Redirigiendo al acceso original de articulo en 18 segundos...
ARTÍCULO
TITULO

Bridge Structures Cracks ? What Made that Phenomena so Common?

Krzysztof Germaniuk    
Tomasz Gajda    
Artur Sakowski    
Tomasz Wierzbicki    
Przemyslaw Kaminski    

Resumen

The common phenomena ? cracks appearance on newly built reinforced concrete bridge structures - is being detected in Poland for several years now. That phenomena is regarded as threatening in case of bridge structures, despite the fact that reinforced concrete theory considers cracks as a standard concrete performance. Cracks are very likely to appear on concrete surface. Cracks are usually detected during concrete surface treatment before protective coating laying. Cracks appear on monolith structures, mainly at the slab spans and foreheads as well as, at support columns in a minor range. Concrete surface cracks openings reach up to 2 mm size. The experience gained throughout consulting works on cracked structures are discussed in that paper. The influence of concrete surface mechanical cleaning prior the protective coatings laying on the crack ?visual? intensification was also discussed herein. Crack openings measurement rules, as well as the most common mistakes made during the crack measurements and their real value assessment were described in the paper. The maximal crack opening allowances fluctuations in Polish and European concrete Codes were also discussed here. It was proved that the spotted crack opening increase is caused by the codes changes and by bold reinforcing cover. The bold cover is regarded as the corrosion protection of reinforcing bars. The cover bold and crack opening allowance dependency was discussed in the paper. The effect of Euro codes and the Minister of Transport and Maritime Economy Ordnance from May 30th 2000 titled ?Technical requirements for highway engineering structures and their locations? simultaneous obligation on reinforced concrete structures cracks assessment was deliberated. At the conclusion the necessary modifications in crack assessment practice were claimed. The cracks should be assessed on the basis of homogenous code system. Their openings are dependent straight forward from the reinforcement cover thickness. One should avoid crack measurement at the sections, at which the crack edges are mechanically shattered. The crack opening assessment should be dependent on cover thickness. The rod anti shrinkage activity reaches the cover depth approximately to the depth equal to the rod diameter only. That fact should be taken under consideration during crack assessment.

 Artículos similares

       
 
Iurii Vakaliuk, Silke Scheerer and Manfred Curbach    
In the case of solid slabs made from reinforced concrete that are usually subjected to bending, large areas of the structure are stressed well below their load-bearing capacity or remain stress-free. Contrary to this are shell structures, which can bridg... ver más
Revista: Applied Sciences

 
Massimiliano Pepe, Domenica Costantino and Vincenzo Saverio Alfio    
The aim of the paper is to identify a suitable method for assessing the deformation of structures (buildings, bridges, walls, etc.) by means of topographic measurements of significant targets positioned on the infrastructure under consideration. In parti... ver más
Revista: Infrastructures

 
Philipp Spelten, Morten-Christian Meyer, Anna Wagner, Klaus Wolf and Dirk Reith    
Integrating physical simulation data into data ecosystems challenges the compatibility and interoperability of data management tools. Semantic web technologies and relational databases mostly use other data types, such as measurement or manufacturing des... ver más
Revista: Information

 
F. Necati Catbas, Jacob Anthony Cano, Furkan Luleci, Lori C. Walters and Robert Michlowitz    
This study investigates the capture of digital data and the development of models for structures with incomplete documentation and plans. LiDAR technology is utilized to obtain the point clouds of a pedestrian bridge structure. Two different point clouds... ver más
Revista: Infrastructures

 
Jiaqi Hu, Yin Gu, Jinhuang Yan, Ying Sun and Xinyi Huang    
With the convenient and fast requirements for construction in bridge engineering, prefabricated assembly technology is widely applied in engineering construction. Typically, prefabricated bridge decks are connected through cast-in-place wet joints. Wet j... ver más
Revista: Applied Sciences