Redirigiendo al acceso original de articulo en 18 segundos...
Inicio  /  Buildings  /  Vol: 13 Par: 9 (2023)  /  Artículo
ARTÍCULO
TITULO

A Study on Mechanical Performance of an Innovative Modular Steel Building Connection with Cross-Shaped Plug-In Connector

Hongwei Ma    
Ziming Huang    
Xiongbin Song and Yuhong Ling    

Resumen

Modular steel buildings show high assembly degree and fast installation speed. The inter-module connection (IMC) is one of the key technologies that restrict the robustness of modular steel buildings. An innovative IMC with a cross-shaped plug-in connector is proposed, and the connection consists of end plates of columns, the cross-shaped plug-in connector, bolts, cover plates, and one-side bolts. The proposed IMC is easily constructed, and the cross-shaped plug-in connector can improve the shear resistance of the core area. The mechanical model of the proposed IMC is presented, and the panel zone volume modified factor and initial rotational stiffness modified factor are proposed for calculating the shear capacity of the panel zone and the initial rotational stiffness. Numerical simulation was conducted considering the influences of axial compression ratios, sections of beams and columns, and the thickness of the tenon plate of the connector. The bearing capacity of the proposed IMC was analyzed, and the values of the two factors mentioned above were calculated, and their regression formulas are presented. The results show that the sections of beams and columns and the axial compression ratios show great influences on the bearing capacity of the proposed IMC, while the thickness of the tenon of the cross-shaped plug-in connector shows almost no effect. In addition, the sections of beams and columns show great influences on the shear capacity of the panel zone, as well as the initial rotational stiffness of the proposed IMC, while the thickness of the tenon of the cross-shaped plug-in connector and the axial compression ratios show little effect and almost no effect, respectively. Furthermore, the bending moment limit of the beam end of the proposed IMC is suggested to be 0.6 times the resistance bending moment, and the proposed IMC is considered to be a rigid connection or inclined to a rigid connection The proposed IMC has good mechanical performance, and design recommendations are presented.

 Artículos similares

       
 
Xuhui He, Zhiyu Wang, Chao Li, Ce Gao, Yongfeng Liu, Changpeng Li and Bin Liu    
This paper presents an experimental study on the box girder of a low-tower cable-stayed railway bridge with a W-shaped section that consists of prestressed concrete diagonal braces. A 1:6 scale test model was designed and constructed for the experiment. ... ver más
Revista: Buildings

 
Hongjun Li, Baoyun Zhao, Zhengjun Hou and Hongyao Min    
The foundations of bridges and other tall buildings are often subjected to cyclic loads. Therefore, it is essential to investigate the mechanical properties of rock?concrete composite foundations under cyclic loads. In this paper, uniaxial cyclic loading... ver más
Revista: Buildings

 
Chang Li, Shuren Hao, Shengjie Zhang, Yongqing Jiang and Zhidong Yi    
In order to understand the long-term process of CO2 storage and demonstrate its safety, multi-field coupled numerical simulation is considered a crucial technology in the field of geological CO2 storage. This study establishes a site-specific homogeneous... ver más
Revista: Water

 
Jing Liu, Tao Zhang, Zhicheng Pan and Fanjun Ma    
Concrete-filled round-ended steel tubes (CFRTs) are a unique type of composite stub columns, which have the advantage of aesthetics and a well-distributed major?minor axis. Thus, the structure has been widely employed as piers and columns in bridges. To ... ver más
Revista: Buildings

 
Yingwei Liang, Assaad Taoum, Nathan Kotlarewski, Andrew Chan and Damien Holloway    
The mechanical properties of fibre-managed Eucalyptus nitens (E. nitens) cross-laminated timber (CLT) have previously been extensively studied, proving the material to be structurally safe and reliable. However, the vibration performance of CLT manufactu... ver más
Revista: Buildings