Redirigiendo al acceso original de articulo en 24 segundos...
ARTÍCULO
TITULO

Analysis of the influence of drydock main pumps drive on electric network

Pavel Khristo    

Resumen

The influence of unadjustable-speed AC drive and adjustable-speed DC drive of the drydock main pumps on the network of the Okean shipyard (Ukraine) is investigated in MatLab SimPowerSystems.To accurately simulate deep-bar induction motors, the own method of determining the parameters of the T-shaped equivalent circuit and viscous friction coefficient of a virtual motor according to catalog data is used. This method is based on formulas that correspond to the T-shaped and refined L-shaped equivalent circuit. It is proposed to introduce the corrected values of the initial starting and critical torque ratio into the calculation. The rated power factor is determined indirectly and compared with the catalog value. The dependences of rotor resistance are approximated by elementary functions, which provide almost constant values of these parameters at subcritical slip values.As a result of the simulation, it became clear that even with the alternate starting of unregulated electric pump units, there is a significant voltage drop in the network.The mathematical model of DC drives was built with a common dual-circuit automatic speed control system. A resonance filter is included at the input of each synchronized 6-pulse generator, thereby eliminating possible errors in operation.The simulation results prove that during the operation of DC drives, there are switching voltage variations in the network, substantially non-sinusoidal current consumption and reactive power consumption. Given the stray capacitance of the cable line, high-frequency voltage fluctuations occur, which are dangerous for electric equipment.Through the use of the harmonic filtering and reactive power control device, these negative phenomena can be eliminated, thus, the DC drive will surpass unadjustable-speed induction motor drive in many respects. To minimize reactive power consumption, an automatic control system with an integrated variable gain reactor power controller can be used

 Artículos similares

       
 
Liang Yang, Miaoer Liu, Yun Liu, Tao Zhang, Hailong Lu, Qingzhen Lu and Jun Yan    
A cryogenic hose is used to transport liquefied natural gas at sea, where flexible fittings are sealed by corrugated lining and end flange welding. However, the extreme cryogenic temperatures of the conveyed fluid introduce substantial challenges to the ... ver más

 
Omiros Iatrellis, Nicholas Samaras, Konstantinos Kokkinos and Apostolis Xenakis    
Academic advising is often pivotal in shaping students? educational experiences and choices. This study leverages natural language processing to quantitatively evaluate reviews of academic advisors, aiming to provide actionable insights on key feedback p... ver más

 
Lei Jiang and Ziyue Zeng    
Since the impoundment of the Three Gorges Project, the downstream hydrology and river dynamics have been modified. The Yichang?Chenglingji Reach (YCR), as a part of the mainstream of the Middle Yangtze River, has consequently been significantly scoured, ... ver más
Revista: Water

 
Qirui Bo, Junwei Liu, Wenchang Shang, Ankit Garg, Xiaoru Jia and Kaiyue Sun    
Nowadays, the use of new compound chemical stabilizers to treat marine clay has gained significant attention. However, the complex non-linear relationship between the influencing factors and the unconfined compressive strength of chemically treated marin... ver más

 
Vladimir Pavlinovic, Nikola Foretic, Neven Kovacevic, Tea Galic, Linda Lu?ic Kalcina, Frane Mihanovic and Toni Modric    
This research aimed to identify relations of cognitive and power capacities with reactive agility in pubescent boys (n = 55) and girls (n = 46). Cognitive abilities were evaluated by the Stroop test, while the BlazePod system was used to evaluate agility... ver más
Revista: Applied Sciences