskyy,O. E. Kryvchykov     Pág. 40 - 45
In this article the results of analytical and experimental research of the strained-and-stressed state of supporting structure of the track machine KRS-1 are presented. The analytical research is executed with the use of finiteelement method (FEM). The r... ver más

 
S. A. Kostrytsia,B. M. Tovt     Pág. 17 - 23
In the article the results of analytical and experimental studies of the stressed-and-strained state of load-bearing  elements of structure of ballast prism planner of SPZ-5/UA are presented. The analytical research is performed using the finite ele... ver más

 
D. I. Borodai     Pág. 43 - 48
The general problem of bridge reinforced concrete elements durability is formulated. The research problem is formulated. The model of estimation of bridge reinforced concrete elements resource on a design stage is offered. It enables us to predict the re... ver más

 
B. V. Savchynskyi     Pág. 229 - 231
The basic criteria of an estimation of reliability and durability of ferro-concrete road bridges are generalized. Recommendations for increase of reliability and durability of ferro-concrete road bridges are offered.