Redirigiendo al acceso original de articulo en 22 segundos...
Inicio  /  Energies  /  Vol: 10 Núm: 10 Par: October (2017)  /  Artículo
ARTÍCULO
TITULO

Solar-Enhanced Air-Cooled Heat Exchangers for Geothermal Power Plants

Kamel Hooman    
Xiaoxue Huang and Fangming Jiang    

Resumen

This paper focuses on the optimization of a Solar-Enhanced Natural-Draft Dry-Cooling Tower (SENDDCT), originally designed by the Queensland Geothermal Energy Centre of Excellence (QGECE), as the air-cooled condenser of a geothermal power plant. The conventional method of heat transfer augmentation through fin-assisted area extension is compared with a metal foam-wrapped tube bundle. Both lead to heat-transfer enhancement, albeit at the expense of a higher pressure drop when compared to the bare tube bundle as our reference case. An optimal design is obtained through the use of a simplified analytical model and existing correlations by maximizing the heat transfer rate with a minimum pressure drop goal as the constraint. Sensitivity analysis was conducted to investigate the effect of sunroof diameter, as well as tube bundle layouts and tube spacing, on the overall performance of the system. Aiming to minimize the flow and thermal resistances for a SENDDCT, an optimum design is presented for an existing tower to be equipped with solar panels to afterheat the air leaving the heat exchanger bundles, which are arranged vertically around the tower skirt. Finally, correlations are proposed to predict the total pressure drop and heat transfer of the extended surfaces considered here.

 Artículos similares

       
 
The ability to model fluid flow and heat transfer in process equipment (e.g., shell-and-tube heat exchangers) is often critical. What is more, many different geometric variants may need to be evaluated during the design process. Although this can be done... ver más
Revista: Energies

 
In-Bok Lee and Seunghee Park    
As part of a preliminary hazard analysis for a new phenol plant, the results of a hazard and operability study (HAZOP) conducted in the initial stages of the project design were re-evaluated due mechanical failure detected during the test operation. Out ... ver más
Revista: Energies

 
Yoshitaka Sakata, Takao Katsura, Katsunori Nagano and Manabu Ishizuka    
Heat advection caused by groundwater flow can potentially improve the performance of a borehole heat exchanger. However, the required flow velocity is not achieved under most natural conditions. This study focuses on artificial groundwater flow generated... ver más
Revista: Hydrology

 
Matthew J. Berry, Caitlin M. Taylor, William King, Y. M. John Chew, Jannis Wenk     Pág. 1 - 18
The mass transfer of ozone and oxygen into water through non-porous membranes was studied using computational fluid dynamics (CFD) modelling and fundamental convection-diffusion theory. Ozone is a gaseous oxidant that is widely applied in drinking water ... ver más
Revista: Water

 
Halil Bayram and Gökhan Sevilgen    
The authors wish to make the following corrections to this paper [1][...]
Revista: Energies