Inicio  /  Buildings  /  Vol: 11 Par: 4 (2021)  /  Artículo
ARTÍCULO
TITULO

Shear Strength of HVFA-SCC Beams without Stirrups

Agus Setiya Budi    
Endah Safitri    
Senot Sangadji and Stefanus Adi Kristiawan    

Resumen

Various concretes have been developed to meet the principles of sustainability. High volume fly ash-self compacting concrete (HVFA-SCC) is one example. The utilization of HVFA-SCC for structural applications, however, raises a concern among designers: that HVFA-SCC may not be as strong as conventional concrete when carrying shear forces. This concern is related to slow strength development and relatively smoother crack surface formation in HVFA-SCC, which, consequently, reduces the aggregate interlock mechanism contribution to the shear strength. In this respect, the design code for estimating the shear strength of HVFA-SCC may not be valid for the reason that the code was developed on the basis of the conventional concrete database. Previous research on the shear strength of HVFA-SCC was limited and no database can be extracted to justify the validity of the shear design code. This research was conducted to clarify the suitability of shear design code for HVFA-SCC. The research began with a limited laboratory investigation, followed by a numerical investigation to expand the range of results. Two types of HVFA-SCC beams with dimensions of 100 mm × 150 mm × 1700 mm were prepared, utilizing 50% and 60% fly ash. The shear behavior obtained from the laboratory investigations was then numerically modeled with the help of 3D ATENA Engineering software. The numerical model was used to explore the influence of reinforcement ratio, shear span to beam effective depth ratio, and beam size on the shear strength of the HVFA-SCC beam. The results were compared with the shear strength database of conventional and unconventional concrete beams to judge if the provisions in the design code can be applied to the shear design of an HVFA-SCC beam. The results confirm that the ACI shear design code is applicable for HVFA-SCC.

 Artículos similares

       
 
Hao Wu, Zhezheng Wu, Weimin Song, Dongwei Chen, Mei Yang and Hang Yuan    
Due to the issue of weakened adhesion between ultra-thin surface overlays, higher demands have been placed on bonding layer materials in practical engineering. This study proposed a method for preparing a one-component waterborne epoxy resin-modified emu... ver más
Revista: Buildings

 
Ayman El-Zohairy, Hani Salim, Hesham Shaaban and Mahmoud T. Nawar    
Fatigue in steel?concrete composite beams can result from cyclic loading, causing stress fluctuations that may lead to cumulative damage and eventual failure over an extended period. In this paper, the experimental findings from fatigue loading tests on ... ver más
Revista: Infrastructures

 
Wenbin Zhang, Yan Feng, Xiangqiang Zeng, Ming Xu, Liang Gong and Lijun Rui    
A new type of assembled integral multi-ribbed composite floor system with novel wet joint and steel sleeve connections, which exhibits satisfactory strength and stiffness, was proposed in the previous study. To further study the flexural performances of ... ver más
Revista: Buildings

 
Hao Chai, Xi?an Li, Biao Qin, Weiping Wang and Mani Axel    
The volumetric change in unsaturated loess during loading causes serious damage to the foundation and structure, accompanied by changes in hydraulic conditions. Therefore, quantifying the change in the load effect of loess under hydraulic coupling is of ... ver más
Revista: Water

 
Jian Yang, Ming Sun, Guohuang Yao, Haizhu Guo and Rumian Zhong    
This study explores an advanced prefabricated composite structure, namely ECC/RC composite shear walls with enhanced seismic performance. This performance enhancement is attributed to the strategic use of engineered cementitious composites (ECC) known fo... ver más
Revista: Buildings