Redirigiendo al acceso original de articulo en 15 segundos...
Inicio  /  Buildings  /  Vol: 13 Par: 12 (2023)  /  Artículo
ARTÍCULO
TITULO

Study of Heat Recovery Equipment for Building Applications

Lelia Letitia Popescu    
Razvan Stefan Popescu and Tiberiu Catalina    

Resumen

Nowadays, heat exchangers find widespread use across various applications in different fields, particularly in the field of heat recovery. This paper provides a detailed explanation of a plate heat exchanger counter-flow model developed in Simulink/Matlab. Water was employed in simulations for both circuits, although the thermal properties of other fluids can be investigated by modifying them. The ?Tanks in series? method was used for simulation purposes. The developed model enables users to explore the impact of various parameters on heat exchanger functionality, such as altering the number of plates, the material or thickness of the plates, and the nature of thermal agents (gaseous or liquid). These models play a crucial role not only in simulating and sizing heat exchangers but also in achieving parametric optimization. Parameter variations can be employed to examine the operation of existing equipment under conditions different from their design specifications. The Simulink/Matlab proposed model, featuring a variable number of finite volumes to ensure high accuracy, was compared to the classical design method for plate heat exchangers. The results revealed good accuracy, with relative errors for heat transfer rate remaining below 2.6%. This research also considered the study of the number of finite volumes necessary for achieving accurate results. For the 40 finite volumes model, the relative error for heat transfer rate is less than 10%. Dividing the mesh into 50 finite volumes along the fluid flow direction resulted in relative errors ranging from 1.6% to 1.7%, indicating that a finer mesh was not necessary. To validate the conceived model, experimental data from the literature were compared. The relative errors for heat transfer rate between the Matlab/Simulink model?s results and experimental data ranged from 1.58% to 11.92%, demonstrating a strong agreement between the conceived model and the experimental values.

 Artículos similares

       
 
Barbara Cardone, Ferdinando Di Martino and Vittorio Miraglia    
The application of sentiment analysis approaches to information flows extracted from the social networks connected to particular critical periods generated by pandemic, climatic and extreme environmental phenomena allow the decision maker to detect the e... ver más
Revista: Urban Science

 
Ling Zhou, Peng Yan, Yanjun Zhang, Honglei Lei, Shuren Hao, Yueqiang Ma and Shaoyou Sun    
The optimization of the production scheme for enhanced geothermal systems (EGS) in geothermal fields is crucial for enhancing heat production efficiency and prolonging the lifespan of thermal reservoirs. In this study, the 4100?4300 m granite diorite str... ver más
Revista: Water

 
Yeng-Fong Shih, Chun-Wei Chang, Teng-Hsiang Hsu and Wei-Yi Dai    
Wood?plastic composites (WPCs), abbreviated as WPCs, are typically composite materials made by mixing wood flour and thermoplastic resins, and then shaped through processes such as extrusion or compression. They have emerged as a viable and advanced alte... ver más
Revista: Buildings

 
Elisabeth Fassbender, Josef Rott and Claudia Hemmerle    
Cities face the consequences of climate change, specifically the urban heat island (UHI) effect, which detrimentally affects human health. In this regard, deploying PV modules in urban locales prompts inquiry into the impact of energy-active building com... ver más
Revista: Buildings

 
Zhe Wang, Weisheng Xu, Qing Xu, Yangming Wang and Yingna Zhu    
To investigate the mechanism of reinforcing soft soil with cement-mixing pile, based on ABAQUS secondary development, a numerical simulation study of the hydration reaction of cement-mixing piles was conducted. In this study, the influence of ground temp... ver más
Revista: Buildings