Review

Mechanical and Thermal Properties of Composite Precast Concrete Sandwich Panels: A Review

by
Herman Tawil
1,
Chee Ghuan Tan
1,*,
Nor Hafizah Ramli Sulong
2,
Fadzli Mohamed Nazri
3,
Muhammad M. Sherif
4 and
Ahmed El-Shafie
1
1
Department of Civil Engineering, Faculty of Engineering, Universiti Malaya, Kuala Lumpur 50603, Malaysia
2
School of Civil & Environmental Engineering, Faculty of Engineering, Queensland University of Technology, 2 George St, Brisbane, QLD 4000, Australia
3
School of Civil Engineering, Engineering Campus, Universiti Sains Malaysia, Gelugor 14300, Malaysia
4
Department of Civil, Construction and Environmental Engineering, School of Engineering, University of Alabama at Birmingham, Birmingham, AL 35205, USA
*
Author to whom correspondence should be addressed.
Buildings 2022, 12(9), 1429; https://doi.org/10.3390/buildings12091429
Submission received: 6 August 2022 / Revised: 28 August 2022 / Accepted: 6 September 2022 / Published: 11 September 2022

Abstract

:
Precast concrete sandwich panels (PCSPs) are utilized for the external cladding of structures (i.e., residential, and commercial) due to their high thermal efficiency and adequate composite action that resist applied loads. PCSPs are composed of an insulating layer with high thermal resistance that is mechanically connected to the concrete. In the recent decades, PCSPs have been a viable alternative for the fast deployment of structures due to the low fabrication and maintenance cost. Furthermore, the construction of light and thin concrete wythes that can transfer and resist shear loads has been achieved with the utilization of high-performance cementitious composites. As a result, engineers prefer PCSPs for building construction. PCSP design and use have been examined to guarantee that a building is energy efficient, has structural integrity, is sustainable, is comfortable, and is safe. Hence, this paper reviews the expanding knowledge regarding the current development of the mechanical and thermal properties of the PCSPs components; subsequently, future potential research directions are suggested.

1. Introduction

Insulated wall panels, also known as precast concrete sandwich panels (PCSPs) or integrally insulated wall panels, are being utilized extensively in structures and building envelope systems. The panels have superior thermal and acoustic insulation and load-bearing capacity [1]. The panels (wythes) are composed of rigid foam insulation sandwiched between two layers of concrete and held together using shear connectors (as illustrated in Figure 1) [2]. The panels can be prefabricated to ensure quality control, elimination of construction delays, and fast deployment [3]. The panels can be fabricated to consist of partial or complete composite action depending on the degree of shear force transmitted and the arrangement of shear connections [4]. Steel, fibre-reinforced polymers (FRPs), and plastics are the most common materials used for shear connectors [4]. However, steel shear connectors are preferred due to their mechanical properties. FRP connectors can provide both structural and thermal performance as they possess low heat conductivity [5]. On the other hand, plastic has a very poor thermal conductivity and consists of weak mechanical properties (i.e., low rigidity) limiting their use in panels [6,7].
In recent years, to enhance the stiffness of the concrete panels, basalt fibre-reinforced polymers (BFRPs) have been used as reinforcement and shear connectors [8,9,10]. BFRPs have similar strength and thermal conductivity to glass fibre-reinforced polymers (GFRPs) [11,12]. Moreover, BFRPs have a larger stiffness and are more durable than GFRPs [11,12,13]. Furthermore, BFRPs are easy to manufacture; they are also high thermal insulators that resist freezing and thawing environments [9,12]. In general, BFRPs have a manufacturing cost that is lower than that of carbon fibre-reinforced polymers but higher than that of GFRPs [9,11]. However, the long-term performance of BFRPs in rapid weathering and alkali environments has not been not fully investigated [14]. Researchers have illustrated that BFRPs have outperformed GFRPs and CFRPs in terms of thermal resistance and simplicity of production [15].
Woltman et al. (2013) illustrated that the panels have good thermal insulation; however, the efficiency is reduced over time [1]. The panels are often restricted to a minimum thickness of 51 mm due to cover and fire resistance requirements. Moreover, an efficient thermal insulation layer can have a thickness ranging between 51 mm and 102 mm [4]. The insulating layer is usually fabricated from extruded polystyrene (XPS) and expanded polystyrene (EPS). The XPS exhibits high shear strength when compared to EPS. This is due to the smoothness of EPS, which results in a low shear strength [4]. Moreover, EPS has a weak bond strength when subjected to freezing and thawing conditions due to their high moisture absorption rate [5].
Researchers are investigating the feasibility of reducing the thickness of PCSPs to save resources and materials and improve efficiency [14,15,16]. A crucial aspect in reducing the thickness of the panels is maintaining the thermal effectiveness and strength capacity of the cladding components [17]. Therefore, the utilization of partial/full-composite action alongside with anticorrosive reinforcement and shear connectors can be a feasible solution. Several researchers have concluded that a concrete layer with a minimum thickness of 80 mm is required to provide adequate cover for steel reinforcement in a typical concrete wythe [18]. Researchers found that two concrete panels could be attached together to provide composite action in resisting flexural loads [19]. This design mechanism resulted in enhancing the structural capacity while allowing for a small overall composite to be implemented [19]. However, the shear connectors need to be optimized to minimize the impact of thermal transfer (i.e., heat bypass) and structural rigidity [20]. Moreover, to reduce the overall thickness, a smaller cover needs to be implemented. In general, the concrete cover is specified based on the fabrication, transfer, and fire protection requirements and standards [20]. A minimum diameter and development length are required for the bolts used during the deployment of the panels (i.e., the assembling of the panels) [21]. On the other hand, fire protection is provided by the concrete cover in accordance with the design code [22,23]. It is worth noting that the cover requirement for non-structural cladding panels is less than those for structural cladding panels [24].
This review summarizes the expanding knowledge regarding the structural performance of precast concrete sandwich panels (PCSPs). Furthermore, the properties of the components of PCSPs consisting of the concrete wythes, insulation core, and mechanical connectors are discussed.

2. Sandwich Panels Behaviour

Sandwich panels made of precast and prestressed concrete are often utilised for various buildings’ outside and interior walls [24]. These panels may be quickly and easily mounted to any structural frame, including ones made of steel, reinforced concrete, pre-engineered metal, and precast or prestressed concrete [25]. The panels are prefabricated in a facility, brought to the project site, and erected by cranes. The panels reach vertically between foundations and floors or roofs to produce permanent walls but may also span horizontally between columns [26]. Sandwich panels are comparable to other precast or post-tensioned concrete members in design, detailing, manufacturing, handling, shipping, and erection [27]. On the other hand, due to an intervening layer of insulation, sandwich panels display behaviours and characteristics distinct from those of other precast or post-tensioned concrete members [28].
The panels can be classified as composite, partially composite, or non-composite. Composite panels are designed so that the two concrete wythes are fully bonded and work cooperatively to withstand the applied load. The usual failure behaviour of a composite panel is the crushing of concrete or the deterioration in steel reinforcement. It is worth noting that composite panels have shear connectors that are designed to withstand higher stresses than concrete or steel can resist. This is to minimize the possibility of a sudden failure in shear connectors. Figure 2 illustrates the linear stress distribution over the thickness of a sandwich panel that is (a) composite, (b) partially-composite, and (c) non-composite. Figure 2d displays the stress distribution of a single panel. A partially composite panel consists of connectors that can only transmit a percentage of the longitudinal shear. For partially composite panels, the failure occurs in the shear connectors.
The behaviour of the PCSPs is complex due to its material nonlinearity, the percentage composite action, and the interaction of the components. Researchers have developed models based on experimental results and a fundamental analytical approach. Moreover, the flexural behaviour of the PCSPs has been investigated to understand the effectiveness of the truss shear connectors to assure composite behaviour. However, there is a lack of experimental data due to the expenses associated with conducting full-scale testing and the difficulty associated with developing small-scale models. Furthermore, most manufacturers in North America and Europe do not share detailed information about the panel composition and design as they are protected under proprietary licenses [29].

3. Shear Connectors

Figure 3 illustrates the typical assembly of precast concrete sandwich panels consisting of two outer layers of concrete and a core insulative layer. The layers are bonded using shear connectors. The shear connectors act as a strong bridge between the outer and core layers [30]. The shear connectors should have an adequate diameter (a minimum of 4 mm is used) to improve the system’s overall structural integrity. It is critical to ensure that the panels can transfer the applied forces from one outer layer to the other outer layer without causing deterioration to the insulation core. Depending on the intended application and customer need, a shear connection design configuration (i.e., one-way, or two-way direction) and its orientation may vary.
Table 1 presents the various types of shear connectors that have been investigated. Zhang et al. [32] investigated the thermal performance of reinforced precast concrete sandwich panels with three different types of shear connections. Among the shear connectors that have been investigated were steel truss connectors, nominal thermo-mass connectors, and steel-pin connectors. The research illustrated that the nominal shear connectors have a low heat transfer rate and are the most stable under various loading situations. Moreover, truss shear connectors are comparable to the nominal shear connectors. It is worth noting that steel pin connectors do not provide sufficient composite behaviour [32].

4. PCSPs Insulation

PCSPs can be categorized as either bulk (i.e., mass) or reflective insulators. The mass insulation can reduce heat transfer by conduction, while reflective insulators reduce the heat transfer by radiation [39].

4.1. Mass Insulation

High thermal mass insulators absorb and retain heat by delaying the rate transfer through conduction. The use of external coatings with low thermal mass and conductivity for structures are helpful in isolating heat transfer in hot climates boosting the insulation efficiency. The efficacy of the mass insulators is dependent on the thickness of the material used and the heat conduction behaviour. Moreover, the effectiveness of the thermal insulator is dependent on the state of the subdivision and the density of the material [28]. Mass insulators are often composed of many small pockets filled with trapped air that significantly decrease the transmission of heat. Therefore, compressing mass insulators have a negative impact on their efficiency to insulate heat [39].

4.2. Reflective Insulation

A reflective (i.e., low emittance) surface provides thermal insulation by reflecting the heat radiation. This results in a reduction in the amount of heat transferred to a building due to solar rays and decreases the indoor temperature while improving the air quality within a structure. The effectiveness of a surface in emitting energy through thermal radiation is defined as emissivity. As the emissivity of a surface increases for a specific wavelength, the energy radiated at that wavelength also increases. Reflective insulators are composed of several low-emittance surfaces that entrap air. They are often employed in residential buildings such as attics, roofing, and wall systems [40,41]. Several researchers have examined the effects of reflective insulators on the thermal performance of the building envelopes [42,43,44,45].

5. Classification of Insulators

5.1. Classification Based on Form

The most prevalent forms of insulation include loose-fill spray foam, batts, blankets, and rigid boards. The structure, rehabilitation plan, and building code requirements must all be considered when choosing the insulation material [36,46]. Table 2 provides a summary of the performance characteristics of insulative materials based on their shape.

5.2. Classification Based on Composition

In general, the chemical and physical structure of a material determines the insulation properties. Papadopoulos [50] classified the insulation materials into organic, inorganic, mixed, and innovative technologies as illustrated in Figure 4.

5.2.1. Inorganic and Organic Insulators

Inorganic insulators are composed from non-renewable resources such as mineral wood, perlite, aerated concrete blocks, and foamy glass [51]. Organic insulators are composed of natural flora, wood wool, cellulose, expanded rubber, wood fibre, and sheep wool [52]. Organic insulators have numerous advantages such as being recyclable and nontoxic, along with other environmental benefits. Furthermore, the organic materials use less resources and energy for the manufacturing process compared to the inorganic insulators [53]. However, inorganic insulators are less expensive to utilize and have superior insulation properties [48]. Furthermore, inorganic insulators are resistant to fire and other chemicals compared to organic insulators.

5.2.2. Combined and Innovative Technologies

The utilization of several materials in insulators can improve the overall thermal performance and energy efficiency. Novel thermal insulators such as transparent insulative materials have been developed and have good thermal insulation and solar gathering properties [54]. Moreover, dynamic insulators that actively utilize ventilation systems have been employed to increase insulation efficiency [55]. Currently, insulators are composed of petrochemicals, fiberglass, mineral wool, polyurethane foam, and multiple foils [56]. Additionally, this material can be assembled in several configurations via simple installation techniques. However, these materials are non-renewable, generate waste, and depend on fossil fuels. Table 3 illustrates the material properties of the insulative materials that are currently being used. The selection of insulative material depends on the cost, durability, climatic factors, availability, mode of heat transmission, simplicity of installation, and structure orientation [14]. The following are examples of currently used insulative materials: (1) mineral wool, (2) cellulose, (3) expanded polystyrene (EPS) [57], cork, polyurethane (PUR) [58], extruded polystyrene (XPS) [57], and wood [59].

6. PCSPs Thermal Performance

Experimental characterization of conventional/typical PCSPs have revealed a thermal transmittance value (U-value) between 1.2 Wm−2 K−1 and 2.0 Wm−2 K−1 in panels with just 38 mm of expanded polystyrene (EPS) insulation core. Higher U-values have been observed with panels that consist of closely spaced connections, as thermal bridges are formed across the insulating layer. This results in increasing the number of heat loss pathways. More recently, Zhai et al. developed a PCSP with a novel nylon shear connector; the panel had an insulation core with a 100 mm thickness of polyurethane [60]. The panel had a U-value of 0.66 Wm−2 K−1. Zhai et al. also investigated the use of expanded polystyrene with the same configuration and had a U-value of 1.2 Wm−2 K−1 [60]. Based on the observed results, Zhai et al. concluded that the developed panels were more effective and cost efficient than PCSPs with fibre-reinforced polymer (FRP) connectors that have a U-value of 0.41 Wm−2 K−1 [60]. Keenehan et al. [61] observed that a PCSP with 120 mm of a phenolic foam (PF) insulative core had a U-value of 0.26 Wm−2 K−1 when using steel connectors and 0.15 Wm−2 K−1 when using fiberglass connectors. It is worth noting that the shear connectors were determined based on the mechanical and strength requirements. Woltman et al. [32] investigated panels with discrete 4-mm diameter steel connectors, which had a U-value of 0.36 Wm−2 K−1, while the panels with the same number of discrete 9.5mm diameter GFRP connectors and a 150 mm rigid XPS insulative core had a U-value of 0.34 Wm−2 K−1. Several researchers have illustrated that PCSPs with significant thicknesses ranging from 250 mm to 390 mm had a U-value less than 1.0 Wm−2 K−1 [61,62]. Panels with U-values that are much lower than those that have been investigated are necessary for residential and commercial buildings. In Ireland, the construction standard requires panels with a maximum of 0.21 Wm−2 K−1, and compliance incentives are given for an additional reduction in the U-value [63].
Vacuum insulation panels (VIPs) are lightweight, flexible and provide a viable solution for achieving thin PCSPs with high thermal resistance [63]. Currently, VIPs have low conductivity ratings compared to other commercially available insulative materials. VIPs are used to safeguard electronic equipment and are constructed of a hardcore using silica fume and covered with aluminium foil to provide an airtight wrap [64]. VIPs have been used for various applications [65]. In a recent publication, it was observed that the U-value was 0.007 Wm−2 K−1, which is three times lower than the U-value than common foam insulators [66]. VIPs are manufactured in predetermined module sizes to ensure their performance. VIPs that are custom designed have discontinuous layers of vacuum insulation between the two insulation layers. Although the incorporation of VIP into a PCSP is simple [18], there is a likelihood of delamination with the shear connectors (i.e., thermal bridging) [67].
Figure 5 shows the effects of overall panel thickness and insulation thickness on the ultimate load of the panel. In general, insulation thickness has a negative effect on the ultimate load of the panels, as a shorter shear-span between the loadings provides a higher capacity of the shear connector in PCSP.
Table 4 illustrates the research development that has occurred since 2007 in the area of PCSP in terms of alternative materials for wythes and composite shear connectors. The table presents the ultimate force applied in terms of the axial, bending, and shear characterization. Conventional concrete and steel panels have an ultimate load of 1450 kN, while foamed concrete has an ultimate load of 783 kN. Pantelides et al. observed a maximum bending load of 117.3 kN for PCSPs with GFRP shear connectors in conventional steel and concrete [26]. A maximum bending load of 22 kN to 45 kN was observed for similar PCSPs with glass fibre-reinforced plastic (GFRP) [26].

7. Future Development

According to this review, the vast majority of studies have focused on PCSP with heavy concrete materials. However, the impact of lightweight concrete on PCSP has not been investigated fully. Future research is necessary to develop low cost PCSPs with high thermal insulation and fire resistance. Furthermore, research should be conducted to achieve a high degree of adaptation (i.e., different geometry and sizes) and flexibility to install PCSPs. In addition, it is necessary to emphasize the mechanical strength and to evaluate the environmental impacts of the deployment of building insulators.

8. Conclusions

Initially, PCSPs were developed and manufactured as stressed-skin panels for structures. Rigid polystyrene foams, such as EPS or XPS, were used as the core material, while the outside layers of PCSP were constructed using concrete, plywood, and thin metal laminations (wythes). Concrete sandwich panels consist of two layers of structural concrete sandwiched between two layers of a low-strength and low-density insulative material. Horizontal mechanical shear connectors made of steel, carbon fibre-reinforced plastic, and glass fibre-reinforced plastic link the three layers. The design arrangement of shear connections affects the precast panels’ structural efficiency and capacity. The shear connectors and concrete wythes of a structure are typically reinforced with the same materials. The most challenging obstacle researchers must overcome is ensuring a secure connection between the wythes and the core material. PCSPs can be designed as non-composite, partially composite, or fully composite.
The mechanical and thermal behaviour of the sandwich panels depends on the material quality, quantity, diameter, spacing, and arrangement of the horizontal shear connections, the thermal concrete bridges, and the strength of the concrete wythes. Fully-composite panels are PCSPs that have achieved a full integration of strain and displacement compatibility. If a PCSP panel fails due to a shear connector before the concrete crushing and steel reinforcement yielding, then the panel cannot be considered a composite panel. Therefore, a prospective study on sandwich panels may investigate the following topics:
  • Development of PCSP samples using lightweight concrete suitable for use in both wall and flooring systems.
  • Enhancement of composite PCSP by providing more shear connectors in a smaller area while retaining optimum orientation and arrangement.
  • Investigation and development of PCSP specimens with alternative shapes of shear connectors that are functional for walls and floors.

Author Contributions

Conceptualization, C.G.T., F.M.N. and N.H.R.S.; methodology, C.G.T. and H.T.; formal analysis, C.G.T. and H.T.; investigation, H.T.; data curation, C.G.T. and H.T.; writing—original draft preparation, H.T.; writing—review and editing, C.G.T., N.H.R.S., M.M.S., F.M.N. and A.E.-S.; supervision, C.G.T. and N.H.R.S.; funding acquisition, M.M.S. and A.E.-S. All authors have read and agreed to the published version of the manuscript.

Funding

This work was supported by the Ministry of Higher Education under the Fundamental Research Grant Scheme (FRGS/1/2020/TK01/UM/02/2).

Data Availability Statement

The data are available upon request from the corresponding authors.

Acknowledgments

The Ministry of Higher Education supported this study under the Fundamental Research Grant Scheme (FRGS/1/2020/TK01/UM/02/2). The authors are grateful to the Public Service Department (JPA) for providing scholarships to perform this work.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Losch, E. Precast/Prestressed Concrete Sandwich Walls. Structure Magazine, April 2005; 16–20. [Google Scholar]
  2. Maximos, H.N.; Pong, W.A.; Tadros, M.K.; Martin, L.D. Behavior and Design of Composite Precast Prestressed Concrete Sandwich Panels with NU-Tie; University of Nebraska-Lincoln: Lincoln, NE, USA, 2007. [Google Scholar]
  3. PCI Committee on Pre-Cast Concrete Sandwich Wall Panels. PCI Committee Report: State-of-the Art of Precast/Prestressed Sandwich Wall Panels; Precast/Prestressed Concrete Institute: Chicago, IL, USA, 1997. [Google Scholar]
  4. Frankl, B.A.; Lucier, G.W.; Hassan, T.K.; Rizkalla, S.H. Behavior of precast, prestressed concrete sandwich wall panels reinforced with CFRP shear grid. PCI J. 2011, 56, 42–54. [Google Scholar] [CrossRef]
  5. Frankl, B.A. Structural Behavior of Insulated Precast Prestressed Concrete Sandwich Panels Reinforced with CFRP Grid. Concrete 2008, 243. [Google Scholar]
  6. Bai, F.; Davidson, J.S. Analysis of partially composite foam insulated concrete sandwich structures. Eng. Struct. 2015, 91, 197–209. [Google Scholar] [CrossRef]
  7. Brik, V. Advanced Concept Concrete Using Basalt Fiber/BF Composite Rebar Reinforcement; Transportation Research Board: Madison, WI, USA, 2003. [Google Scholar]
  8. Naito, C.; Hoemann, J.; Beacraft, M.; Bewick, B. Performance and Characterization of Shear Ties for Use in Insulated Precast Concrete Sandwich Wall Panels. J. Struct. Eng. 2012, 138, 52–61. [Google Scholar] [CrossRef]
  9. Brik, V. Basalt Fiber Composite Reinforcement for Concrete; Transportation Research Board: Madison, WI, USA, 1997. [Google Scholar]
  10. Sim, J.; Park, C.; Moon, D.Y. Characteristics of basalt fiber as a strengthening material for concrete structures. Compos. Part B Eng. 2005, 36, 504–512. [Google Scholar] [CrossRef]
  11. Liu, Q.; Shaw, M.T.; Parnas, R.S.; Mcdonnell, A. Investigation of basalt fiber composite mechanical properties for applications in transportation. Polym. Compos. 2006, 27, 41–48. [Google Scholar] [CrossRef]
  12. Hanswille, G.; Porsch, M.; Ustundag, C. Resistance of Headed Studs Subjected to Fatigue Loading Part I: Experimental Study. J. Constr. Steel Res. 2009, 65, 1954–1963. [Google Scholar] [CrossRef]
  13. Shi, J.W.; Zhu, H.; Wu, Z.S.; Wu, G. The Durability of BFRP and hybrid FRP sheets under freeze-thaw cycling. Adv. Mater. Res. 2011, 163, 3297–3300. [Google Scholar] [CrossRef]
  14. Mugahed Amran, Y.H.; Abang Ali, A.; Rashid, S.M.; Hejazi, F.; Safiee, N.A. Structural behavior of axially loaded precast foamed concrete sandwich panels. Constr. Build. Mater. 2016, 107, 307–320. [Google Scholar] [CrossRef]
  15. Hodicky, K.; Sopal, G.; Rizkalla, S.; Hulin, T.; Stang, H. Experimental and Numerical Investigation of the FRP Shear Mechanism for Concrete Sandwich Panels. J. Compos. Constr. 2015, 19, 04014083. [Google Scholar] [CrossRef]
  16. Voellinger, T.; Bassi, A.; Heitel, M. Facilitating the incorporation of VIP into precast concrete sandwich panels. Energy Build. 2014, 85, 666–671. [Google Scholar] [CrossRef]
  17. Bush, T.D.; Wu, Z. Flexural analysis of prestressed concrete sandwich panels with truss connectors. PCI J. 1998, 43, 76–83. [Google Scholar] [CrossRef]
  18. O’Hegarty, R.; Reilly, A.; West, R.; Kinnane, O. Thermal investigation of thin precast concrete sandwich panels. J. Build. Eng. 2020, 27, 100937. [Google Scholar] [CrossRef]
  19. Lee, B.J.; Pessiki, S. Thermal performance evaluation of precast concrete three-wythe sandwich wall panels. Energy Build. 2006, 38, 1006–1014. [Google Scholar] [CrossRef]
  20. EN 1992-1-2; Eurocode 2: Design of Concrete Structures—Part 1-2: General Rules—Structural Fire Design. European Committee for Standardization: Bruxelles, Belgium, 2004.
  21. Mugahed Amran, Y.H.; Rashid, R.S.M.; Hejazi, F.; Safiee, N.A.; Ali, A.A.A. Response of precast foamed concrete sandwich panels to flexural loading. J. Build. Eng. 2016, 7, 143–158. [Google Scholar] [CrossRef]
  22. Choi, I.; Kim, J.H.; You, Y.C. Effect of cyclic loading on composite behaviour of insulated concrete sandwich wall panels with GFRP shear connectors. Compos. Part B Eng. 2016, 96, 7–19. [Google Scholar] [CrossRef]
  23. Pantelides, P.; Surapaneni, R.; Reaveley, L.D. Structural performance of hybrid GFRP/steel concrete sandwich panels. J. Compos. Constr. 2008, 12, 570–576. [Google Scholar] [CrossRef]
  24. Xue, W.; Hu, X. State of the art of studies on precast concrete shear wall structures. J. Build. Struct. 2019, 40, 44–55. [Google Scholar] [CrossRef]
  25. Shirgaonkar, A.A.; Patil, Y.D.; Patil, H.S. Analytical study on new types of shear connectors in composite slab. IOP Conf. Ser. Mater. Sci. Eng. 2021, 1070, 012111. [Google Scholar] [CrossRef]
  26. Amin Einea, P.E.; Salmon, D.С.; Fogarasi, G.J.; Culp, T.D.; Tadros, M.K. State-of-the-Art of Precast Concrete Sandwich Panels. PCI J. 1991, 36, 78–98. [Google Scholar] [CrossRef]
  27. Metelli, G.; Bettini, N.; Plizzari, G. Experimental and numerical studies on the behaviour of concrete sandwich panels. Eur. J. Environ. Civ. Eng. 2011, 15, 1465–1481. [Google Scholar] [CrossRef]
  28. Liu, R.; Zhang, K.; Tao, M. Comparison study on thermal performance of the RC sandwich panels with different connectors. In Applied Mechanics and Materials; Trans Tech Publications Ltd.: Bäch, Switzerland, 2013. [Google Scholar] [CrossRef]
  29. Mugahed Amran, Y.H.; Rashid, R.S.M.; Hejazi, F.; Safiee, N.A.; Mohammed Bida, S. Structural Performance of Precast Foamed Concrete Sandwich Panel Subjected to Axial Load. KSCE J. Civ. Eng. 2018, 22, 1179–1192. [Google Scholar] [CrossRef]
  30. Choi, W.; Jang, S.J.; Do Yun, H. Design properties of insulated precast concrete sandwich panels with composite shear connectors. Compos. Part B Eng. 2019, 157, 36–42. [Google Scholar] [CrossRef]
  31. Rizkalla, S.; Hassan, T.; Lucier, G. FRP Shear Transfer Mechanism for Precast, Prestressed Concrete Sandwich Load-Bearing Panels. In Proceedings of the SP-265: Thomas T.C. Hsu Symposium: Shear and Torsion in Concrete Structures, New Orleans, LA, USA, 8–12 November 2009; p. 265. [Google Scholar]
  32. Pessiki, S.; Mlynarczyk, A. Experimental evaluation of the composite behavior of precast concrete sandwich wall panels. PCI J. 2003, 48, 54–71. [Google Scholar] [CrossRef]
  33. Hodicky, K.; Sopal, G.; Rizkalla, S.; Hulin, T.; Stang, H. FRP Shear Transfer Mechanism for Precast Concrete Sandwich Panels. Concr.-Innov. Des. Symp. Proc. 2015, 265, 477–478. [Google Scholar]
  34. Woltman, G.; Tomlinson, D.; Fam, A.; Greg, W.; Douglas, T.; Amir, F. Investigation of various GFRP shear connectors for insulated precast concrete sandwich wall panels. J. Compos. Constr. 2013, 17, 711–721. [Google Scholar] [CrossRef]
  35. Sustainability Victoria. Chapter 7: Insulation. In Energy Smart Housing Manual; Sustainability Victoria: Melbourne, VIC, Australia, 2010. [Google Scholar]
  36. Olathe, K. Reflective Insulation, Radiant Barriers and Radiation Control Coatings; Reflective Insulation Manufacturers Association International (RIMA-I): Phoenix, AZ, USA, 2002. [Google Scholar]
  37. Craven, C.; Garber-Slaght, R. Reflective Insulation in Cold Climates; Technical Report; Cold Climate Housing Research Center: Fairbanks, AK, USA, 2011. [Google Scholar]
  38. Saber, H.; Swinton, M.C. Determining through Numerical Modeling the Effective Thermal Existence of a Foundation Wall System with Low Emissivity Material and Furred. In Proceedings of the Airspace International Conference on Building Envelope Systems and Technologies, ICBEST 2010, Vancouver, BC, Canada, 27–30 June 2010; pp. 247–257. [Google Scholar]
  39. Saber, H.H.; Maref, W.; Swinton, M.C.; St-Onge, C. Thermal analysis of above-grade wall assembly with low emissivity materials and furred airspace. Build Environ. 2011, 46, 1403–1414. [Google Scholar] [CrossRef]
  40. Saber, H.; Maref, W.; Swinton, M. Numerical investigation of thermal response of basement wall systems with low emissivity material and furred airspace. In Proceedings of the 13th Canadian conference on Building Science and Technology, Winnipeg, MB, Canada, 10–13 May 2011. [Google Scholar]
  41. Saber, H.H.; Maref, W. Effect of furring orientation on thermal response of wall systems with low emissivity material and furred-airspace. In BEST 3: The Building Enclosure Science and Technology Conference Proceedings; National Research Council Canada: Ottawa, ON, Canada, 2012; pp. 1–15. [Google Scholar]
  42. Yüksel, N. The Review of Some Commonly Used Methods and Techniques to Measure the Thermal Conductivity of Insulation Materials. In Insulation Materials in Context of Sustainability; IntechOpen: London, UK, 2016. [Google Scholar] [CrossRef]
  43. Aditya, L.; Mahlia, T.M.I.; Rismanchi, B.; Ng, H.M.; Hasan, M.H.; Metselaar, H.S.C.; Muraza, O.; Aditiya, H.B. A review on insulation materials for energy conservation in buildings. Renew. Sustain. Energy Rev. 2017, 73, 1352–1365. [Google Scholar] [CrossRef]
  44. Al-Homoud, M.S. Performance characteristics and practical applications of common building thermal insulation materials. Build. Environ. 2005, 40, 353–366. [Google Scholar] [CrossRef]
  45. Jacqueline, A.S.; Ting, D.S.-K. Engineering for Sustainable Development and Living: Preserving a Future for the Next Generation to Cheris; Brown Walker Press: Boca Raton, FL, USA, 2021. [Google Scholar]
  46. Papadopoulos, A.M. State of The Art in Thermal Insulation Materials and Aims for Future Developments. Energy Build. J. 2005, 37, 77–86. [Google Scholar] [CrossRef]
  47. Sadeghinezhad, E.; Mehrali, M.; Saidur, R.; Mehrali, M.; Latibari, S.T.; Akhiani, A.R.; Metselaar, H.S.C. A comprehensive review on graphene nanofluids: Recent research, development and applications. Energy Convers. Manag. 2016, 111, 466–487. [Google Scholar] [CrossRef]
  48. Abdul Rahim, N.H.; Mohamad, N.; Abdul Samad, A.A.; Goh, W.I.; Jamaluddin, N. Flexural Behaviour of Precast Aerated Concrete Panel (PACP) with Added Fibrous Material: An Overview. MATEC Web Conf. 2017, 103, 02005. [Google Scholar] [CrossRef]
  49. Wong, L.; Eames, P.C.; Perera, R.S. A review of transparent insulation systems and the evaluation of payback period for building applications. Sol. Energy 2007, 81, 1058–1071. [Google Scholar] [CrossRef]
  50. Gan, G. Numerical Evaluation of Thermal Comfort in Rooms with Dynamic Insulation. Build Environ. 2000, 35, 445–453. [Google Scholar] [CrossRef]
  51. Memon, S.A. Phase change materials integrated in building wall: A state of the art review. Renew. Sustain. Energy Rev. 2014, 31, 870–906. [Google Scholar] [CrossRef]
  52. Takigami, H.; Watanabe, M.; Kajiwara, N. Destruction behavior of hexabromocyclododecanes during incineration of solid waste containing expanded and extruded polystyrene insulation foams. Chemosphere 2014, 116, 24–33. [Google Scholar] [CrossRef] [PubMed]
  53. Avar, G.; Meier-Westhues, U.; Casselmann, H.; Achten, D. Polyurethanes A2. In Polymer Science: A Comprehensive Reference; Elsevier: Amsterdam, The Netherlands, 2012; p. 411. [Google Scholar]
  54. Limam, A.; Zerizer, A.; Quenard, D.; Sallee, H.; Chenak, A. Experimental thermal characterization of bio-based materials (Aleppo Pine wood, cork and their composites) for building insulation. Energy Build. 2016, 116, 89–95. [Google Scholar] [CrossRef]
  55. Woltman, G.D.; Hanna, M.; Tomlinson, D.; Fam, A. Thermal Insulation EffecMtiveness of Sandwich Concrete Walls with GFRP Shear Connectors for Sustainable Construction. In Proceedings of the 4th International Conference on Durability and Sustainability of FRP Composite for Construction and Rehabilitation, Quebec, QC, Canada, 20–22 July 2011; pp. 425–432. [Google Scholar]
  56. Yang, J.L.; Xue, W.C. State-of-art of fiber reinforced plastic connectors. In precast concrete sandwich wall panels. Low Temp Arch. Technol. 2012, 8, 139–142. [Google Scholar]
  57. Keenehan, J.; Concannon, K.; Hajializadeh, D.; McNally, C. Numerical Assessment of The Thermal Performance of Structural Precast Panels; University College of Dublin: Dublin, Ireland, 2012. [Google Scholar]
  58. Zhai, X.; Wang, Y.; Wang, X. Thermal performance of precast concrete sandwich walls with a novel hybrid connector. Energy Build. 2018, 166, 109–121. [Google Scholar] [CrossRef]
  59. Ferreira, R.; Pereira, D.; Gago, A.; Proença, J. Experimental Characterization of Cork Agglomerate Core Sandwich Panels for Wall Assemblies in Buildings. J. Build. Eng. 2016, 5, 194–210. [Google Scholar] [CrossRef]
  60. Baetens, R.; Jelle, B.P.; Thue, J.V.; Tenpierik, M.J.; Grynning, S.; Uvsløkk, S. Vacuum Insulation Panels for Building Applications: A Review and Beyond. Energy Build. 2010, 42, 147–172. [Google Scholar] [CrossRef] [Green Version]
  61. Hülsmeier, F. Vakutex-vacuum-insulated textile concrete facade elements. In Proceedings of the Annual International Conference on Architecture and Civil Engineering (ACE 2014), Singapore, 24–25 March 2014; Global Science and Technology Forum: Singapore, 2014; pp. 235–241. [Google Scholar]
  62. Kingspan. Optim-R Vacuum Insulation—Next Generation Insulation Solution for External Masonry Walls; Kingspan: Kingscourt, UK, 2018. [Google Scholar]
  63. Tenpierik, J.; Cauberg, J.J.M. Encapsulated vacuum insulation panels: Theoretical thermal optimization. Build. Res. Inf. 2010, 38, 660–669. [Google Scholar] [CrossRef]
  64. Shin, D.H.; Kim, H.J. Composite effects of shear connectors used for lightweight-foamed-concrete sandwich wall panels. J. Build. Eng. 2020, 29, 101108. [Google Scholar] [CrossRef]
  65. Hee Kang, W.; Kim, J.H. Reliability-Based Flexural Design Models for Concrete Sandwich Wall Panels with Continuous GFRP Shear Connectors. Compos. Part B Eng. 2016, 89, 340–351. [Google Scholar] [CrossRef]
  66. Mohamad, N.; Muhammad, H.M. Testing-of-precast-lightweight-foamed-concrete-sandwich-panel-with-single-and-double-symmetrical-shear-truss-connectors-under-eccentric-loading. Adv. Mater. Res. 2011, 335–336, 1107–1116. [Google Scholar] [CrossRef]
  67. Flores-Johnson, E.A.; Li, Q.M. Structural behaviour of composite sandwich panels with plain and fibre-reinforced foamed concrete cores and corrugated steel faces. Compos. Struct. 2012, 94, 1555–1563. [Google Scholar] [CrossRef]
  68. Joseph, J.D.R.; Prabakar, J.; Alagusundaramoorthy, P. Experimental studies on through-thickness shear behavior of EPS based precast concrete sandwich panels with truss shear connectors. Compos. Part B Eng. 2019, 166, 446–456. [Google Scholar] [CrossRef]
  69. Hetao, H.; Kefan, J.; Wenhao, W.; Bing, Q.; Mingji, F.; Canxing, Q. Flexural Behavior of Precast Insulated Sandwich Wall Panels: Full-scale Tests and Design Implications. Eng. Struct. 2019, 180, 750–761. [Google Scholar] [CrossRef]
  70. Gara, F.; Ragni, L.; Roia, D.; Dezi, L. Experimental Tests and Numerical Modelling of Wall Sandwich Panels. Eng. Struct. 2012, 37, 193–204. [Google Scholar] [CrossRef]
  71. Benayoune, A.; Abdul Samad, A.; Abang Ali, A.; Trikha, D.N. Response of pre-cast reinforced composite sandwich panels to axial loading. Constr. Build. Mater. 2007, 21, 677–685. [Google Scholar] [CrossRef]
  72. Benayoune, A.; Abdul Samad, A.A.; Trikha, D.N.; Abang Ali, A.A.; Ashrabov, A.A. Structural behaviour of eccentrically loaded precast sandwich panels. Constr. Build. Mater. 2006, 20, 713–724. [Google Scholar] [CrossRef]
  73. Kim, J.H.; Chan You, Y. Composite behavior of a novel insulated concrete sandwich wall panel reinforced with GFRP shear grids: Effects of insulation types. Materials 2015, 8, 899–913. [Google Scholar] [CrossRef] [PubMed]
  74. Tomlinson, D.; Fam, A. Flexural behavior of precast concrete sandwich wall panels with basalt FRP and steel reinforcement. PCI J. 2015, 60, 51–71. [Google Scholar] [CrossRef]
  75. Tomlinson, D.; Fam, A. Experimental investigation of precast concrete insulated sandwich panels with glass fiber-reinforced polymer shear connectors. ACI Struct. J. 2014, 111, 595–605. [Google Scholar] [CrossRef]
  76. Henin, E.; Morcous, G.; Tadros, M.K. Precast/Prestressed Concrete Sandwich Panels for Thermally Efficient Floor/Roof Applications. Pract. Period. Struct. Des. Constr. 2014, 19, 04014013. [Google Scholar] [CrossRef]
  77. Lee, J.; Pessiki, S. Experimental evaluation of precast, prestressed concrete, three-wythe sandwich wall panels. PCI J. 2008, 53, 95–115. [Google Scholar] [CrossRef]
  78. Benayoune, A.; Abdul Samad, A.A.; Trikha, D.N.; Abang Ali, A.A.; Ellinna, S.H.M. Flexural behavior of pre-cast concrete sandwich composite panel—Experimental and theoretical investigations. Constr. Build. Mater. 2008, 22, 580–592. [Google Scholar] [CrossRef]
  79. Bush, T.D.; Stine, G.L. Flexural Behavior of Composite Precast Concrete Sandwich Panels With Continuous Truss Connectors. PCI J. 1994, 39, 112–121. [Google Scholar] [CrossRef]
  80. Lee, A.J.; Pessiki, S. Design and analysis of precast, prestressed concrete, three-wythe sandwich wall panels. PCI J. 2007, 52, 70–83. [Google Scholar] [CrossRef]
  81. Hodicky, K.; Hulin, T.; Schmidt, J.W.; Stang, H. Structural Performance of New Thin-Walled Concrete Sandwich Panel System Reinforced with BFRP Shear Connectors. In Proceedings of the 4th Asia-Pacific Conference on FRP in Structures, Melbourne, VIC, Australia, 11–13 December 2013. [Google Scholar]
  82. Shams, A.; Horstmann, M.; Hegger, J. Experimental investigations on Textile Reinforced Concrete (TRC) sandwich sections. Compos. Struct. 2014, 118, 643–653. [Google Scholar] [CrossRef]
Figure 1. A precast concrete sandwich panel: (a) rear view, (b) shear connector (edited from [6,7]).
Figure 1. A precast concrete sandwich panel: (a) rear view, (b) shear connector (edited from [6,7]).
Buildings 12 01429 g001
Figure 2. Strain distribution of precast composite sandwich panels [29].
Figure 2. Strain distribution of precast composite sandwich panels [29].
Buildings 12 01429 g002
Figure 3. Typical drawing of a precast sandwich panel using a wire mesh as a shear connector [31].
Figure 3. Typical drawing of a precast sandwich panel using a wire mesh as a shear connector [31].
Buildings 12 01429 g003
Figure 4. Classification of the commonly used insulative materials [50].
Figure 4. Classification of the commonly used insulative materials [50].
Buildings 12 01429 g004
Figure 5. Ultimate load vs. overall thickness of panel with different wythe materials.
Figure 5. Ultimate load vs. overall thickness of panel with different wythe materials.
Buildings 12 01429 g005
Table 1. Typical design of shear connectors and materials used.
Table 1. Typical design of shear connectors and materials used.
StudyConnection Material/TypeDesignInsulative MaterialsThickness (mm)
[33]Steel Truss-Shaped Shear ConnectorBuildings 12 01429 i001XPS6
[34]CFRPBuildings 12 01429 i002XPS, EPS50, 100, 150
[35]Lattice Fiberglass Polymer Tie-Connector: FRPBuildings 12 01429 i003XPS, EPS75
[27]Diagonal AnchorBuildings 12 01429 i004 6
[36]Steel M-TieBuildings 12 01429 i005XPS50
[37]MC Welded Wire Girder ConnectorBuildings 12 01429 i006XPS, EPS75
[38]GFRPBuildings 12 01429 i007EPS100
[9]PinBuildings 12 01429 i008Foam50
[34]FRP: NU-TieBuildings 12 01429 i009XPS75, 150
Table 2. Performance characteristics for common insulators [47,48,49].
Table 2. Performance characteristics for common insulators [47,48,49].
FormMaterialDensity (kg/m3)Thermal
Conductivity (W/m−2K−1)
Maximum Service Temp. (°C)Durability
Blankets: Batts or RollsFiberglass (Sand and Recycled Glass)12–560.04–0.033−4–260Compression Reduces R-Value
Rockwool (Natural Rocks)40–2000.037−240–800Compression Reduces R-Value
Polyethylene35–400.041−40–90R-Value Decreases with Time
Loose-Fill Blown-in or Poured-inOpen Cell Structure10–480.038–0.030−4–260Compression and Moisture Degrade R-Value
Rockwool (Open Cell Structure)24-360.040−240–800Compression and Moisture Degrade R-Value
Cellulose (Ground-up Wastepaper)24–360.054–0.04680Compression and Moisture Degrade R-Value
Perlite (Natural Glassy Volcanic Rock)32–1760.06–0.04760Good
Vermiculite64–1300.068–0.0631315Good
Rigid BoardFiberglass (Open Cell Structure)24–1120.035–0.032−4–350More Rigid Than Batts
Expanded Polystyrene (Closed Cell Foam)16–350.038–0.037100R-Value Decreases with Time
Extruded Polystyrene (Closed Cell Foam)26–350.032–0.030100R-Value Decreases with Time
Table 3. Physical properties of the commonly used insulative materials [31,46].
Table 3. Physical properties of the commonly used insulative materials [31,46].
Physical PropertyPolystyrenePolyurethane
EPSXPSUnfacedFaced
Density (kg/m3)11.2–14.417.6–22.428.820.8–25.628.8–35.24832–9632–96
Water Absorption (%)<4.0<3.0<2.0<0.3<3.01.0–2.0
Compressive Strength (kPa)35–7090–103172103–172276–414690110–345110
Tensile Strength (kPa)124–172172345724310–965348
Linear Coef. of Expansion 10−6 mm/mm/C45–7254–10854–108
Shear Strength (kPa)138–241-241482138–690138–690
Flexural Strength (kPa)69–172207–276345276–345414–517695345–1448276–345
Thermal Conductivity Wm/m2/C0.0430.0370.0330.0290.0260.014–0.022
Maximum Temperature °C71118
Table 4. Summary of previous research conducted on PCSPs.
Table 4. Summary of previous research conducted on PCSPs.
StudyWythe MaterialShear Connector
Type
Shear Connector ShapesInsulative MaterialsComposite ActionUltimate Load (kN)Insulation Core Thickness (mm)# of LayersLoading TypeStructural SystemOverall Thickness (mm)
[68]Lightweight ConcreteSteel BarNon-ContinuousMineral Hydrated Foamed MaterialFull17.8 to 34.9150-Static Wind and AxialWall350
[21] Lightweight ConcreteSteel TrussContinuousEPSFull 31.4 to 47.130SingleAxial Wall150
[69]Lightweight ConcreteSteel TrussContinuousEPSFull250 to 60040SingleAxialWall125
[70]Lightweight ConcreteSteel Truss (6-mm)ContinuousEPSFull188 to 355-DoubleAxialWall-
[71]Lightweight ConcreteSteel-Encased Concrete 18 to 44 FlexuralSlab-
[20]Lightweight ConcreteCFRP GridContinuousPhenolic FoamPartial 90 ThermalWall150
[72]Normal ConcreteSteel TrussContinuousEPSFull20.04 to 26.00100SingleAxialWall150
[73]Normal ConcreteSteel BarNon-ContinuousEPSFull-100-AxialWall150
[74]Normal ConcreteSteel TrussContinuousEPSFull401 to 78380SingleAxial and FlexuralWall150
[75]Normal ConcreteSteel TrussContinuousPolystyrene FoamFull1250 to 145030SingleAxialWall130
[76]Normal ConcreteSteel TrussContinuousEPSFull105030SingleAxialWall130
[69]Normal
Concrete
GFRP BarContinuousEPS, XPS and VIPFull 100 FlexuralWall220
[77]Normal ConcreteGFRP Shear GridContinuousEPS and XPS FoamFull23 to 75100SingleFlexuralWall220
[78]Normal ConcreteBFRP BarNon-ContinuousEPSPartial38 to 41100 FlexuralWall270
[79]Normal ConcreteGFRP StudNon-ContinuousRigid FoamPartial17 to 95100 FlexuralWall270
[80]Normal ConcreteGFRP TrussContinuousXPS 44 to 90102SingleFlexuralSlab and Roof164
[4]Normal ConcreteGFRP-GridContinuousXPS and EPSFull45 to 90102SingleFlexuralWall203
[26]Normal ConcreteGFRP ShellContinuousEPSFull25 to 4576SingleFlexuralWall and Slab200
[81]Normal ConcreteSteel M-TieNon-Continuous Partial30 to 3650 FlexuralWall203
[81]Normal ConcreteSteel TrussContinuousPolystyreneFull117.340SingleFlexuralWall120
[79]Normal ConcreteSteel TrussContinuousEPSFull14 to 2150SingleFlexuralWall200
[79]Normal Concrete (Three Layers)Steel 25 to 50 FlexuralWall200
[80]High-Performance ConcreteBFRP and CFRP GridContinuousEPS, Kingspan Free Rigid PhenolicPartial12 to 14290SingleFlexuralBeam350
[82]Textile-Reinforced ConcretePin ConnectorNon-ContinuousPolymeric Rigid FoamFull 160 Flexural-280
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Tawil, H.; Tan, C.G.; Sulong, N.H.R.; Nazri, F.M.; Sherif, M.M.; El-Shafie, A. Mechanical and Thermal Properties of Composite Precast Concrete Sandwich Panels: A Review. Buildings 2022, 12, 1429. https://doi.org/10.3390/buildings12091429

AMA Style

Tawil H, Tan CG, Sulong NHR, Nazri FM, Sherif MM, El-Shafie A. Mechanical and Thermal Properties of Composite Precast Concrete Sandwich Panels: A Review. Buildings. 2022; 12(9):1429. https://doi.org/10.3390/buildings12091429

Chicago/Turabian Style

Tawil, Herman, Chee Ghuan Tan, Nor Hafizah Ramli Sulong, Fadzli Mohamed Nazri, Muhammad M. Sherif, and Ahmed El-Shafie. 2022. "Mechanical and Thermal Properties of Composite Precast Concrete Sandwich Panels: A Review" Buildings 12, no. 9: 1429. https://doi.org/10.3390/buildings12091429

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.