Inicio  /  Applied Sciences  /  Vol: 9 Par: 13 (2019)  /  Artículo
ARTÍCULO
TITULO

Measurement System of Metal Magnetic Memory Method Signals around Rectangular Defects of a Ferromagnetic Pipe

J. Jesús Villegas-Saucillo    
José Javier Díaz-Carmona    
Carlos A. Cerón-Álvarez    
Raúl Juárez-Aguirre    
Saúl M. Domínguez-Nicolás    
Francisco López-Huerta and Agustín L. Herrera-May    

Resumen

Oil and gas pipeline networks require the periodic inspection of their infrastructure, which can cause gas and oil leakage with several damages to the environment and human health. For this, non-destructive testing (NDT) techniques of low-cost and easy implementation are required. An option is the metal magnetic memory (MMM) method, which could be used for real-time monitoring defects of ferromagnetic structures based on the analysis of self-magnetic leakage fields distribution around each defect. This method only requires magnetic sensors with high resolution and a data processing system. We present a measurement system of tangential and normal MMM signals of three rectangular defects of an ASTM A-36 steel pipe. This system is formed by a magnetoresistive sensor, an Arduino nano and a virtual instrumentation. The measured magnetic signals have non-uniform distributions around the rectangular defects, which have small differences with respect to the results obtained of a 2D magnetic dipole model. The size of each rectangular defect is related to the amplitude and shape of its tangential and normal MMM signals. The proposed system could be used for real-time monitoring of the size and location of rectangular defects of ferromagnetic pipes. This system does not require expensive equipment, operators with high skill level or a special treatment of the ferromagnetic samples.

 Artículos similares

       
 
Donghyuk Kum, Jichul Ryu, Yongchul Shin, Jihong Jeon, Jeongho Han, Kyoung Jae Lim and Jonggun Kim    
This study accounted for the importance of daily expansion flow data in compensating for insufficient flow data in a watershed. In particular, the 8-day interval flow measurement data (intermittent monitoring data) could cause uncertainty in the high- or... ver más
Revista: Water

 
Enzhan Zhang, Liang Li, Weiche Huang, Yucheng Jia, Minghu Zhang, Faming Kang and Hu Da    
Large-scale particle image velocimetry (LSPIV) is a computer vision-based technique renowned for its precise and efficient measurement of river surface velocity. However, a crucial prerequisite for utilizing LSPIV involves camera calibration. Conventiona... ver más
Revista: Water

 
Jounghoon Lim, Jinkee Kim and Jong Pal Kim    
A system has been developed to remotely, continuously, and quantitatively measure the physiological activity of trees. The developed tree physiological activity monitoring (TPAM) system is equipped with electrical impedance, temperature, and light intens... ver más
Revista: Applied Sciences

 
Fajia Zheng, Bin Zhang, Yuqiong Zhao, Jiakun Li, Fei Long and Qibo Feng    
Key errors of machine tools have a significant impact on their accuracy, however accurately and quickly measuring the geometric errors of machine tools is essential for key error identification. Fortunately, a quick and direct laser measurement method an... ver más
Revista: Applied Sciences

 
Gokhan Gungor and Mehdi Afshari    
In this study, a sensorimotor controller is designed to characterize the required muscle force to enable a robotics system to perform a human-like circular movement. When the appropriate muscle internal forces are chosen, the arm end-point tracks the des... ver más
Revista: Applied Sciences